Issues and improvements in commercial kitchen exhaust ducts

被引:0
|
作者
Horton, Doug [1 ]
机构
[1] D. J. HORTON, Batavia,IL, United States
来源
Engineered Systems | 2015年 / 32卷 / 01期
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Applicable codes and standards provide requirements for exhaust ducts connected to Type I exhaust hoods. Welded-on-site ducts that are not tested and listed to national consensus standards are hereafter referred to as unlisted ducts. The Minnesota Mechanical Code, in section 506.4.2, requires evaluation of duct leakage by means of an air pressure test. Ducts must hold positive air pressure of 1.0 inch water column for a minimum of 20 minutes unless an equivalent alternate test is specified by the building official. A largely unknown fire risk with leaking kitchen exhaust ducts was discovered by a listing agency conducting a UL Standard 300 test of a prototype fire suppression system. The equipment included a UL 710 listed hood over a natural gas-fueled deep fat fryer. With the exhaust duct pre-heated as required, the deep fat fryer was ignited, and after the specified pre-burn time, the water and surfactant based fire suppression system was activated.
引用
收藏
页码:42 / 49
相关论文
共 50 条
  • [31] THE POTENTIAL FOR CMCS TO REPLACE SUPERALLOYS IN ENGINE EXHAUST DUCTS
    ROTH, R
    CLARK, JP
    FIELD, FR
    JOM-JOURNAL OF THE MINERALS METALS & MATERIALS SOCIETY, 1994, 46 (01): : 32 - 34
  • [32] Propagation of spinning acoustic modes in turbofan exhaust ducts
    Nallasamy, M
    Sutliff, DL
    Heidelberg, LJ
    JOURNAL OF PROPULSION AND POWER, 2000, 16 (05) : 736 - 743
  • [34] Development of a ventilation control system for a commercial kitchen
    Okuda A.
    Kurabuchi T.
    Toriumi Y.
    Nagashima E.
    Journal of Environmental Engineering (Japan), 2019, 84 (758): : 437 - 445
  • [35] 60 Years of Commercial Kitchen Fire Suppression
    Griffin, Bill
    Morgan, Mike
    ASHRAE JOURNAL, 2014, 56 (06) : 48 - 58
  • [36] IMPROVEMENTS TO A COMMERCIAL APPARATUS FOR IMMUNOELECTROPHORESIS
    CONNER, RM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1970, 41 (06): : 875 - &
  • [37] Large filter area ensures clean exhaust air ducts
    Leuderalbert, Jan
    JOT, Journal fuer Oberflaechentechnik, 2022, 62 (09): : 44 - 45
  • [38] Geometry optimization of exhaust ducts applied in thermoelectric cogeneration efficiency
    Gomes, Pedro H. G.
    Calixto, Wesley P.
    Faria, Messias A. A.
    Stecanella, Priscilla A. J.
    Alves, Aylton J.
    Domingues, Elder G.
    2015 IEEE 15TH INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING (IEEE EEEIC 2015), 2015, : 1132 - 1136
  • [39] STEAM TURBINE EXHAUST HOOD WITH SWIRL FLOW SEPARATION DUCTS
    Mizumi, Shunsuke
    Ishibashi, Kouji
    Sawamura, Yasuaki
    PROCEEDINGS OF THE ASME TURBO EXPO 2012, VOL 6, 2012, : 385 - 393
  • [40] Compact exhaust system for commercial vehicles
    Hauber, T.
    ATZ Automobiltechnische Zeitschrift, 2001, 103 (4 SPEC. ISS.) : 26 - 28