Issues and improvements in commercial kitchen exhaust ducts

被引:0
|
作者
Horton, Doug [1 ]
机构
[1] D. J. HORTON, Batavia,IL, United States
来源
Engineered Systems | 2015年 / 32卷 / 01期
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Applicable codes and standards provide requirements for exhaust ducts connected to Type I exhaust hoods. Welded-on-site ducts that are not tested and listed to national consensus standards are hereafter referred to as unlisted ducts. The Minnesota Mechanical Code, in section 506.4.2, requires evaluation of duct leakage by means of an air pressure test. Ducts must hold positive air pressure of 1.0 inch water column for a minimum of 20 minutes unless an equivalent alternate test is specified by the building official. A largely unknown fire risk with leaking kitchen exhaust ducts was discovered by a listing agency conducting a UL Standard 300 test of a prototype fire suppression system. The equipment included a UL 710 listed hood over a natural gas-fueled deep fat fryer. With the exhaust duct pre-heated as required, the deep fat fryer was ignited, and after the specified pre-burn time, the water and surfactant based fire suppression system was activated.
引用
收藏
页码:42 / 49
相关论文
共 50 条
  • [21] Kitchen and Toilet of the Residence Exhaust Flow Field Analysis
    wang, Yueren
    Xue, Cong
    Zhang, Jing
    PROGRESS IN POWER AND ELECTRICAL ENGINEERING, PTS 1 AND 2, 2012, 354-355 : 726 - 731
  • [22] Commercial Kitchen Fire Suppression Solutions
    Griffin, Bill
    Morgan, Mike
    ASHRAE JOURNAL, 2016, 58 (11) : 14 - +
  • [23] Commercial Kitchen Ventilation Fire Mitigation
    Melink, Stephen K.
    ASHRAE JOURNAL, 2015, 57 (05) : 16 - +
  • [24] Design Considerations for Commercial Kitchen Ventilation
    Clark, John A.
    ASHRAE JOURNAL, 2012, 54 (02) : 54 - +
  • [25] The control of air quality in commercial kitchen
    Xing, J
    Jin, Y
    You, S
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 3640 - 3644
  • [26] The novel design concept for commercial kitchen
    Kosonen, R
    Hagström, K
    Laine, T
    PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, : 977 - 984
  • [27] SIZING A FEEDER FOR COMMERCIAL KITCHEN EQUIPMENT
    不详
    EC&M-ELECTRICAL CONSTRUCTION AND MAINTENANCE, 1983, 82 (06): : 52 - 52
  • [28] Commercial kitchen ventilation: The design challenge!
    Fisher-Nickel, Inc.
    不详
    Eng syst, 2007, 5 (36-44):
  • [29] Particle capture by a rotating disk in a kitchen exhaust hood
    Zhang, Shiyu
    Liu, Sumei
    Chen, Qingyan
    AEROSOL SCIENCE AND TECHNOLOGY, 2020, 54 (08) : 929 - 940
  • [30] Characterization of rasping noise in automotive engine exhaust ducts
    Ayadi, M
    Frikha, S
    Hennion, PY
    JOURNAL OF SOUND AND VIBRATION, 2001, 244 (01) : 79 - 106