Applicable codes and standards provide requirements for exhaust ducts connected to Type I exhaust hoods. Welded-on-site ducts that are not tested and listed to national consensus standards are hereafter referred to as unlisted ducts. The Minnesota Mechanical Code, in section 506.4.2, requires evaluation of duct leakage by means of an air pressure test. Ducts must hold positive air pressure of 1.0 inch water column for a minimum of 20 minutes unless an equivalent alternate test is specified by the building official. A largely unknown fire risk with leaking kitchen exhaust ducts was discovered by a listing agency conducting a UL Standard 300 test of a prototype fire suppression system. The equipment included a UL 710 listed hood over a natural gas-fueled deep fat fryer. With the exhaust duct pre-heated as required, the deep fat fryer was ignited, and after the specified pre-burn time, the water and surfactant based fire suppression system was activated.
引用
收藏
页码:42 / 49
相关论文
共 50 条
  • [1] Kitchen exhaust: Issues and solutions
    Clark, JA
    ASHRAE JOURNAL, 2001, 43 (10) : 37 - 39
  • [2] Test Analysis on Flow Field of Exhaust Hood in Commercial Kitchen
    Jiang, Dahua
    Li, Angui
    Shi, Faen
    Zhao, Yujiao
    SUSTAINABLE DEVELOPMENT OF URBAN ENVIRONMENT AND BUILDING MATERIAL, PTS 1-4, 2012, 374-377 : 560 - +
  • [3] DETERMINING THE NET AIR VOLUME REQUIRED FOR COMMERCIAL KITCHEN EXHAUST
    BLACK, D
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1983, 25 (12): : 76 - 76
  • [4] Survey study on Chinese commercial kitchen exhaust fume systems in Tianjin
    Zhang, Awen
    Deng, Na
    Shen, Changyu
    Hao, Ruisen
    Liu, Junjie
    Wang, Yonghong
    Long, Zhengwei
    BUILDING AND ENVIRONMENT, 2020, 171
  • [5] Survey study on Chinese commercial kitchen exhaust fume systems in Tianjin
    Zhang, Awen
    Deng, Na
    Shen, Changyu
    Hao, Ruisen
    Liu, Junjie
    Wang, Yonghong
    Long, Zhengwei
    Building and Environment, 2021, 171
  • [6] Performance Evaluation of Handheld Airflow Instruments Applied to Commercial Kitchen Exhaust Systems
    Kuehn, Thomas H.
    Olson, Bernard A.
    Campbell, Kevin
    Hawkinson, Andrew J.
    ASHRAE: TRANSACTIONS 2011, VOL 117, PT 1, 2011, 117 : 690 - 701
  • [7] DETERMINING THE NET AIR VOLUME REQUIRED FOR COMMERCIAL KITCHEN EXHAUST SYSTEMS.
    Black, David K.
    Building Standards, 1985, 54 (04): : 20 - 23
  • [8] Utilization of waste heat from commercial kitchen exhaust for water heating and dish drying
    Wang, Yuan
    Shen, Chao
    Sun, Pengyi
    Li, Chengyao
    Zhang, Chunxiao
    JOURNAL OF BUILDING ENGINEERING, 2020, 32
  • [9] Numerical Simulation of IAQ under Up-suction Exhaust Hood in Commercial Kitchen
    Jiang, Dahua
    Li, Angui
    Shi, Faen
    Wang, Zhihua
    ADVANCED BUILDING MATERIALS, PTS 1-4, 2011, 250-253 (1-4): : 3228 - +
  • [10] New rules for kitchen exhaust
    Gerstler, WD
    ASHRAE JOURNAL, 2002, 44 (11) : 26 - +