Booster heat pump with drop-in zeotropic mixtures applied in ultra-low temperature district heating system

被引:2
|
作者
Zhu, Tingting [1 ,2 ]
Vieren, Elias [3 ]
Liang, Jierong [1 ,4 ]
Thorsen, Jan Eric [5 ]
De Paepe, Michel [3 ,6 ]
Lecompte, Steven [3 ,6 ]
Elmegaard, Brian [1 ]
机构
[1] Tech Univ Denmark, Dept Civil & Mech Engn, DK-2800 Lyngby, Denmark
[2] Univ Twente, Dept Thermal & Fluid Engn, NL-7522 NB Enschede, Netherlands
[3] Univ Ghent, Dept Electromech Syst & Met Engn, B-9000 Ghent, Belgium
[4] MAGNOTHERM Solut GmbH, Pfungstadter Str 102, D-64297 Darmstadt, Germany
[5] Danfoss A S, Nordborg, Denmark
[6] FlandersMake, UGENT Core Lab, EEDT MP, B-3000 Leuven, Belgium
关键词
Booster heat pump; District heating; Zeotropic mixture; Domestic hot water; Exergetic efficiency; REFRIGERANTS; PERFORMANCE;
D O I
10.1016/j.energy.2024.132292
中图分类号
O414.1 [热力学];
学科分类号
摘要
The pursuit of sustainable district heating solutions has driven a growing interest in ultra-low temperature district heating (ULTDH) systems, where booster heat pumps (BHPs) play a pivotal role despite challenges posed by their efficiency limitations under large temperature glide conditions. This paper investigates the potential of drop-in R-1234yf/R-32 zeotropic mixtures in BHPs compared to a baseline R-134a system, within the context of a ULTDH framework. This study focused on the viability of the mixtures of R-1234yf/R-32 with the composition ratio of 80 %/20 % and 90 %/10 %. The investigation reveals disparities in compressor efficiency and heat exchanger pressure drop at the component level. Device-level analysis unveils increased COP for R-1234yf/R-32 mixtures, alongside with maximum second-law efficiencies reaching 0.32. A remarkable enhancement in heating capacity up to 58 % was found. System-level analysis demonstrated exergetic efficiencies and identified preferable district heating temperatures. Exergetic efficiencies of 0.47, 0.55, and 0.59 were achieved for domestic hot water preparation at district heating supply temperatures of 30 degrees C, 35 degrees C, and 40 degrees C, with a subsequent shift in optimal district heating temperatures as central heating station efficiency decreased. Temperature profile analysis underscored challenges stemming from excessive subcooling, highlighting the need for configuration refinements.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Model predictive control for demand response of domestic hot water preparation in ultra-low temperature district heating systems
    Knudsen, Michael Dahl
    Petersen, Steffen
    ENERGY AND BUILDINGS, 2017, 146 : 55 - 64
  • [42] Investigating control strategies for a domestic low-temperature heat pump heating system
    Sakellari, D.
    Forsen, M.
    Lundqvist, P.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2006, 29 (04): : 547 - 555
  • [43] Low Temperature Hydronic Heating System with Radiators and Geothermal Ground Source Heat Pump
    Banjac, Milos
    Vasiljevic, Bogosav
    Gojak, Milan
    FME TRANSACTIONS, 2007, 35 (03): : 129 - 134
  • [44] Suitability Analysis of the Heating Method of Low Temperature Air Source Heat Pump Applied in North China
    Zhang Qunli
    Zhang Lin
    Li Yinlong
    8TH INTERNATIONAL CONFERENCE ON APPLIED ENERGY (ICAE2016), 2017, 105 : 2569 - 2574
  • [45] Thermodynamic analysis of a dual-pressure evaporation high-temperature heat pump with low GWP zeotropic mixtures for steam generation
    Feng, Chunyu
    Guo, Cong
    Chen, Junbin
    Tan, Sicong
    Jiang, Yuyan
    ENERGY, 2024, 294
  • [46] Study on the Performance of a New Ultra-Low Temperature Air Source Heat Pump (ASHP) Unit in Cold Regions
    Di, Yanqiang
    Zhao, Chen
    Lian, Xueli
    Li, Xiaolong
    Bao, Daorina
    Liu, Jinxing
    BUILDINGS, 2023, 13 (08)
  • [47] Analysis of Zeotropic mixtures used in double circulation low-temperature waste heat recovery system with screw expander
    Tan, X. (txf_385@163.com), 1600, Editorial Office of Chinese Journal of Mechanical Engineering (48):
  • [48] Thermodynamic analysis and parametric optimization of ejector heat pump integrated with organic Rankine cycle combined cooling, heating and power system using zeotropic mixtures
    Zhu, Yilin
    Li, Weiyi
    Wang, Yongzhen
    Li, Haojie
    Li, Shuai
    APPLIED THERMAL ENGINEERING, 2021, 194
  • [49] Energy & economic assessment of facade-integrated solar thermal systems combined with ultra-low temperature district-heating
    Lumbreras, Mikel
    Garay, Roberto
    RENEWABLE ENERGY, 2020, 159 : 1000 - 1014
  • [50] Low-temperature waste heat enabling abandoning coal in Espoo district heating system
    Hiltunen, Pauli
    Syri, Sanna