Booster heat pump with drop-in zeotropic mixtures applied in ultra-low temperature district heating system

被引:2
|
作者
Zhu, Tingting [1 ,2 ]
Vieren, Elias [3 ]
Liang, Jierong [1 ,4 ]
Thorsen, Jan Eric [5 ]
De Paepe, Michel [3 ,6 ]
Lecompte, Steven [3 ,6 ]
Elmegaard, Brian [1 ]
机构
[1] Tech Univ Denmark, Dept Civil & Mech Engn, DK-2800 Lyngby, Denmark
[2] Univ Twente, Dept Thermal & Fluid Engn, NL-7522 NB Enschede, Netherlands
[3] Univ Ghent, Dept Electromech Syst & Met Engn, B-9000 Ghent, Belgium
[4] MAGNOTHERM Solut GmbH, Pfungstadter Str 102, D-64297 Darmstadt, Germany
[5] Danfoss A S, Nordborg, Denmark
[6] FlandersMake, UGENT Core Lab, EEDT MP, B-3000 Leuven, Belgium
关键词
Booster heat pump; District heating; Zeotropic mixture; Domestic hot water; Exergetic efficiency; REFRIGERANTS; PERFORMANCE;
D O I
10.1016/j.energy.2024.132292
中图分类号
O414.1 [热力学];
学科分类号
摘要
The pursuit of sustainable district heating solutions has driven a growing interest in ultra-low temperature district heating (ULTDH) systems, where booster heat pumps (BHPs) play a pivotal role despite challenges posed by their efficiency limitations under large temperature glide conditions. This paper investigates the potential of drop-in R-1234yf/R-32 zeotropic mixtures in BHPs compared to a baseline R-134a system, within the context of a ULTDH framework. This study focused on the viability of the mixtures of R-1234yf/R-32 with the composition ratio of 80 %/20 % and 90 %/10 %. The investigation reveals disparities in compressor efficiency and heat exchanger pressure drop at the component level. Device-level analysis unveils increased COP for R-1234yf/R-32 mixtures, alongside with maximum second-law efficiencies reaching 0.32. A remarkable enhancement in heating capacity up to 58 % was found. System-level analysis demonstrated exergetic efficiencies and identified preferable district heating temperatures. Exergetic efficiencies of 0.47, 0.55, and 0.59 were achieved for domestic hot water preparation at district heating supply temperatures of 30 degrees C, 35 degrees C, and 40 degrees C, with a subsequent shift in optimal district heating temperatures as central heating station efficiency decreased. Temperature profile analysis underscored challenges stemming from excessive subcooling, highlighting the need for configuration refinements.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Analysis of the dilatancy technology of district heating system with high-temperature heat pump
    Wang Ying
    Zhang Yufeng
    ENERGY AND BUILDINGS, 2012, 47 : 230 - 236
  • [32] Simulation of Unglazed Solar Thermal Systems Integrated into Facade & Combined with Ultra-Low Temperature District Heating
    Lumbreras, Mikel
    Garay, Roberto
    PROCEEDINGS OF BUILDING SIMULATION 2019: 16TH CONFERENCE OF IBPSA, 2020, : 4401 - 4408
  • [33] Analysis of low temperature lift heat pump application in a district heating system for flue gas condenser efficiency improvement
    Zajacs, Aleksandrs
    Bogdanovics, Raimonds
    Borodinecs, Anatolijs
    SUSTAINABLE CITIES AND SOCIETY, 2020, 57
  • [34] Thermodynamic analysis of evaporation temperature glide of zeotropic mixtures on the ORC-CCHP system integrated with ejector and heat pump
    Zhu, Yilin
    Li, Weiyi
    Sun, Guanzhong
    INNOVATIVE SOLUTIONS FOR ENERGY TRANSITIONS, 2019, 158 : 1632 - 1639
  • [35] Analysis and experiment of dilatancy technology of district heating system with high-temperature heat pump
    Wang, Ying
    Zhang, Yu-Feng
    Zhang, Y.-F. (yufengfa@tju.edu.cn), 2012, Tianjin University (45): : 981 - 986
  • [36] Economic feasibility of ultra-low temperature district heating systems in newly built areas supplied by renewable energy
    Meesenburg, Wiebke
    Ommen, Torben
    Thorsen, Jan Eric
    Elmegaard, Brian
    ENERGY, 2020, 191
  • [37] Emergy analysis and optimization for a solar-driven heating and cooling system integrated with air source heat pump in the ultra-low energy building
    Wang, Jiazheng
    Xu, Shuxue
    Ma, Guoyuan
    Gou, Qianqian
    Zhao, Pu
    Jia, Xiaoya
    JOURNAL OF BUILDING ENGINEERING, 2023, 63
  • [38] Ultra-low temperature heating system based on dual-source solar assisted heat pump using compound parabolic concentrator-capillary tube solar collector
    Yang, Li Wei
    Pu, Jin Huan
    Xu, Rong Ji
    Yang, Tong
    Wang, Hua Sheng
    ENERGY AND BUILDINGS, 2024, 324
  • [39] Organic Rankine cycle-ejector heat pump hybrid system using low GWP zeotropic mixtures for trigeneration application
    Yaici, Wahiba
    Entchev, Evgueniy
    Longo, Michela
    ENERGY CONVERSION AND MANAGEMENT, 2024, 299
  • [40] Experimental Study on the Performance of ORC System Based on Ultra-Low Temperature Heat Sources
    Zhou T.
    Hao L.
    Xu X.
    Si M.
    Zhang L.
    Energy Engineering: Journal of the Association of Energy Engineering, 2024, 121 (01): : 145 - 168