Booster heat pump with drop-in zeotropic mixtures applied in ultra-low temperature district heating system

被引:2
|
作者
Zhu, Tingting [1 ,2 ]
Vieren, Elias [3 ]
Liang, Jierong [1 ,4 ]
Thorsen, Jan Eric [5 ]
De Paepe, Michel [3 ,6 ]
Lecompte, Steven [3 ,6 ]
Elmegaard, Brian [1 ]
机构
[1] Tech Univ Denmark, Dept Civil & Mech Engn, DK-2800 Lyngby, Denmark
[2] Univ Twente, Dept Thermal & Fluid Engn, NL-7522 NB Enschede, Netherlands
[3] Univ Ghent, Dept Electromech Syst & Met Engn, B-9000 Ghent, Belgium
[4] MAGNOTHERM Solut GmbH, Pfungstadter Str 102, D-64297 Darmstadt, Germany
[5] Danfoss A S, Nordborg, Denmark
[6] FlandersMake, UGENT Core Lab, EEDT MP, B-3000 Leuven, Belgium
关键词
Booster heat pump; District heating; Zeotropic mixture; Domestic hot water; Exergetic efficiency; REFRIGERANTS; PERFORMANCE;
D O I
10.1016/j.energy.2024.132292
中图分类号
O414.1 [热力学];
学科分类号
摘要
The pursuit of sustainable district heating solutions has driven a growing interest in ultra-low temperature district heating (ULTDH) systems, where booster heat pumps (BHPs) play a pivotal role despite challenges posed by their efficiency limitations under large temperature glide conditions. This paper investigates the potential of drop-in R-1234yf/R-32 zeotropic mixtures in BHPs compared to a baseline R-134a system, within the context of a ULTDH framework. This study focused on the viability of the mixtures of R-1234yf/R-32 with the composition ratio of 80 %/20 % and 90 %/10 %. The investigation reveals disparities in compressor efficiency and heat exchanger pressure drop at the component level. Device-level analysis unveils increased COP for R-1234yf/R-32 mixtures, alongside with maximum second-law efficiencies reaching 0.32. A remarkable enhancement in heating capacity up to 58 % was found. System-level analysis demonstrated exergetic efficiencies and identified preferable district heating temperatures. Exergetic efficiencies of 0.47, 0.55, and 0.59 were achieved for domestic hot water preparation at district heating supply temperatures of 30 degrees C, 35 degrees C, and 40 degrees C, with a subsequent shift in optimal district heating temperatures as central heating station efficiency decreased. Temperature profile analysis underscored challenges stemming from excessive subcooling, highlighting the need for configuration refinements.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Exergy analysis of the performance of low-temperature district heating system with geothermal heat pump
    Sekret, Robert
    Nitkiewicz, Anna
    ARCHIVES OF THERMODYNAMICS, 2014, 35 (01) : 77 - 86
  • [22] HIGH-TEMPERATURE HEAT PUMP INTEGRATION INTO DISTRICT HEATING SYSTEM
    Jakovleva, Ludmila
    20TH INTERNATIONAL SCIENTIFIC CONFERENCE ENGINEERING FOR RURAL DEVELOPMENT, 2021, : 1312 - 1316
  • [23] Thermodynamic analysis of a modified cascade high temperature heat pump with zeotropic mixtures for heating production up to 200 °C
    Huang, Yisheng
    Li, Guiqiang
    Tang, Xin
    Huang, Kunteng
    Zhao, Wei
    Zhang, Jing
    ENERGY CONVERSION AND MANAGEMENT, 2025, 324
  • [24] Energy and economic simulation of a renewable energy community applied to a new generation ultra-low temperature district heating and cooling network
    Romagnosi, Michela
    Aprile, Marcello
    Denare, Alice
    53RD AICARR INTERNATIONAL CONFERENCE FROM NZEB TO ZEB: THE BUILDINGS OF THE NEXT DECADES FOR A HEALTHY AND SUSTAINABLE FUTURE, 2024, 523
  • [25] Low and Ultra-Low Temperature District Heating Equipped by Heat Pumps-An Analysis of the Best Operative Conditions for a Swiss Case Study
    Toffanin, Riccardo
    Caputo, Paola
    Belliardi, Marco
    Curti, Vinicio
    ENERGIES, 2022, 15 (09)
  • [26] Comparison of traditional district heating with low temperature district heating systems featuring organic Rankine cycle and heat pump
    Mikielewicz, Jaros law
    Mikielewicz, Dariusz
    ENERGY, 2023, 281
  • [27] Influence of supply temperature and booster technology on the energetic performance and levelized cost of heat of a district heating network with central heat pump
    Degelin, A.
    Tassenoy, R.
    Vieren, E.
    Demeester, T.
    T'Jollyn, I.
    De Paepe, M.
    ENERGY, 2024, 312
  • [28] Simulation Study on Characteristics of Ultra-low Temperature Heat Pump Air Conditioning System for Pure Electric Vehicles
    Li, Haijun
    Zhou, Guang-Hui
    Li, An-Gui
    Li, Xu-Ge
    Chen, Jie
    Chen, Tong
    ADVANCES IN CIVIL AND INDUSTRIAL ENGINEERING IV, 2014, 580-583 : 2475 - +
  • [29] Temperature drop of heating fluid as a primary condition for effective utilization of low-grade heat using flash cycles and zeotropic mixtures in refrigeration ejector systems
    Jakonczuk, Pawel
    Smierciew, Kamil
    Zou, Huiming
    Butrymowicz, Dariusz
    Dudar, Adam
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2025, 47 (01) : 4621 - 4639
  • [30] Temperature drop of heating fluid as a primary condition for effective utilization of low-grade heat using flash cycles and zeotropic mixtures in refrigeration ejector systems
    Jakonczuk, Pawel
    Smierciew, Kamil
    Zou, Huiming
    Butrymowicz, Dariusz
    Dudar, Adam
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2025, 47 (01) : 4621 - 4639