Accuracy, Time, and Comfort of Different Intraoral Scanners: An In Vivo Comparison Study

被引:0
|
作者
Lione, Roberta [1 ]
De Razza, Francesca Chiara [1 ]
Gazzani, Francesca [1 ]
Lugli, Letizia [1 ]
Cozza, Paola [1 ]
Pavoni, Chiara [1 ]
机构
[1] UniCamillus St Camillus Int Med Univ, Dept Hlth Sci, Rome, Italy
来源
APPLIED SCIENCES-BASEL | 2024年 / 14卷 / 17期
关键词
digital dentistry; digital cast analysis; clinical practice; digital impressions; IMPRESSION TECHNIQUES;
D O I
10.3390/app14177731
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Background: The purpose of this study was to compare the accuracy of three different intraoral scanners (IOSs) and to evaluate the patients' experience. Methods: Thirty subjects were scanned with three different IOSs (TRIOS Color (R), iTero Element 5D (R), and iTero Lumina (R)): a sample of 90 maxillary casts was collected. The inclusion criteria were permanent dentition, absence of defects during the dental impression, and complete record of the palatal vault. After the scanning procedure, patients were asked to answer a questionnaire (10 answers, scale from 1 to 10) to compare their experiences with iTero Element and iTero Lumina in the scanning procedure. Results: Differences were recorded in the upper central incisor region (f-ratio of 4.186 for Mesiodistal 1.1 and f-ratio of 4.222 for Mesiodistal 2.1, p < 0.05), while intercanine width Upper 13-23 showed the smallest f-ratio (0.226) when compared to the other results, followed by Mesiodistal 1.4 (0.433). Patients reported more comfort, less pain, decreased duration, and a better technology visualization of the impression with iTero Lumina. No significant differences concerning dryness of the mouth and gag reflex were found. Conclusions: The examined IOSs offer comparable accuracy in capturing dental arch dimensions. The interviewed patients expressed an overall preference for digital impressions performed with iTero Lumina, linked to increased comfort, painless practice, and a better technology visualization of the impression.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] In vivo full-arch accuracy of intraoral scanners: a narrative review
    Jennes, Marie-Elise
    Soetebeer, Maren
    Beuer, Florian
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2022, 25 (01) : 9 - 16
  • [22] Accuracy of intraoral scans: An in vivo study of different scanning devices
    Kernen, Florian
    Schlager, Stefan
    Alvarez, Veronica Seidel
    Mehrhof, Juergen
    Vach, Kirstin
    Kohal, Ralf
    Nelson, Katja
    Fluegge, Tabea
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (06): : 1303 - 1309
  • [23] Comparative analysis of intraoral scanners accuracy using 3D software: an in vivo study
    Federica Pellitteri
    Paolo Albertini
    Angelica Vogrig
    Giorgio Alfredo Spedicato
    Giuseppe Siciliani
    Luca Lombardo
    Progress in Orthodontics, 23
  • [24] Comparative analysis of intraoral scanners accuracy using 3D software: an in vivo study
    Pellitteri, Federica
    Albertini, Paolo
    Vogrig, Angelica
    Spedicato, Giorgio Alfredo
    Siciliani, Giuseppe
    Lombardo, Luca
    PROGRESS IN ORTHODONTICS, 2022, 23 (01)
  • [25] Accuracy of intraoral scans of edentulous jaws with different generations of intraoral scanners compared to laboratory scans
    Kontis, Panagiotis
    Gueth, Jan-Frederik
    Schubert, Oliver
    Keul, Christine
    JOURNAL OF ADVANCED PROSTHODONTICS, 2021, 13 (05): : 316 - 326
  • [26] Influence of Preparation Type and Tooth Geometry on the Accuracy of Different Intraoral Scanners
    Ashraf, Yasmine
    Sabet, Ahmed
    Hamdy, Amina
    Ebeid, Kamal
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2020, 29 (09): : 800 - 804
  • [27] In Vitro Comparison of the Accuracy of Conventional Impression and Four Intraoral Scanners in Four Different Implant Impression Scenarios
    Alpkilic, Dilara Seyma
    Deger, Sabire Isler
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (01) : 39 - 48
  • [28] Evaluation and comparison of the accuracy of three intraoral scanners for replicating a complete denture
    Le Texier, Louise
    Nicolas, Emmanuel
    Batisse, Cindy
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (04): : 706.e1 - 706.e8
  • [29] Accuracy and precision of 3 intraoral scanners and accuracy of conventional impressions: A novel in vivo analysis method
    Nedelcu, R.
    Olsson, P.
    Nystrom, I.
    Ryden, J.
    Thor, A.
    JOURNAL OF DENTISTRY, 2018, 69 : 110 - 118
  • [30] Accuracy evaluation of two different intraoral scanners in implant prosthodontics. A comparative in vitro study
    Verniani, G.
    Casucci, A.
    Nosrati, N.
    D'Arienzo, L. F.
    Val, M.
    Cagidiaco, E. Ferrari
    JOURNAL OF OSSEOINTEGRATION, 2024, 16 (01) : 61 - 64