Evaluation and comparison of the accuracy of three intraoral scanners for replicating a complete denture

被引:2
|
作者
Le Texier, Louise [1 ]
Nicolas, Emmanuel [1 ]
Batisse, Cindy [2 ,3 ]
机构
[1] Univ Clermont Auvergne, Fac Odontol, Dept Odontol, Clermont Ferrand, France
[2] Univ Clermont Auvergne, Fac Odontol, Prosthet Dept, Clermont Ferrand, France
[3] Univ Clermont Auvergne, CROC, 2 Rue Braga, F-63000 Clermont Ferrand, France
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2024年 / 131卷 / 04期
关键词
PRECISION;
D O I
10.1016/j.prosdent.2024.01.011
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Technological advances in digital acquisition tools have increased the scope of intraoral scanners (IOSs), including scanning a removable complete denture (RCD) to replicate it. However, studies assessing the accuracy of IOSs for replicating a maxillary or mandibular RCD are lacking. Purpose. The purpose of this in vitro study was to evaluate the accuracy (trueness and precision) of 3 IOSs while replicating a maxillary and mandibular RCD. Material and methods. One maxillary and 1 mandibular RCD were scanned with a desktop scanner (D2000) to obtain the reference model. Two operators scanned each RCD 5 times with 3 different IOSs (TRIOS 4, Primescan, and IS3800), following a predefined acquisition protocol. The 60 study models obtained were compared with the reference model using the Geomagic software program. For each comparison, the mean and standard deviation of discrepancy were calculated. Distances were measured on both the reference and the study model, and differences were calculated to assess whether sagittal or transverse deformations were present. The tolerance percentage of the volume of the digital model compared with the volume of the reference model was determined (difference tolerance was set at 0.1 mm). A univariate analysis of variance followed by a post hoc analysis using the Student-Newman-Keuls (alpha=.05) test was performed to determine the truest and the most precise IOS. Results. The TRIOS 4 and Primescan IOSs had comparable trueness, with mean dimensional variations of 47 +/- 27 mu m and 57 +/- 8 mu m respectively compared with the reference model. The IS3800 had a lower trueness (98 +/- 35 mu m). Primescan was significantly more precise with a mean standard deviation of 64 +/- 15 mu m (P<.05). The TRIOS 4 (141 +/- 48 <mu>m) and IS3800 (129 +/- 24 mu m) had comparable precision. Primescan showed the least sagittal and transverse deformation. Conclusions. This study determined that an RCD can be replicated using an IOS, although all IOSs did not have equal accuracy. An in vivo study needs to assess whether this procedure is clinically acceptable.
引用
收藏
页码:706.e1 / 706.e8
页数:8
相关论文
共 50 条
  • [1] Complete-arch accuracy of intraoral scanners
    Treesh, Joshua C.
    Liacouras, Peter C.
    Taft, Robert M.
    Brooks, Daniel, I
    Raiciulescu, Sorana
    Ellert, Daniel O.
    Grant, Gerald T.
    Ye, Ling
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 120 (03): : 382 - 388
  • [2] A comparison of the accuracy of intraoral scanners using an intraoral environment simulator
    Park, Hye-Nan
    Lim, Young-Jun
    Yi, Won-Jin
    Han, Jung-Suk
    Lee, Seung-Pyo
    JOURNAL OF ADVANCED PROSTHODONTICS, 2018, 10 (01): : 58 - 64
  • [3] Accuracy of Intraoral Scanners for Recording the Denture Bearing Areas: A Systematic Review
    Rasaie, Vanya
    Abduo, Jaafar
    Hashemi, Saloumeh
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2021, 30 (06): : 520 - 539
  • [4] Comparison of Accuracy of Current Ten Intraoral Scanners
    Amornvit, Pokpong
    Rokaya, Dinesh
    Sanohkan, Sasiwimol
    BIOMED RESEARCH INTERNATIONAL, 2021, 2021
  • [5] Accuracy of intraoral scanners in different complete arch scan patterns
    Pattamavilai, Sakaorat
    Ongthiemsak, Chakree
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (01): : 155 - 162
  • [6] Quantitative and qualitative evaluation on the accuracy of three intraoral scanners for human identification in forensic odontology
    Bae, Eun-Jeong
    Woo, Eun-Jin
    ANATOMY & CELL BIOLOGY, 2022, 55 (01) : 72 - 78
  • [7] Accuracy of 9 intraoral scanners for complete-arch image acquisition: A qualitative and quantitative evaluation
    Kim, Ryan Jin-Young
    Park, Ji-Man
    Shim, June-Sung
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 120 (06): : 895 - +
  • [8] In vitro comparison of five desktop scanners and an industrial scanner in the evaluation of an intraoral scanner accuracy
    Borbola, Daniel
    Berkei, Gabor
    Simon, Botond
    Romanszky, Laszlo
    Sersli, Gyorgy
    DeFee, Michael
    Renne, Walter
    Mangano, Francesco
    Vag, Janos
    JOURNAL OF DENTISTRY, 2023, 129
  • [9] Evaluation of the accuracy of seven intraoral scanners for the full dentate and partially edentulous complete-arch mandibular casts: An in vitro comparison
    Wang, Xin
    Zhang, Fang
    Ma, Dan
    Ye, Xiaolan
    Zheng, Xiaojuan
    Ren, Ruifang
    Ren, Nan
    Bai, Shizhu
    HELIYON, 2024, 10 (10)
  • [10] Complete-Arch Accuracy of Four Intraoral Scanners: An In Vitro Study
    Celeghin, Giordano
    Franceschetti, Giulio
    Mobilio, Nicola
    Fasiol, Alberto
    Catapano, Santo
    Corsalini, Massimo
    Grande, Francesco
    HEALTHCARE, 2021, 9 (03)