Accuracy, Time, and Comfort of Different Intraoral Scanners: An In Vivo Comparison Study

被引:0
|
作者
Lione, Roberta [1 ]
De Razza, Francesca Chiara [1 ]
Gazzani, Francesca [1 ]
Lugli, Letizia [1 ]
Cozza, Paola [1 ]
Pavoni, Chiara [1 ]
机构
[1] UniCamillus St Camillus Int Med Univ, Dept Hlth Sci, Rome, Italy
来源
APPLIED SCIENCES-BASEL | 2024年 / 14卷 / 17期
关键词
digital dentistry; digital cast analysis; clinical practice; digital impressions; IMPRESSION TECHNIQUES;
D O I
10.3390/app14177731
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Background: The purpose of this study was to compare the accuracy of three different intraoral scanners (IOSs) and to evaluate the patients' experience. Methods: Thirty subjects were scanned with three different IOSs (TRIOS Color (R), iTero Element 5D (R), and iTero Lumina (R)): a sample of 90 maxillary casts was collected. The inclusion criteria were permanent dentition, absence of defects during the dental impression, and complete record of the palatal vault. After the scanning procedure, patients were asked to answer a questionnaire (10 answers, scale from 1 to 10) to compare their experiences with iTero Element and iTero Lumina in the scanning procedure. Results: Differences were recorded in the upper central incisor region (f-ratio of 4.186 for Mesiodistal 1.1 and f-ratio of 4.222 for Mesiodistal 2.1, p < 0.05), while intercanine width Upper 13-23 showed the smallest f-ratio (0.226) when compared to the other results, followed by Mesiodistal 1.4 (0.433). Patients reported more comfort, less pain, decreased duration, and a better technology visualization of the impression with iTero Lumina. No significant differences concerning dryness of the mouth and gag reflex were found. Conclusions: The examined IOSs offer comparable accuracy in capturing dental arch dimensions. The interviewed patients expressed an overall preference for digital impressions performed with iTero Lumina, linked to increased comfort, painless practice, and a better technology visualization of the impression.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Complete-arch accuracy of intraoral scanners
    Treesh, Joshua C.
    Liacouras, Peter C.
    Taft, Robert M.
    Brooks, Daniel, I
    Raiciulescu, Sorana
    Ellert, Daniel O.
    Grant, Gerald T.
    Ye, Ling
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 120 (03): : 382 - 388
  • [42] The impact of software updates on accuracy of intraoral scanners
    Schmalzl, Judit
    Roth, Ivett
    Borbely, Judit
    Hermann, Peter
    Vecsei, Balint
    BMC ORAL HEALTH, 2023, 23 (01)
  • [43] Accuracy and Reliability of Intraoral Scanners: Are They the Better Option?
    Ebeid K.
    Salah T.
    Nossair S.
    Current Oral Health Reports, 2017, 4 (3) : 209 - 214
  • [44] Full-arch accuracy of five intraoral scanners: In vivo analysis of trueness and precision
    Kwon, Miran
    Cho, Youngmok
    Kim, Dong-Wook
    Kim, MyungSu
    Kim, Yoon-Ji
    Chang, Minho
    KOREAN JOURNAL OF ORTHODONTICS, 2021, 51 (02) : 95 - 104
  • [45] Influence of Liquid on the Tooth Surface on the Accuracy of Intraoral Scanners: An In Vitro Study
    Chen, Yuming
    Zhai, Zhihao
    Li, Hefei
    Yamada, Shuhei
    Matsuoka, Takashi
    Ono, Shinji
    Nakano, Tamaki
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (01): : 59 - 64
  • [46] Complete-Arch Accuracy of Four Intraoral Scanners: An In Vitro Study
    Celeghin, Giordano
    Franceschetti, Giulio
    Mobilio, Nicola
    Fasiol, Alberto
    Catapano, Santo
    Corsalini, Massimo
    Grande, Francesco
    HEALTHCARE, 2021, 9 (03)
  • [47] Accuracy of four intraoral scanners in oral implantology: a comparative in vitro study
    Imburgia, Mario
    Logozzo, Silvia
    Hauschild, Uli
    Veronesi, Giovanni
    Mangano, Carlo
    Mangano, Francesco Guido
    BMC ORAL HEALTH, 2017, 17
  • [48] Accuracy of four intraoral scanners in oral implantology: a comparative in vitro study
    Mario Imburgia
    Silvia Logozzo
    Uli Hauschild
    Giovanni Veronesi
    Carlo Mangano
    Francesco Guido Mangano
    BMC Oral Health, 17
  • [49] Comparative Analysis of Four Different Intraoral Scanners: An In Vitro Study
    Ciocan, Lucian Toma
    Vasilescu, Vlad Gabriel
    Rauta, Sabina-Ana
    Pantea, Mihaela
    Pituru, Silviu-Mirel
    Imre, Marina
    DIAGNOSTICS, 2024, 14 (13)
  • [50] Comparison of digital intraoral scanners and alginate impressions: Time and patient satisfaction
    Burzynski, Jennifer A.
    Firestone, Allen R.
    Beck, F. Michael
    Fields, Henry W., Jr.
    Deguchi, Toru
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2018, 153 (04) : 534 - 541