Inter-observer variation of target volume delineation for CT-guided cervical cancer brachytherapy

被引:3
|
作者
Elmali, Aysenur [1 ]
Biltekin, Fatih [1 ]
Sari, Sezin Yuce [1 ]
Gultekin, Melis [1 ]
Yuce, Deniz [2 ]
Yildiz, Ferah [1 ]
机构
[1] Hacettepe Univ, Dept Radiat Oncol, Fac Med, Ankara, Turkiye
[2] Hacettepe Univ, Dept Prevent Oncol, Fac Med, Ankara, Turkiye
关键词
brachytherapy; cervical cancer; target volume delineation; inter-observer variability; CONFORMAL RADIOTHERAPY; ADAPTIVE BRACHYTHERAPY; COMPUTED-TOMOGRAPHY; LUNG-CANCER; CONTOURING VARIATION; DOSIMETRIC IMPACT; MRI; CARCINOMA; VARIABILITY; GUIDELINES;
D O I
10.5114/jcb.2023.131242
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Delineation is a critical and challenging step in radiotherapy planning. Differences in delineation among observers are common, despite the presence of contouring guidelines. This study aimed to identify the inter-observer variability in the target volume delineation of computed tomography (CT)-guided brachytherapy for cervical cancer. Material and methods: Four radiation oncologists (ROs) with different expertise levels delineated high-risk (HR) and intermediate-risk (IR) clinical target volume (CTV) according to GYN GEC-ESTRO recommendations, in a blinded manner on every CT set of ten locally advanced cervical cancer cases. The most experienced RO's contours were determined as the index and used for comparison. Dice similarity coefficient (DSC) and pairwise Hausdorff distance (HD) metrics were applied to compare the overlap and gross deviations of all contours. Results: Median DSC for HR-CTV and IR-CTV were 0.73 and 0.76, respectively, and a good concordance was achieved for both in majority of contours. While there was no difference in DSC measurements for HR-CTV among the three ROs, RO-3 provided improved DSC values for IR-CTV (p = 0.01). Median HD95 was 5.02 mm and 6.83 mm, and median HDave was 1.69 mm and 2.21 mm for HR-CTV and IR-CTV, respectively. There was no significant difference among ROs in HR-CTV for HD95 or HDave; however, IR-CTV value was significantly improved according to RO-3 (p = 0.01). Case-by-case HD analysis showed no significant inter-observer variations, except for two cases. Conclusions: The inter-observer agreement is generally high for target volumes in CT-guided brachytherapy for cervical cancer. The agreement is lower for IR-CTV than HR-CTV. The individual characteristics of each case and different expertise levels of the ROs may have caused the differences. Despite the good concordance for delineation, dosimetric consequences can still be clinically significant.
引用
收藏
页码:253 / 260
页数:8
相关论文
共 50 条
  • [1] Inter-observer variation in delineation of bladder and rectum contours for brachytherapy of cervical cancer
    Saarnak, AE
    Boersma, M
    van Bunningen, BNFM
    Wolterink, R
    Steggerda, MJ
    RADIOTHERAPY AND ONCOLOGY, 2000, 56 (01) : 37 - 42
  • [2] Evaluating inter-observer variation in oesophageal target volume delineation
    Nicholas, O.
    Lewis, G.
    Thomas, B.
    Smyth, M.
    Spezi, E.
    Gwynne, S. H.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S229 - S230
  • [3] Inter-observer variation in gross tumour volume delineation of oesophageal cancer on MR, CT and PET/CT
    Secerov-Ermenc, Ajra
    Peterlin, Primoz
    Anderluh, Franc
    But-Hadzic, Jasna
    Jeromen-Peressutti, Ana
    Velenik, Vaneja
    Segedin, Barbara
    RADIOLOGY AND ONCOLOGY, 2024, 58 (04) : 580 - 587
  • [4] Inter-observer variability of clinical target volume delineation for bladder cancer using CT and cone beam CT
    Foroudi, F.
    Haworth, A.
    Pangehel, A.
    Wong, J.
    Roxby, P.
    Duchesne, G.
    Williams, S.
    Tai, K. H.
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2009, 53 (01): : 100 - 106
  • [5] Inter-observer variation in GTV delineation of esophageal cancer on MR, CT and PET CT
    Ermenc, A. Secerov
    Peterlin, P.
    Anderluh, F.
    Peressutti, A. Jeromen
    Hadzic, J. But
    Velenik, V.
    Segedin, B.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1096 - S1097
  • [6] Inter-observer and intra-observer reliability for lung cancer target volume delineation in the 4D-CT era
    Rodrigues, George
    Louie, Alexander
    Olsthoorn, Jason
    Palma, David
    Yu, Edward
    Yaremko, Brian
    Ahmad, Belal
    Aivas, Inge
    Gaede, Stewart
    JOURNAL OF THORACIC ONCOLOGY, 2009, 4 (09) : S532 - S533
  • [7] Inter-observer and intra-observer reliability for lung cancer target volume delineation in the 4D-CT era
    Louie, Alexander V.
    Rodrigues, George
    Olsthoorn, Jason
    Palma, David
    Yu, Edward
    Yaremko, Brian
    Ahmad, Bela
    Aivas, Inge
    Gaede, Stewart
    RADIOTHERAPY AND ONCOLOGY, 2010, 95 (02) : 166 - 171
  • [8] INTER-OBSERVER AND INTRA-OBSERVER TARGET VOLUME DELINEATION VARIABILITY IN OROPHARYNGEAL CANCER PATIENTS WITH SIGNIFICANT DENTAL ARTIFACT ON CT
    Louie, A.
    Venkatesan, V.
    Wiebe, E.
    Read, N.
    Hammond, A.
    Rodrigues, G.
    Tay, K. Y.
    Ho, D.
    Gulka, I.
    Fung, K.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S53 - S54
  • [9] Inter-observer and Intra-observer Reliability for Lung Cancer Target Volume Delineation in the 4D-CT Era
    Louie, A. V.
    Rodrigues, G.
    Olsthoorn, J.
    Palma, D.
    Yu, E.
    Yaremko, B.
    Ahmad, B.
    Aivas, I.
    Gaede, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S472 - S473
  • [10] Inter-observer and lntra-observer Target Volume Delineation Variability in Oropharyngeal Cancer Patients with Significant Dental Artifact on CT
    Venkatesan, V.
    Louie, A. V.
    Wiebe, E.
    Read, N.
    Hammond, A.
    Rodrigues, G.
    Tey, K.
    Ho, D.
    Gulka, I.
    Fung, K.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S458 - S458