Inter-observer variation of target volume delineation for CT-guided cervical cancer brachytherapy

被引:3
|
作者
Elmali, Aysenur [1 ]
Biltekin, Fatih [1 ]
Sari, Sezin Yuce [1 ]
Gultekin, Melis [1 ]
Yuce, Deniz [2 ]
Yildiz, Ferah [1 ]
机构
[1] Hacettepe Univ, Dept Radiat Oncol, Fac Med, Ankara, Turkiye
[2] Hacettepe Univ, Dept Prevent Oncol, Fac Med, Ankara, Turkiye
关键词
brachytherapy; cervical cancer; target volume delineation; inter-observer variability; CONFORMAL RADIOTHERAPY; ADAPTIVE BRACHYTHERAPY; COMPUTED-TOMOGRAPHY; LUNG-CANCER; CONTOURING VARIATION; DOSIMETRIC IMPACT; MRI; CARCINOMA; VARIABILITY; GUIDELINES;
D O I
10.5114/jcb.2023.131242
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Delineation is a critical and challenging step in radiotherapy planning. Differences in delineation among observers are common, despite the presence of contouring guidelines. This study aimed to identify the inter-observer variability in the target volume delineation of computed tomography (CT)-guided brachytherapy for cervical cancer. Material and methods: Four radiation oncologists (ROs) with different expertise levels delineated high-risk (HR) and intermediate-risk (IR) clinical target volume (CTV) according to GYN GEC-ESTRO recommendations, in a blinded manner on every CT set of ten locally advanced cervical cancer cases. The most experienced RO's contours were determined as the index and used for comparison. Dice similarity coefficient (DSC) and pairwise Hausdorff distance (HD) metrics were applied to compare the overlap and gross deviations of all contours. Results: Median DSC for HR-CTV and IR-CTV were 0.73 and 0.76, respectively, and a good concordance was achieved for both in majority of contours. While there was no difference in DSC measurements for HR-CTV among the three ROs, RO-3 provided improved DSC values for IR-CTV (p = 0.01). Median HD95 was 5.02 mm and 6.83 mm, and median HDave was 1.69 mm and 2.21 mm for HR-CTV and IR-CTV, respectively. There was no significant difference among ROs in HR-CTV for HD95 or HDave; however, IR-CTV value was significantly improved according to RO-3 (p = 0.01). Case-by-case HD analysis showed no significant inter-observer variations, except for two cases. Conclusions: The inter-observer agreement is generally high for target volumes in CT-guided brachytherapy for cervical cancer. The agreement is lower for IR-CTV than HR-CTV. The individual characteristics of each case and different expertise levels of the ROs may have caused the differences. Despite the good concordance for delineation, dosimetric consequences can still be clinically significant.
引用
收藏
页码:253 / 260
页数:8
相关论文
共 50 条
  • [31] CT-GUIDED INTRACAVITARY BRACHYTHERAPY FOR THE TREATMENT OF CERVICAL CANCER: A PROSPECTIVE STUDY
    Du, X.
    Sheng, X.
    Wang, C.
    Lu, C.
    INTERNATIONAL JOURNAL OF GYNECOLOGICAL CANCER, 2013, 23 (08)
  • [32] Inter-observer variability in target delineation for brain metastases in stereotactic radiotherapy
    Di Biase, S.
    Patani, F.
    Fasciolo, D.
    Rosa, C.
    Di Carlo, C.
    Allajbej, A.
    Gasparini, L.
    Delli Pizzi, A.
    Trignani, M.
    Caravatta, L.
    Genovesi, D.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S682 - S682
  • [33] Evaluation of inter-observer variations in target delineation - A dose based approach
    Kristensen
    Nilsson, K.
    Knoos, T.
    Nilsson, P.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S883 - S884
  • [34] Inter-observer variation in GTV delineation of bone metastases: a multicenter study
    Gerlich, A. S.
    Van der Velden, J. M.
    Kotte, A. N. T. J.
    Tseng, C. L.
    Fanetti, G.
    Eppinga, W. S. C.
    Kasperts, N.
    Intven, M. P. W.
    Pameijer, F. A.
    Philippens, M. E. P.
    Verkooijen, H. M.
    Seravalli, E.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S392 - S393
  • [35] Inter-observer delineation variation and dose to hippocampus in hippocampus avoidance PCI
    Bartel, F.
    Van Herk, M.
    Vrenken, H.
    Vandaele, F.
    Sunaert, S.
    De Jaeger, K.
    Dollekamp, N.
    Carbaat, C.
    Lamers, E.
    Dieleman, E.
    Lievens, Y.
    De Ruysscher, D.
    Schagen, S.
    De Ruiter, M.
    De Munck, J.
    Belderbos, J.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S384 - S385
  • [36] Reduced inter-observer and intra-observer delineation variation in esophageal cancer radiotherapy by use of fiducial markers
    Machiels, Melanie
    Jin, Peng
    van Hooft, Jeanin E.
    Gurney-Champion, Oliver J.
    Jelvehgaran, Pouya
    Geijsen, Elizabeth D.
    Jeene, Paul M.
    Kolff, M. Willemijn
    Oppedijk, Vera
    Rasch, Coen. R. N.
    van Herk, Marcel B.
    Alderliesten, Tanja
    Hulshof, Maarten C. C. M.
    ACTA ONCOLOGICA, 2019, 58 (06) : 943 - 950
  • [37] Inter-observer variability of clinical target volume delineation in radiotherapy treatment of pancreatic cancer: a multi-institutional contouring experience
    Luciana Caravatta
    Gabriella Macchia
    Gian Carlo Mattiucci
    Aldo Sainato
    Nunzia LV Cernusco
    Giovanna Mantello
    Monica Di Tommaso
    Marianna Trignani
    Antonino De Paoli
    Gianni Boz
    Maria L Friso
    Vincenzo Fusco
    Marta Di Nicola
    Alessio G Morganti
    Domenico Genovesi
    Radiation Oncology, 9
  • [38] Inter-observer variability of clinical target volume delineation in radiotherapy treatment of pancreatic cancer: a multi-institutional contouring experience
    Caravatta, Luciana
    Macchia, Gabriella
    Mattiucci, Gian Carlo
    Sainato, Aldo
    Cernusco, Nunzia L. V.
    Mantello, Giovanna
    Di Tommaso, Monica
    Trignani, Marianna
    De Paoli, Antonino
    Boz, Gianni
    Friso, Maria L.
    Fusco, Vincenzo
    Di Nicola, Marta
    Morganti, Alessio G.
    Genovesi, Domenico
    RADIATION ONCOLOGY, 2014, 9
  • [39] Hybrid TRUS/CT with optical tracking for target delineation in image-guided adaptive brachytherapy for cervical cancer
    Smet, Stephanie
    Nesvacil, Nicole
    Knoth, Johannes
    Sturdza, Alina
    Najjari-Jamal, Dina
    Jelinek, Filip
    Kronreif, Gernot
    Poetter, Richard
    Widder, Joachim
    Kirisits, Christian
    Schmid, Maximilian P.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2020, 196 (11) : 983 - 992
  • [40] Hybrid TRUS/CT with optical tracking for target delineation in image-guided adaptive brachytherapy for cervical cancer
    Stéphanie Smet
    Nicole Nesvacil
    Johannes Knoth
    Alina Sturdza
    Dina Najjari-Jamal
    Filip Jelinek
    Gernot Kronreif
    Richard Pötter
    Joachim Widder
    Christian Kirisits
    Maximilian P. Schmid
    Strahlentherapie und Onkologie, 2020, 196 : 983 - 992