Anterior talofibular ligament footprint dimension measured using three-dimensional magnetic resonance imaging

被引:0
|
作者
Kono, Kenta [1 ]
Yamaguchi, Satoshi [1 ,2 ]
Kimura, Seiji [1 ]
Mikami, Yukio [1 ]
Kitsukawa, Kaoru [3 ]
Matsumoto, Koji [4 ]
Edama, Mutsuaki [5 ]
Shiko, Yuki [6 ]
Horii, Manato [1 ]
Sasho, Takahisa [1 ,7 ]
Ohtori, Seiji [1 ]
机构
[1] Chiba Univ, Grad Sch Med & Pharmaceut Sci, Dept Orthopaed Surg, 1-8-1 Inohana,Chuo Ku, Chiba, Chiba 2608670, Japan
[2] Chiba Univ, Grad Sch Global & Transdisciplinary Studies, Chiba, Japan
[3] Chiba Univ, Grad Sch Med & Pharmaceut Sci, Dept Diagnost Radiol & Radiat Oncol, Chiba, Japan
[4] Chiba Univ Hosp, Dept Radiol, Chiba, Japan
[5] Niigata Univ Hlth & Welf, Inst Human Movement & Med Sci, Niigata, Japan
[6] Chiba Univ Hosp, Clin Res Ctr, Biostat Sect, Chiba, Japan
[7] Chiba Univ, Ctr Prevent Med Sci, Chiba, Japan
关键词
Ankle; Anatomy; Anterior talofibular ligament; Magnetic resonance imaging; INSERTION SITE; ANKLE; ANATOMY; COMPLEX;
D O I
10.1007/s00256-024-04778-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective Knowledge of footprint anatomy is essential for ankle anterior talofibular ligament repair and reconstruction. We aimed to determine the intra- and inter-rater measurement reliability of the anterior talofibular ligament footprint dimension using three-dimensional MRI. Methods MRI images of 20 ankles with intact ligaments, including 11 with a single bundle and nine with double-bundle ligaments, were analyzed. Imaging was performed using a 3.0-Tesla MRI. Isotropic three-dimensional proton density-weighted images with a voxel size of 0.6 mm were obtained. The fibular and talar footprints were manually segmented using image processing software to create three-dimensional ligament footprints. The lengths, widths, and areas of each sample were measured. A certified orthopedic surgeon and a senior orthopedic fellow performed the measurements twice at 6-week intervals. The intra- and inter-rater differences in the measurements were calculated. Results The length, width, and area of the single-bundle fibular footprint were 8.7 mm, 5.4 mm, and 37.4 mm2, respectively. Those of the talar footprint were 8.4 mm, 4.3 mm, and 30.1 mm2, respectively. The inferior bundle of the double-bundle ligament was significantly smaller than the single and superior bundles (p < 0.001). No differences were observed between intra-rater measurements by either rater, with maximum differences of 0.7 mm, 0.5, and 1.7 mm2, in length, width, and area, respectively. The maximum inter-rater measurement differences were 1.9 mm, 0.5, and 2.4 mm2, respectively. Conclusion Measurements of the anterior talofibular ligament dimensions using three-dimensional MRI were sufficiently reliable. This measurement method provides in vivo quantitative data on ligament footprint anatomy.
引用
收藏
页码:937 / 945
页数:9
相关论文
共 50 条
  • [21] Reliability and Validity of Magnetic Resonance Imaging for the Evaluation of the Anterior Talofibular Ligament in Patients Undergoing Ankle Arthroscopy
    Kim, Yong Sang
    Kim, Yong Beom
    Kim, Tae Gyun
    Lee, Seung Woo
    Park, Sung Ho
    Lee, Ho Jin
    Choi, Yun Jin
    Koh, Yong Gon
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2015, 31 (08): : 1540 - 1547
  • [22] Three-Dimensional In Vivo Patellofemoral Kinematics and Contact Area of Anterior Cruciate Ligament-Deficient and -Reconstructed Subjects Using Magnetic Resonance Imaging
    Shin, Choongsoo S.
    Carpenter, R. Dana
    Majumdar, Sharmila
    Ma, C. Benjamin
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2009, 25 (11): : 1214 - 1223
  • [23] Three-dimensional magnetic resonance imaging for groundwater
    Legchenko, A.
    Descloitres, M.
    Vincent, C.
    Guyard, H.
    Garambois, S.
    Chalikakis, K.
    Ezersky, M.
    NEW JOURNAL OF PHYSICS, 2011, 13
  • [24] Three-Dimensional Magnetic Resonance Imaging for Guiding Tibial and Femoral Tunnel Position in Anterior Cruciate Ligament Reconstruction: A Cadaveric Study
    Marwan, Yousef
    Bottcher, Jens
    Laverdiere, Carl
    Jaffer, Rehana
    Burman, Mark
    Boily, Mathieu
    Martineau, Paul A.
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2020, 8 (03)
  • [25] Three-dimensional localization of impacted teeth using magnetic resonance imaging
    O. Tymofiyeva
    K. Rottner
    P. M. Jakob
    E.-J. Richter
    P. Proff
    Clinical Oral Investigations, 2010, 14 : 169 - 176
  • [26] Three-Dimensional Visualization Using Magnetic Resonance Imaging for Episcleral Brachytherapy
    Rodriguez, V.
    Bertelsman, C.
    DeWees, T.
    Hu, Y.
    Rao, P. Kumar
    Garcia-Ramirez, J.
    Grigsby, P.
    Esthappan, J.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [27] Three-dimensional localization of impacted teeth using magnetic resonance imaging
    Tymofiyeva, O.
    Rottner, K.
    Jakob, P. M.
    Richter, E. -J.
    Proff, P.
    CLINICAL ORAL INVESTIGATIONS, 2010, 14 (02) : 169 - 176
  • [28] A proposed scheme for comprehensive characterization of the measured geometric distortion in magnetic resonance imaging using a three-dimensional phantom
    Wang, DM
    Doddrell, DM
    MEDICAL PHYSICS, 2004, 31 (08) : 2212 - 2218
  • [29] Three-dimensional geometry of the human biceps femoris long head measured in vivo using magnetic resonance imaging
    Schache, Anthony G.
    Ackland, David C.
    Fok, Laurence
    Koulouris, George
    Pandy, Marcus G.
    CLINICAL BIOMECHANICS, 2013, 28 (03) : 278 - 284
  • [30] Evaluation of ossification of the posterior longitudinal ligament by three-dimensional computed tomography and magnetic resonance imaging
    Kawaguchi, Yoshiharu
    Urushisaki, Aya
    Seki, Shoji
    Hori, Takeshi
    Asanuma, Yumiko
    Kimura, Tomoatsu
    SPINE JOURNAL, 2011, 11 (10): : 927 - 932