Anterior talofibular ligament footprint dimension measured using three-dimensional magnetic resonance imaging

被引:0
|
作者
Kono, Kenta [1 ]
Yamaguchi, Satoshi [1 ,2 ]
Kimura, Seiji [1 ]
Mikami, Yukio [1 ]
Kitsukawa, Kaoru [3 ]
Matsumoto, Koji [4 ]
Edama, Mutsuaki [5 ]
Shiko, Yuki [6 ]
Horii, Manato [1 ]
Sasho, Takahisa [1 ,7 ]
Ohtori, Seiji [1 ]
机构
[1] Chiba Univ, Grad Sch Med & Pharmaceut Sci, Dept Orthopaed Surg, 1-8-1 Inohana,Chuo Ku, Chiba, Chiba 2608670, Japan
[2] Chiba Univ, Grad Sch Global & Transdisciplinary Studies, Chiba, Japan
[3] Chiba Univ, Grad Sch Med & Pharmaceut Sci, Dept Diagnost Radiol & Radiat Oncol, Chiba, Japan
[4] Chiba Univ Hosp, Dept Radiol, Chiba, Japan
[5] Niigata Univ Hlth & Welf, Inst Human Movement & Med Sci, Niigata, Japan
[6] Chiba Univ Hosp, Clin Res Ctr, Biostat Sect, Chiba, Japan
[7] Chiba Univ, Ctr Prevent Med Sci, Chiba, Japan
关键词
Ankle; Anatomy; Anterior talofibular ligament; Magnetic resonance imaging; INSERTION SITE; ANKLE; ANATOMY; COMPLEX;
D O I
10.1007/s00256-024-04778-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective Knowledge of footprint anatomy is essential for ankle anterior talofibular ligament repair and reconstruction. We aimed to determine the intra- and inter-rater measurement reliability of the anterior talofibular ligament footprint dimension using three-dimensional MRI. Methods MRI images of 20 ankles with intact ligaments, including 11 with a single bundle and nine with double-bundle ligaments, were analyzed. Imaging was performed using a 3.0-Tesla MRI. Isotropic three-dimensional proton density-weighted images with a voxel size of 0.6 mm were obtained. The fibular and talar footprints were manually segmented using image processing software to create three-dimensional ligament footprints. The lengths, widths, and areas of each sample were measured. A certified orthopedic surgeon and a senior orthopedic fellow performed the measurements twice at 6-week intervals. The intra- and inter-rater differences in the measurements were calculated. Results The length, width, and area of the single-bundle fibular footprint were 8.7 mm, 5.4 mm, and 37.4 mm2, respectively. Those of the talar footprint were 8.4 mm, 4.3 mm, and 30.1 mm2, respectively. The inferior bundle of the double-bundle ligament was significantly smaller than the single and superior bundles (p < 0.001). No differences were observed between intra-rater measurements by either rater, with maximum differences of 0.7 mm, 0.5, and 1.7 mm2, in length, width, and area, respectively. The maximum inter-rater measurement differences were 1.9 mm, 0.5, and 2.4 mm2, respectively. Conclusion Measurements of the anterior talofibular ligament dimensions using three-dimensional MRI were sufficiently reliable. This measurement method provides in vivo quantitative data on ligament footprint anatomy.
引用
收藏
页码:937 / 945
页数:9
相关论文
共 50 条
  • [41] Quantification of bone marrow water and lipid composition in anterior cruciate ligament-injured and osteoarthritic knees using three-dimensional magnetic resonance spectroscopic imaging
    Tufts, Lauren S.
    Shet, Keerthi
    Liang, Fei
    Majumdar, Sharmila
    Li, Xiaojuan
    MAGNETIC RESONANCE IMAGING, 2016, 34 (05) : 632 - 637
  • [42] Magnetic resonance imaging verification of anterior capsular impingement in the hip joint: A three-dimensional analysis
    Hyakutake, Subaru
    Tateuchi, Hiroshige
    Yagi, Masahide
    Itsuda, Hikari
    Wang, Zimin
    Nakai, Ryusuke
    Ichihashi, Noriaki
    CLINICAL BIOMECHANICS, 2024, 120
  • [43] The signal intensity of preoperative magnetic resonance imaging has predictive value for determining the arthroscopic reparability of the anterior talofibular ligament
    Ahn, Jungtae
    Choi, Jung Gyu
    Jeong, Bi O.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2021, 29 (05) : 1535 - 1543
  • [44] The signal intensity of preoperative magnetic resonance imaging has predictive value for determining the arthroscopic reparability of the anterior talofibular ligament
    Jungtae Ahn
    Jung Gyu Choi
    Bi O Jeong
    Knee Surgery, Sports Traumatology, Arthroscopy, 2021, 29 : 1535 - 1543
  • [45] Evaluation of lung volumetry using dynamic three-dimensional magnetic resonance imaging
    Plathow, C
    Schoebinger, M
    Fink, C
    Ley, S
    Puderbach, M
    Eichinger, M
    Bock, M
    Meinzer, HP
    Kauczor, HU
    INVESTIGATIVE RADIOLOGY, 2005, 40 (03) : 173 - 179
  • [46] An improved three-dimensional concentration measurement technique using magnetic resonance imaging
    Banko, Andrew J.
    Benson, Michael J.
    Gunady, Ian E.
    Elkins, Christopher J.
    Eaton, John K.
    EXPERIMENTS IN FLUIDS, 2020, 61 (02)
  • [47] Three-dimensional reconstruction of fetal abnormalities using ultrasonography and magnetic resonance imaging
    Werner, Heron
    Marcondes, Maene
    Daltro, Pedro
    Fazecas, Tatiana
    Ribeiro, Bianca Guedes
    Nogueira, Renata
    Araujo Junior, Edward
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2019, 32 (20): : 3502 - 3508
  • [48] An improved three-dimensional concentration measurement technique using magnetic resonance imaging
    Andrew J. Banko
    Michael J. Benson
    Ian E. Gunady
    Christopher J. Elkins
    John K. Eaton
    Experiments in Fluids, 2020, 61
  • [49] Quantitation of articular cartilage using magnetic resonance imaging and three-dimensional reconstruction
    Marshall, KW
    Mikulis, DJ
    Guthrie, BM
    JOURNAL OF ORTHOPAEDIC RESEARCH, 1995, 13 (06) : 814 - 823
  • [50] Oblique MR imaging of the anterior cruciate ligament based on three-dimensional orientation
    Breitenseher, Martin J.
    Mayerhoefer, Marius E.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (03) : 794 - 798