INTEGRATION OF THERMAL ENERGY STORAGE MATERIALS IN HEAT PIPE EVACUATED TUBE SOLAR COLLECTOR SYSTEMS FOR ENHANCED SOLAR THERMAL PERFORMANCE

被引:0
|
作者
Hachim, Dhafer Manea [1 ]
Eidan, Adel A. [1 ]
Alshukri, Mohammed J. [2 ,3 ]
Al-Fahham, Mohamed [1 ]
Alsahlani, Assaad [1 ]
Al-Manea, Ahmed [4 ]
Al-Rbaihat, Raed [5 ]
Alahmer, Ali [6 ]
机构
[1] Al Furat Al Awsat Tech Univ, Engn Tech Coll, Al Najaf 31001, Iraq
[2] Kufa Univ, Fac Engn, Dept Mech Engn, Najaf 54002, Iraq
[3] Islamic Univ, Coll Tech Engn, Refrigerat & Air Conditioning Tech Engn Dept, Najaf, Iraq
[4] Al Furat Al Awsat Tech Univ, Dept Mech Engn, Najaf, Iraq
[5] Tafila Tech Univ, Fac Engn, Dept Mech Engn, POB 179, Tafila 66110, Jordan
[6] Tuskegee Univ, Dept Mech Engn, Tuskegee, AL 36088 USA
来源
COMPUTATIONAL THERMAL SCIENCES | 2024年 / 16卷 / 06期
关键词
solar water heater; evacuated tube; heat pipe solar collector; thermal energy storage; phase change material; numerical; PHASE-CHANGE MATERIALS; NUMERICAL-ANALYSIS; BUILDINGS; PCM;
D O I
10.1615/ComputThermalScien.2024053130
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study investigates integrating thermal energy storage materials (TESM) with a heat pipe evacuated tube solar collector (HP-ETSC) in a water tank. Three TESMs (paraffin wax, RT27, and RT35) were examined numerically using COMSOL software, and experiments were conducted. Different design parameters were discussed, including water tank thickness, TESM tank thickness, TESM types, flow rate, and environmental conditions. The integration of TESM into the HP-ETSC allows the evaluation of various thermal performances, including average water tank temperature, hot water outlet temperature, and duration of hot water availability after sunset. The findings indicate a maximum temperature difference of approximately 37 degrees C at 13:00 on March 19 without TESM. However, with RT35, the temperature difference is around 34.27 degrees C, and with RT27, it is approximately 33.4 degrees C. Additionally, the temperature difference is approximately 2 degrees C higher when TESM is not utilized during the three months at sunset. These results demonstrate improved thermal performance compared to a similar system without TESM. Thermal energy transmission from TESM to water is relatively low, resulting in slightly higher outlet water temperature at night. During cloudy periods, RT27 and RT35 TESM types maintain their melting temperature from 11:00 to 20:00. A water storage tank thickness of 35 mm yields the highest temperature difference with RT27 and RT35 TESM. Increasing TESM thickness allows for more mass and latent heat storage, leading to up to 3.5 hours of heat release. On a mostly sunny day, such as January 9, the HP-ETSC stops heat release around 16:30 without TESM, while the TESM plates prolong the discharge duration by three hours.
引用
收藏
页码:59 / 85
页数:28
相关论文
共 50 条
  • [1] Thermal Performance of Evacuated Tube Heat Pipe Solar Collector
    Putra, Nandy
    Kristian, M. R.
    David, R.
    Haliansyah, K.
    Ariantara, Bambang
    PROCEEDINGS OF THE 3RD AUN/SEED-NET REGIONAL CONFERENCE ON ENERGY ENGINEERING AND THE 7TH INTERNATIONAL CONFERENCE ON THERMOFLUIDS (RCENE/THERMOFLUID 2015), 2016, 1737
  • [2] Thermal performance of U-pipe evacuated tube solar collector with latent heat thermal energy storage
    Liu Y.
    Li T.
    Li Y.
    Chen Y.
    Wang D.
    Liu J.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2021, 42 (07): : 244 - 250
  • [3] CFD modeling of a thermal energy storage based heat pipe evacuated tube solar collector
    Pawar, Vivek R.
    Sobhansarbandi, Sarvenaz
    JOURNAL OF ENERGY STORAGE, 2020, 30
  • [4] Solar dryer using evacuated tube solar thermal collector with thermal storage
    Devi, T. H. Bidyalakshmi
    Singh, S. K.
    Mani, Indra
    Kumar, S.
    Yadav, V
    Singh, Y.
    Sangwan, Sunil K.
    INDIAN JOURNAL OF AGRICULTURAL SCIENCES, 2023, 93 (02): : 233 - 236
  • [5] Optical and thermal performance analysis of a compact solar collector with heat-pipe evacuated tube
    Yang, Moucun
    Zhi, Liming
    Diao, Kelong
    Zhu, Yuezhao
    Taylor, Robert A.
    SOLAR ENERGY, 2023, 258 : 118 - 129
  • [6] Effect of twisted tape inserts on thermal performance of heat pipe evacuated-tube solar thermal collector
    Joo, Hong-Jin
    Kwak, Hee-Youl
    Kong, Minsuk
    ENERGY, 2022, 254
  • [7] Energy and exergy assessment of integrating reflectors on thermal energy storage of evacuated tube solar collector-heat pipe system
    Abo-Elfadl, Saleh
    Hassan, Hamdy
    El-Dosoky, M. F.
    SOLAR ENERGY, 2020, 209 : 470 - 484
  • [8] Thermal performance investigation of energy storage based U-pipe evacuated tube solar collector: An experimental study
    O'Neil, Tyler J.E.
    Sobhansarbandi, Sarvenaz
    Sustainable Energy Technologies and Assessments, 2022, 52
  • [9] Thermal performance investigation of energy storage based U-pipe evacuated tube solar collector: An experimental study
    O'Neil, Tyler J. E.
    Sobhansarbandi, Sarvenaz
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2022, 52
  • [10] Experimental studies of thermal performance of an evacuated tube heat pipe solar collector in Polish climatic conditions
    Siuta-Olcha, Alicja
    Cholewa, Tomasz
    Dopieralska-Howoruszko, Kinga
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2021, 28 (12) : 14319 - 14328