A performance comparison study between two HPGe lung counters with different detector configurations

被引:0
|
作者
Naito, Masayuki [1 ]
Tamakuma, Yuki [2 ]
Mihei, Yuma [1 ]
Yajima, Kazuaki [1 ]
Tani, Kotaro [1 ,3 ]
Kim, Eunjoo [1 ]
Kowatari, Munehiko [1 ]
Kurihara, Osamu [1 ]
机构
[1] Natl Inst Quantum Sci & Technol, 4-9-1 Anagawa, Chiba 2638555, Japan
[2] Nagasaki Univ, 1-12-4 Sakamoto, Nagasaki 8528523, Japan
[3] Tokyo Metropolitan Univ, 7-2-10 Higashi Ogu, Tokyo 1168551, Japan
关键词
SYSTEM;
D O I
10.1093/rpd/ncae183
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study compares the performance of old and new lung counters in the National Institutes for Quantum Sciences and Technology of Japan. The total sensitive area of the detector crystals for the new lung counter is similar to 15% smaller than that for the old lung counter. Minimum detectable activities (MDAs) for Am-241 and Pu-239 were evaluated through experiments using a Lawrence Livermore National Laboratory torso phantom. Despite differences in detector configuration, the MDAs were found to be comparable between the two lung counters. For a chest wall thickness of 2.1 cm and a counting time of 30 min, the MDAs of Am-241 and Pu-239 were 5.7 and 2300 Bq for the old lung counter, and 5.5 and 2600 Bq for the new lung counter, respectively. Experimental results for the relative sensitivities between left-side and right-side detectors suggested that the new lung counter offered better measurement geometry.
引用
收藏
页码:1486 / 1491
页数:6
相关论文
共 50 条
  • [1] Performance comparison between two different injector configurations in a hybrid rocket
    Carmicino, C.
    Sorge, A. Russo
    AEROSPACE SCIENCE AND TECHNOLOGY, 2007, 11 (01) : 61 - 67
  • [2] Comparison of background in underground HPGe-detectors in different lead shield configurations
    Hult, Mikael
    Lutter, Guillaume
    Yuksel, Ayhan
    Marissens, Gerd
    Misiaszek, Marcin
    Rosengard, Ulf
    APPLIED RADIATION AND ISOTOPES, 2013, 81 : 103 - 108
  • [3] Comparison Between Two Different Rotary Configurations of an Elastocaloric Cooling Device
    Cirillo, Luca
    Greco, Adriana
    Masselli, Claudia
    SHAPE MEMORY AND SUPERELASTICITY, 2024, : 422 - 434
  • [4] The comparison of PHE performance for different configurations
    Wu, CC
    Yang, BC
    Shyu, RJ
    COMPACT HEAT EXCHANGERS FOR THE PROCESS INDUSTRIES, 1997, : 247 - 252
  • [5] Performance comparison of electrorheological valves with two different geometric configurations: cylinder and plate
    Han, Y-M
    Sung, K-G
    Sohn, J. W.
    Choi, S-B
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2009, 223 (03) : 573 - 581
  • [6] Comparison of the performance of two different DOAS configurations involving conventional and renewable energies
    Martinez, Pedro J.
    Martinez, Pedro
    Soto, Victor M.
    Kaiser, Antonio S.
    SOLAR ENERGY, 2018, 169 : 284 - 296
  • [7] Numerical and experimental comparison between two different blade configurations of a wind generator
    Alaimo, Andrea
    Lo Iacono, Francesco
    Navarra, Giacomo
    Pipitone, Giovanni
    COMPOSITE STRUCTURES, 2016, 136 : 526 - 537
  • [8] Comparison between different data buses configurations
    Lopez, A
    Deschacht, D
    VLSI 2004: IEEE COMPUTER SOCIETY ANNUAL SYMPOSIUM ON VLSI, PROCEEDINGS, 2004, : 69 - 74
  • [9] A COMPARISON OF DIFFERENT MESFET CONFIGURATIONS IN TERMS OF MICROWAVE PERFORMANCE
    TRAUT, FA
    VANDERMERWE, DG
    SNYMAN, LW
    SOUTH AFRICAN JOURNAL OF SCIENCE, 1991, 87 (3-4) : 113 - 116
  • [10] Thermal performance comparison of different sun tracking configurations☆
    Achkari, O.
    El Fadar, A.
    EUROPEAN PHYSICAL JOURNAL-APPLIED PHYSICS, 2020, 88 (02):