A performance comparison study between two HPGe lung counters with different detector configurations

被引:0
|
作者
Naito, Masayuki [1 ]
Tamakuma, Yuki [2 ]
Mihei, Yuma [1 ]
Yajima, Kazuaki [1 ]
Tani, Kotaro [1 ,3 ]
Kim, Eunjoo [1 ]
Kowatari, Munehiko [1 ]
Kurihara, Osamu [1 ]
机构
[1] Natl Inst Quantum Sci & Technol, 4-9-1 Anagawa, Chiba 2638555, Japan
[2] Nagasaki Univ, 1-12-4 Sakamoto, Nagasaki 8528523, Japan
[3] Tokyo Metropolitan Univ, 7-2-10 Higashi Ogu, Tokyo 1168551, Japan
关键词
SYSTEM;
D O I
10.1093/rpd/ncae183
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study compares the performance of old and new lung counters in the National Institutes for Quantum Sciences and Technology of Japan. The total sensitive area of the detector crystals for the new lung counter is similar to 15% smaller than that for the old lung counter. Minimum detectable activities (MDAs) for Am-241 and Pu-239 were evaluated through experiments using a Lawrence Livermore National Laboratory torso phantom. Despite differences in detector configuration, the MDAs were found to be comparable between the two lung counters. For a chest wall thickness of 2.1 cm and a counting time of 30 min, the MDAs of Am-241 and Pu-239 were 5.7 and 2300 Bq for the old lung counter, and 5.5 and 2600 Bq for the new lung counter, respectively. Experimental results for the relative sensitivities between left-side and right-side detectors suggested that the new lung counter offered better measurement geometry.
引用
收藏
页码:1486 / 1491
页数:6
相关论文
共 50 条
  • [21] Exergy analysis of hypersonic propulsion systems: Performance comparison of two different scramjet configurations at cruise conditions
    Amati, V.
    Bruno, C.
    Simone, D.
    Sciubba, E.
    ENERGY, 2008, 33 (02) : 116 - 129
  • [22] Comparison between HPGe and CdZnTe detector for the correlation between calculated radioactivity and measured dose using an activated concrete sample
    Chaudhury, Sanhita
    Agarwal, Chhavi
    Goswami, A.
    Gathibandhe, Manohar
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2012, 294 (03) : 461 - 464
  • [23] Comparison between two different luting systems: a microleakage study
    Re, D
    Gagliani, M
    Cadamuro, A
    JOURNAL OF DENTAL RESEARCH, 2000, 79 : 354 - 354
  • [24] Comparison of different joint configurations between two parallel SS-laminated BSCCO/Ag tapes
    Kar, S.
    Kumar, R.
    Konduru, P.
    Datta, T. S.
    PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2010, 470 (13-14): : 523 - 527
  • [25] Comparison of two moving target detector's performance
    Li, H
    Chen, YH
    Liu, H
    ICSP '96 - 1996 3RD INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING, PROCEEDINGS, VOLS I AND II, 1996, : 867 - 870
  • [26] Theoretical comparison between different configurations of radial and conventional bogies
    Garcia, JF
    Olaizola, X
    Martin, LM
    Gimenez, JG
    VEHICLE SYSTEM DYNAMICS, 2000, 33 (04) : 233 - 259
  • [27] Comparison of mechanical performance among different frame configurations of the Ilizarov external fixator: Experimental study
    Sarpel, Y
    Gulsen, M
    Togrul, E
    Capa, M
    Herdem, M
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2005, 58 (03): : 546 - 552
  • [28] Two nanofluid configurations for heat conduction systems: performance comparison
    Bai, Chao
    Wang, Liqiu
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2013, 66 : 632 - 641
  • [29] Performance study of new pixel hybrid photon detector prototypes for the LHCb RICH counters
    Moritz, M
    Rinella, GA
    Allebone, L
    Campbell, M
    Gys, T
    Newby, C
    Pickford, A
    Piedigrossi, D
    Wyllie, K
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 986 - 990
  • [30] Oxygenation performance assessment of an artificial lung in different central anatomic configurations
    Hima, Flutura
    Kalverkamp, Sebastian
    Kashefi, Ali
    Mottaghy, Khosrow
    Zayat, Rachad
    Strudthoff, Lasse
    Spillner, Jan
    Mouzakis, Foivos
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2023, 46 (05): : 295 - 302