Comparison of the performance of two different DOAS configurations involving conventional and renewable energies

被引:7
|
作者
Martinez, Pedro J. [1 ]
Martinez, Pedro [1 ]
Soto, Victor M. [2 ]
Kaiser, Antonio S. [3 ]
机构
[1] Univ Miguel Hernandes, Dept Ingn Mecan & Energia, Avda Univ S-N, Elche 03202, Spain
[2] Univ Politecn Valencia, Dept Termodinam Aplicada, Camino Vera S-N, E-46022 Valencia, Spain
[3] Univ Politecn Cartagena, Dept Ingn Term & Fluidos, Dr Fleming S-N, Cartagena 30202, Spain
关键词
Desiccant wheel; Solar air collector; TRNSYS; Indirect evaporative cooling; EES; AIR HANDLING UNIT; DESICCANT; BUILDINGS; SYSTEM;
D O I
10.1016/j.solener.2018.05.002
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Spanish building regulations have increased the ventilation rates creating humidity control problems. Dedicated outdoor air systems (DOASs) including a desiccant wheel can dry the ventilation air so that the cooling units are relieved of the latent loads carried by the ventilation air and those generated inside the building. The purpose of this study was to compare the performance of two different DOAS configurations in terms of primary energy consumption under different Spanish climates. The DOAS comprising a desiccant wheel and a conventional refrigeration system was called DOAS-A. The DOAS comprising a desiccant wheel regenerated by solar air collectors and an indirect evaporative cooler was called DOAS-B. The performance of both DOASs was simulated with TRNSYS, and the models were validated with data from experimental setups built at the Miguel Hernandez University of Elche (Spain) and at the Technical University of Cartagena (Spain). It was found that the DOAS-B configuration consumed less primary energy than the DOAS-A configuration for commercial use, that is, when the latent load coincides with the supply of solar radiation. These savings reached 68.3% in Seville owing to its high level of solar radiation. It was also found that the net sensible load supplied by the ventilation air to the conditioned space was negative for all climates. This sensible cooling capacity was shown to be greater at lower outdoor dry-bulb temperature and lower latent load.
引用
收藏
页码:284 / 296
页数:13
相关论文
共 50 条
  • [1] Performance comparison between two different injector configurations in a hybrid rocket
    Carmicino, C.
    Sorge, A. Russo
    AEROSPACE SCIENCE AND TECHNOLOGY, 2007, 11 (01) : 61 - 67
  • [2] The comparison of PHE performance for different configurations
    Wu, CC
    Yang, BC
    Shyu, RJ
    COMPACT HEAT EXCHANGERS FOR THE PROCESS INDUSTRIES, 1997, : 247 - 252
  • [3] Performance comparison of electrorheological valves with two different geometric configurations: cylinder and plate
    Han, Y-M
    Sung, K-G
    Sohn, J. W.
    Choi, S-B
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2009, 223 (03) : 573 - 581
  • [4] Theoretical comparison between different configurations of radial and conventional bogies
    Garcia, JF
    Olaizola, X
    Martin, LM
    Gimenez, JG
    VEHICLE SYSTEM DYNAMICS, 2000, 33 (04) : 233 - 259
  • [5] Performance comparison and investigation of two different renewable energy fueled multigeneration systems
    Heidarnejad, Parisa
    Noorpoor, Alireza
    JOURNAL OF THERMAL ENGINEERING, 2021, 7 (05): : 1039 - 1055
  • [6] Performance comparison between a conventional helicopter and compound helicopter configurations
    Ferguson, Kevin
    Thomson, Douglas
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART G-JOURNAL OF AEROSPACE ENGINEERING, 2015, 229 (13) : 2441 - 2456
  • [7] A performance comparison study between two HPGe lung counters with different detector configurations
    Naito, Masayuki
    Tamakuma, Yuki
    Mihei, Yuma
    Yajima, Kazuaki
    Tani, Kotaro
    Kim, Eunjoo
    Kowatari, Munehiko
    Kurihara, Osamu
    RADIATION PROTECTION DOSIMETRY, 2024, 200 (15) : 1486 - 1491
  • [8] A COMPARISON OF DIFFERENT MESFET CONFIGURATIONS IN TERMS OF MICROWAVE PERFORMANCE
    TRAUT, FA
    VANDERMERWE, DG
    SNYMAN, LW
    SOUTH AFRICAN JOURNAL OF SCIENCE, 1991, 87 (3-4) : 113 - 116
  • [9] Thermal performance comparison of different sun tracking configurations☆
    Achkari, O.
    El Fadar, A.
    EUROPEAN PHYSICAL JOURNAL-APPLIED PHYSICS, 2020, 88 (02):
  • [10] COMPARISON OF THE PERFORMANCE OF HYBRID CODERS UNDER DIFFERENT CONFIGURATIONS
    GUNASEKARAN, S
    RAINA, JP
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1983, 397 : 140 - 148