Comparison of the performance of two different DOAS configurations involving conventional and renewable energies

被引:7
|
作者
Martinez, Pedro J. [1 ]
Martinez, Pedro [1 ]
Soto, Victor M. [2 ]
Kaiser, Antonio S. [3 ]
机构
[1] Univ Miguel Hernandes, Dept Ingn Mecan & Energia, Avda Univ S-N, Elche 03202, Spain
[2] Univ Politecn Valencia, Dept Termodinam Aplicada, Camino Vera S-N, E-46022 Valencia, Spain
[3] Univ Politecn Cartagena, Dept Ingn Term & Fluidos, Dr Fleming S-N, Cartagena 30202, Spain
关键词
Desiccant wheel; Solar air collector; TRNSYS; Indirect evaporative cooling; EES; AIR HANDLING UNIT; DESICCANT; BUILDINGS; SYSTEM;
D O I
10.1016/j.solener.2018.05.002
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Spanish building regulations have increased the ventilation rates creating humidity control problems. Dedicated outdoor air systems (DOASs) including a desiccant wheel can dry the ventilation air so that the cooling units are relieved of the latent loads carried by the ventilation air and those generated inside the building. The purpose of this study was to compare the performance of two different DOAS configurations in terms of primary energy consumption under different Spanish climates. The DOAS comprising a desiccant wheel and a conventional refrigeration system was called DOAS-A. The DOAS comprising a desiccant wheel regenerated by solar air collectors and an indirect evaporative cooler was called DOAS-B. The performance of both DOASs was simulated with TRNSYS, and the models were validated with data from experimental setups built at the Miguel Hernandez University of Elche (Spain) and at the Technical University of Cartagena (Spain). It was found that the DOAS-B configuration consumed less primary energy than the DOAS-A configuration for commercial use, that is, when the latent load coincides with the supply of solar radiation. These savings reached 68.3% in Seville owing to its high level of solar radiation. It was also found that the net sensible load supplied by the ventilation air to the conditioned space was negative for all climates. This sensible cooling capacity was shown to be greater at lower outdoor dry-bulb temperature and lower latent load.
引用
收藏
页码:284 / 296
页数:13
相关论文
共 50 条
  • [31] Performance comparison of different MIMO configurations for downlink MC-CDMA systems
    Peng, XM
    Lei, ZD
    Chin, FPS
    2004 9TH IEEE SINGAPORE INTERNATIONAL CONFERENCE ON COMMUNICATION SYSTEMS (ICCS), 2004, : 281 - 285
  • [32] Comparison of Anaerobic Methane Fermentation Performance and Ammonia Resistance with Different Inoculum Configurations
    Yang, Ziyi
    Sun, Hangyu
    Liu, Yang
    Liu, Chao
    Zhang, Ruihong
    Liu, Guangqing
    Wang, Wen
    ENERGY & FUELS, 2019, 33 (09) : 8711 - 8720
  • [33] Performance of Two Different Flight Configurations for Drone-Borne Magnetic Data
    Accomando, Filippo
    Vitale, Andrea
    Bonfante, Antonello
    Buonanno, Maurizio
    Florio, Giovanni
    SENSORS, 2021, 21 (17)
  • [34] Performance comparison between conventional and AFC media at different orientation ratios
    Zhou, JN
    Acharya, BR
    Abarra, EN
    Choe, G
    Gao, J
    Johnson, KE
    IEEE TRANSACTIONS ON MAGNETICS, 2004, 40 (04) : 2428 - 2430
  • [35] The Control of Renewable Energies to Improve the Performance of Multisource Heat Pump Systems: A Two-Case Study
    Busato, Filippo
    Lazzarin, Renato
    Noro, Marco
    APPLIED SCIENCES-BASEL, 2021, 11 (14):
  • [36] Comparison of two different configurations of multi-pass amplifier for chirped pulse amplification
    Ruiz-de la Cruz, A
    Rangel-Rojo, R
    RIAO/OPTILAS 2004: 5TH IBEROAMERICAN MEETING ON OPTICS AND 8TH LATIN AMERICAN MEETING ON OPTICS, LASERS, AND THEIR APPLICATIONS, PTS 1-3: ICO REGIONAL MEETING, 2004, 5622 : 354 - 357
  • [37] Comparison of Different Configurations for the Implantable Capacitive Intrabody Communication on a Two-Layer Phantom
    Roglic, Matija
    Klaic, Luka
    Wei, Ziliang
    Gao, Yueming
    Vasic, Zeljka Lucev
    9TH EUROPEAN MEDICAL AND BIOLOGICAL ENGINEERING CONFERENCE, VOL 1, EMBEC 2024, 2024, 112 : 207 - 216
  • [38] Quantitative Analysis and Performance Comparison of DC PV Power Collection Network with Different Configurations
    Ye, Huili
    Zhu, Miao
    Li, Xiuyi
    Cai, Xu
    IECON 2020: THE 46TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2020, : 1905 - 1910
  • [39] Benefits comparison of vortex instability and aerodynamic performance from different split winglet configurations
    Cheng, Ze-Peng
    Wu, Yi-Ming
    Xiang, Yang
    Liu, Hong
    Wang, Fu-Xin
    AEROSPACE SCIENCE AND TECHNOLOGY, 2021, 119
  • [40] Comparison of Dynamic Performance of Different S-CO2 Brayton Cycle Configurations
    Bian, Xingyan
    Wang, Xuan
    Wang, Rui
    Cai, Jinwen
    Zhang, Xuanang
    Tian, Hua
    Shu, Gequn
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2022, 43 (09): : 2292 - 2298