Ultra-low-field magnetic resonance angiography at 0.05 T: A preliminary study

被引:1
|
作者
Su, Shi [1 ,2 ]
Hu, Jiahao [1 ,2 ]
Ding, Ye [1 ,2 ]
Zhang, Junhao [1 ,2 ]
Lau, Vick [1 ,2 ]
Zhao, Yujiao [1 ,2 ]
Wu, Ed X. [1 ,2 ]
机构
[1] Univ Hong Kong, Lab Biomed Imaging & Signal Proc, Hong Kong, Peoples R China
[2] Univ Hong Kong, Dept Elect & Elect Engn, Hong Kong, Peoples R China
关键词
brain; magnetic resonance angiography; MRI; neck; noncontrast enhancement; time-of-flight; ultra-low-field; THIN SLAB ACQUISITION; MR-ANGIOGRAPHY; NOISE-RATIO; TOF-MRA; DISEASE; VOLUME;
D O I
10.1002/nbm.5213
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We aim to explore the feasibility of head and neck time-of-flight (TOF) magnetic resonance angiography (MRA) at ultra-low-field (ULF). TOF MRA was conducted on a highly simplified 0.05 T MRI scanner with no radiofrequency (RF) and magnetic shielding. A flow-compensated three-dimensional (3D) gradient echo (GRE) sequence with a tilt-optimized nonsaturated excitation RF pulse, and a flow-compensated multislice two-dimensional (2D) GRE sequence, were implemented for cerebral artery and vein imaging, respectively. For carotid artery and jugular vein imaging, flow-compensated 2D GRE sequences were utilized with venous and arterial blood presaturation, respectively. MRA was performed on young healthy subjects. Vessel-to-background contrast was experimentally observed with strong blood inflow effect and background tissue suppression. The large primary cerebral arteries and veins, carotid arteries, jugular veins, and artery bifurcations could be identified in both raw GRE images and maximum intensity projections. The primary brain and neck arteries were found to be reproducible among multiple examination sessions. These preliminary experimental results demonstrated the possibility of artery TOF MRA on low-cost 0.05 T scanners for the first time, despite the extremely low MR signal. We expect to improve the quality of ULF TOF MRA in the near future through sequence development and optimization, ongoing advances in ULF hardware and image formation, and the use of vascular T1 contrast agents. The preliminary feasibility of TOF MRA at 0.05 T was demonstrated for the first time despite the extremely low MR signal. The large primary cerebral arteries and veins, carotid arteries, jugular veins, and artery bifurcations could be identified in both raw GRE images and maximum intensity projections. image
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Unshielded SQUID Sensors for Ultra-Low-Field Magnetic Resonance Imaging
    Luomahaara, Juho
    Kiviranta, Mikko
    Gronberg, Leif
    Zevenhoven, Koos C. J.
    Laine, Petteri
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2018, 28 (04)
  • [2] Design of a Quadrature Receive Coil for Ultra-Low-Field Knee Magnetic Resonance Imaging
    Wan C.
    He W.
    Shen S.
    Xu Z.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2024, 39 (07): : 1923 - 1931
  • [3] ULTRA-LOW-FIELD MAGNETIC-RESONANCE-IMAGING OF ACUTE CRUCIATE LIGAMENT TEARS
    EKELUND, L
    BJORNEBRINK, J
    ELMQVIST, LG
    MAGNETIC RESONANCE IMAGING, 1991, 9 (02) : 179 - 185
  • [4] Portable ultra-low-field magnetic resonance imaging enables postictal seizure imaging
    Bauer, Tobias
    Sabir, Hemmen
    Baumgartner, Tobias
    Racz, Attila
    Pukropski, Jan
    Badr, Mostafa
    Olbrich, Simon
    Lange, Annalena
    Bisten, Justus
    Groteklaes, Anne
    Lehnen, Nils C.
    Cendes, Fernando
    Radbruch, Alexander
    Surges, Rainer
    Rueber, Theodor
    EPILEPSIA, 2025,
  • [5] Conductive shield for ultra-low-field magnetic resonance imaging: Theory and measurements of eddy currents
    Zevenhoven, Koos C. J.
    Busch, Sarah
    Hatridge, Michael
    Oisjoen, Fredrik
    Ilmoniemi, Risto J.
    Clarke, John
    JOURNAL OF APPLIED PHYSICS, 2014, 115 (10)
  • [6] Ultra-low-field magnetic resonance imaging in upper airways obstruction in sleep apnea syndrome
    Okada, T
    Fukatsu, H
    Ishigaki, T
    Yasuma, F
    Kayukawa, Y
    PSYCHIATRY AND CLINICAL NEUROSCIENCES, 1996, 50 (05) : 285 - 289
  • [7] Ultra-low-field MRI using superconductive magnetic sensors
    Kanazawa Institute of Technology, Applied Electronics Laboratory, Kanazawa-shi, Japan
    J. Inst. Electron. Inf. Commun. Eng., 1 (40-47):
  • [8] Performance study of aluminum shielded room for ultra-low-field magnetic resonance imaging based on SQUID:Simulations and experiments
    李波
    董慧
    黄小磊
    邱阳
    陶泉
    朱建明
    Chinese Physics B, 2018, 27 (02) : 277 - 283
  • [9] Performance study of aluminum shielded room for ultra-low-field magnetic resonance imaging based on SQUID: Simulations and experiments
    Li, Bo
    Dong, Hui
    Huang, Xiao-Lei
    Qiu, Yang
    Tao, Quan
    Zhu, Jian-Ming
    CHINESE PHYSICS B, 2018, 27 (02)
  • [10] Multiple sclerosis lesion burden estimates using portable ultra-low-field magnetic resonance imaging
    Arnold, T. C.
    Tu, D.
    Okar, S.
    Nair, G.
    By, S.
    Kawatra, K.
    Robert-Fitzgerald, T.
    Desiderio, L.
    Schindler, M.
    Litt, B.
    Shinohara, R.
    Reich, D.
    Stein, J.
    MULTIPLE SCLEROSIS JOURNAL, 2021, 27 (2_SUPPL) : 420 - 420