Performance study of aluminum shielded room for ultra-low-field magnetic resonance imaging based on SQUID:Simulations and experiments

被引:0
|
作者
李波 [1 ,2 ,3 ]
董慧 [2 ,3 ]
黄小磊 [2 ,3 ,4 ]
邱阳 [1 ,2 ,3 ]
陶泉 [2 ,3 ]
朱建明 [1 ]
机构
[1] China Jiliang University
[2] State Key Laboratory of Functional Materials for Informatics, Shanghai Institute of Microsystem and Information Technology (SIMIT),Chinese Academy of Sciences (CAS)
[3] CAS Center for Excelle Nce in Superconducting Electronics (CENSE)
[4] University of Chinese Academy of Sciences
基金
中国国家自然科学基金;
关键词
shielding effectiveness; aluminum shielded room; eddy current cancellation technique; superconducting quantum interference device; ultra-low-field magnetic resonance imaging;
D O I
暂无
中图分类号
O482.531 [];
学科分类号
070205 ; 0805 ; 080502 ; 0809 ;
摘要
The aluminum shielded room has been an important part of ultra-low-field magnetic resonance imaging(ULF MRI)based on the superconducting quantum interference device(SQUID). The shielded room is effective to attenuate the external radio-frequency field and keep the extremely sensitive detector, SQUID, working properly. A high-performance shielded room can increase the signal-to-noise ratio(SNR) and improve image quality. In this study, a circular coil with a diameter of 50 cm and a square coil with a side length of 2.0 m was used to simulate the magnetic fields from the nearby electric apparatuses and the distant environmental noise sources. The shielding effectivenesses(SE) of the shielded room with different thicknesses of aluminum sheets were calculated and simulated. A room using 6-mm-thick aluminum plates with a dimension of 1.5 m×1.5 m×2.0 m was then constructed. The SE was experimentally measured by using three-axis SQUID magnetometers, with tranisent magnetic field induced in the aluminum plates by the strong pre-polarization pulses. The results of the measured SE agreed with that from the simulation. In addition, the introduction of a 0.5-mm gap caused the obvious reduction of SE indicating the importance of door design. The nuclear magnetic resonance(NMR) signals of water at 5.9 kHz were measured in free space and in a shielded room, and the SNR was improved from 3 to 15. The simulation and experimental results will help us design an aluminum shielded room which satisfies the requirements for future ULF human brain imaging. Finally, the cancellation technique of the transient eddy current was tried, the simulation of the cancellation technique will lead us to finding an appropriate way to suppress the eddy current fields.
引用
收藏
页码:277 / 283
页数:7
相关论文
共 50 条
  • [1] Performance study of aluminum shielded room for ultra-low-field magnetic resonance imaging based on SQUID: Simulations and experiments
    Li, Bo
    Dong, Hui
    Huang, Xiao-Lei
    Qiu, Yang
    Tao, Quan
    Zhu, Jian-Ming
    CHINESE PHYSICS B, 2018, 27 (02)
  • [2] Unshielded SQUID Sensors for Ultra-Low-Field Magnetic Resonance Imaging
    Luomahaara, Juho
    Kiviranta, Mikko
    Gronberg, Leif
    Zevenhoven, Koos C. J.
    Laine, Petteri
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2018, 28 (04)
  • [3] Dynamical cancellation of pulse-induced transients in a metallic shielded room for ultra-low-field magnetic resonance imaging
    Zevenhoven, Koos C. J.
    Dong, Hui
    Ilmoniemi, Risto J.
    Clarke, John
    APPLIED PHYSICS LETTERS, 2015, 106 (03)
  • [4] Portable ultra-low-field magnetic resonance imaging enables postictal seizure imaging
    Bauer, Tobias
    Sabir, Hemmen
    Baumgartner, Tobias
    Racz, Attila
    Pukropski, Jan
    Badr, Mostafa
    Olbrich, Simon
    Lange, Annalena
    Bisten, Justus
    Groteklaes, Anne
    Lehnen, Nils C.
    Cendes, Fernando
    Radbruch, Alexander
    Surges, Rainer
    Rueber, Theodor
    EPILEPSIA, 2025,
  • [5] Design of a Quadrature Receive Coil for Ultra-Low-Field Knee Magnetic Resonance Imaging
    Wan C.
    He W.
    Shen S.
    Xu Z.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2024, 39 (07): : 1923 - 1931
  • [6] ULTRA-LOW-FIELD MAGNETIC-RESONANCE-IMAGING OF ACUTE CRUCIATE LIGAMENT TEARS
    EKELUND, L
    BJORNEBRINK, J
    ELMQVIST, LG
    MAGNETIC RESONANCE IMAGING, 1991, 9 (02) : 179 - 185
  • [7] Ultra-low-field magnetic resonance angiography at 0.05 T: A preliminary study
    Su, Shi
    Hu, Jiahao
    Ding, Ye
    Zhang, Junhao
    Lau, Vick
    Zhao, Yujiao
    Wu, Ed X.
    NMR IN BIOMEDICINE, 2024, 37 (11)
  • [8] Pre-polarization enhancement by dynamic nuclear polarization in SQUID-based ultra-low-field nuclear magnetic resonance
    Lee, Seong-Joo
    Kim, Kiwoong
    Kang, Chan Seok
    Hwang, Seong-min
    Lee, Yong-Ho
    SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2010, 23 (11):
  • [9] Conductive shield for ultra-low-field magnetic resonance imaging: Theory and measurements of eddy currents
    Zevenhoven, Koos C. J.
    Busch, Sarah
    Hatridge, Michael
    Oisjoen, Fredrik
    Ilmoniemi, Risto J.
    Clarke, John
    JOURNAL OF APPLIED PHYSICS, 2014, 115 (10)
  • [10] Ultra-low-field magnetic resonance imaging in upper airways obstruction in sleep apnea syndrome
    Okada, T
    Fukatsu, H
    Ishigaki, T
    Yasuma, F
    Kayukawa, Y
    PSYCHIATRY AND CLINICAL NEUROSCIENCES, 1996, 50 (05) : 285 - 289