Performance study of aluminum shielded room for ultra-low-field magnetic resonance imaging based on SQUID:Simulations and experiments

被引:0
|
作者
李波 [1 ,2 ,3 ]
董慧 [2 ,3 ]
黄小磊 [2 ,3 ,4 ]
邱阳 [1 ,2 ,3 ]
陶泉 [2 ,3 ]
朱建明 [1 ]
机构
[1] China Jiliang University
[2] State Key Laboratory of Functional Materials for Informatics, Shanghai Institute of Microsystem and Information Technology (SIMIT),Chinese Academy of Sciences (CAS)
[3] CAS Center for Excelle Nce in Superconducting Electronics (CENSE)
[4] University of Chinese Academy of Sciences
基金
中国国家自然科学基金;
关键词
shielding effectiveness; aluminum shielded room; eddy current cancellation technique; superconducting quantum interference device; ultra-low-field magnetic resonance imaging;
D O I
暂无
中图分类号
O482.531 [];
学科分类号
070205 ; 0805 ; 080502 ; 0809 ;
摘要
The aluminum shielded room has been an important part of ultra-low-field magnetic resonance imaging(ULF MRI)based on the superconducting quantum interference device(SQUID). The shielded room is effective to attenuate the external radio-frequency field and keep the extremely sensitive detector, SQUID, working properly. A high-performance shielded room can increase the signal-to-noise ratio(SNR) and improve image quality. In this study, a circular coil with a diameter of 50 cm and a square coil with a side length of 2.0 m was used to simulate the magnetic fields from the nearby electric apparatuses and the distant environmental noise sources. The shielding effectivenesses(SE) of the shielded room with different thicknesses of aluminum sheets were calculated and simulated. A room using 6-mm-thick aluminum plates with a dimension of 1.5 m×1.5 m×2.0 m was then constructed. The SE was experimentally measured by using three-axis SQUID magnetometers, with tranisent magnetic field induced in the aluminum plates by the strong pre-polarization pulses. The results of the measured SE agreed with that from the simulation. In addition, the introduction of a 0.5-mm gap caused the obvious reduction of SE indicating the importance of door design. The nuclear magnetic resonance(NMR) signals of water at 5.9 kHz were measured in free space and in a shielded room, and the SNR was improved from 3 to 15. The simulation and experimental results will help us design an aluminum shielded room which satisfies the requirements for future ULF human brain imaging. Finally, the cancellation technique of the transient eddy current was tried, the simulation of the cancellation technique will lead us to finding an appropriate way to suppress the eddy current fields.
引用
收藏
页码:277 / 283
页数:7
相关论文
共 50 条
  • [21] Sensitivity of portable ultra-low-field magnetic resonance imaging for white matter lesions, dissemination in space, and dissemination in time
    Okar, S. V.
    Nair, G.
    Kawatra, K. D.
    Arnold, T. C.
    Shinohara, R. T.
    Stein, J. M.
    Reich, D. S.
    MULTIPLE SCLEROSIS JOURNAL, 2022, 28 (3_SUPPL) : 288 - 289
  • [22] Noise amplification in parallel whole-head ultra-low-field magnetic resonance imaging using 306 detectors
    Lin, Fa-Hsuan
    Vesanen, Panu T.
    Nieminen, Jaakko O.
    Hsu, Yi-Cheng
    Zevenhoven, Koos C. J.
    Dabek, Juhani
    Parkkonen, Lauri T.
    Zhdanov, Andrey
    Ilmoniemi, Risto J.
    MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (02) : 595 - 600
  • [23] Development of Ultra Low Field Nuclear Magnetic Resonance Imaging System Using HTS rf SQUID
    Snigirev, O.
    Hayashi, M.
    Fukumoto, S.
    Hatsukade, Y.
    Katsu, Y.
    Tanaka, S.
    JOURNAL OF SUPERCONDUCTIVITY AND NOVEL MAGNETISM, 2011, 24 (1-2) : 1033 - 1036
  • [24] Development of Ultra Low Field Nuclear Magnetic Resonance Imaging System Using HTS rf SQUID
    O. Snigirev
    M. Hayashi
    S. Fukumoto
    Y. Hatsukade
    Y. Katsu
    S. Tanaka
    Journal of Superconductivity and Novel Magnetism, 2011, 24 : 1033 - 1036
  • [25] Ultra-Low-Field Portable Brain Magnetic Resonance Imaging in Patients With Cardiac Devices: Current Evidence and Future Directions
    Khanduja, Shivalika
    Kang, Jin K.
    Chinedozi, Ifeanyi D.
    Darby, Zachary
    Kim, Jiah
    Whitman, Glenn
    Cho, Sung-Min
    ASAIO JOURNAL, 2025, 71 (04) : 277 - 282
  • [26] ULTRA LOW FIELD MAGNETIC RESONANCE IMAGING EQUIPMENT
    Kumar, Pratik
    JOURNAL OF MEDICAL PHYSICS, 2022, 47 (01) : 117 - 118
  • [27] SQUIDs for Magnetic Resonance Imaging at Ultra-low Magnetic Field
    Matlashov, A. N.
    Zotev, V. S.
    Kraus, R. H., Jr.
    Sandin, H.
    Urbaitis, A. V.
    Volegov, P. L.
    Espy, M. A.
    PIERS 2009 MOSCOW VOLS I AND II, PROCEEDINGS, 2009, : 802 - 806
  • [28] CEREBRAL ABNORMALITIES IN WILSONS-DISEASE AS EVALUATED BY ULTRA-LOW-FIELD MAGNETIC-RESONANCE-IMAGING AND COMPUTERIZED IMAGE-PROCESSING
    LINNE, T
    AGARTZ, I
    SAAF, J
    WAHLUND, LO
    MAGNETIC RESONANCE IMAGING, 1990, 8 (06) : 819 - 824
  • [29] A Systematic Review of the Use of Portable Ultra-Low-Field Magnetic Resonance Imaging in Non-Acute Brain Imaging and Its Potential Use in Dementia Assessment
    Dobrzanski, James
    Townsend, Amelia
    Shergill, Sukhi
    Rodda, Joanne
    BJPSYCH OPEN, 2024, 10 : S31 - S32
  • [30] An advanced phantom study assessing the feasibility of neuronal current imaging by ultra-low-field NMR
    Koerber, Rainer
    Nieminen, Jaakko O.
    Hoefner, Nora
    Jazbinsek, Vojko
    Scheer, Hans-Juergen
    Kim, Kiwoong
    Burghoff, Martin