Ultra-low-field magnetic resonance angiography at 0.05 T: A preliminary study

被引:1
|
作者
Su, Shi [1 ,2 ]
Hu, Jiahao [1 ,2 ]
Ding, Ye [1 ,2 ]
Zhang, Junhao [1 ,2 ]
Lau, Vick [1 ,2 ]
Zhao, Yujiao [1 ,2 ]
Wu, Ed X. [1 ,2 ]
机构
[1] Univ Hong Kong, Lab Biomed Imaging & Signal Proc, Hong Kong, Peoples R China
[2] Univ Hong Kong, Dept Elect & Elect Engn, Hong Kong, Peoples R China
关键词
brain; magnetic resonance angiography; MRI; neck; noncontrast enhancement; time-of-flight; ultra-low-field; THIN SLAB ACQUISITION; MR-ANGIOGRAPHY; NOISE-RATIO; TOF-MRA; DISEASE; VOLUME;
D O I
10.1002/nbm.5213
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We aim to explore the feasibility of head and neck time-of-flight (TOF) magnetic resonance angiography (MRA) at ultra-low-field (ULF). TOF MRA was conducted on a highly simplified 0.05 T MRI scanner with no radiofrequency (RF) and magnetic shielding. A flow-compensated three-dimensional (3D) gradient echo (GRE) sequence with a tilt-optimized nonsaturated excitation RF pulse, and a flow-compensated multislice two-dimensional (2D) GRE sequence, were implemented for cerebral artery and vein imaging, respectively. For carotid artery and jugular vein imaging, flow-compensated 2D GRE sequences were utilized with venous and arterial blood presaturation, respectively. MRA was performed on young healthy subjects. Vessel-to-background contrast was experimentally observed with strong blood inflow effect and background tissue suppression. The large primary cerebral arteries and veins, carotid arteries, jugular veins, and artery bifurcations could be identified in both raw GRE images and maximum intensity projections. The primary brain and neck arteries were found to be reproducible among multiple examination sessions. These preliminary experimental results demonstrated the possibility of artery TOF MRA on low-cost 0.05 T scanners for the first time, despite the extremely low MR signal. We expect to improve the quality of ULF TOF MRA in the near future through sequence development and optimization, ongoing advances in ULF hardware and image formation, and the use of vascular T1 contrast agents. The preliminary feasibility of TOF MRA at 0.05 T was demonstrated for the first time despite the extremely low MR signal. The large primary cerebral arteries and veins, carotid arteries, jugular veins, and artery bifurcations could be identified in both raw GRE images and maximum intensity projections. image
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Denoise ultra-low-field 3D magnetic resonance images using a joint signal-image domain filter
    Zhang, Yuxiang
    He, Wei
    Chen, Fangge
    Wu, Jiamin
    He, Yucheng
    Xu, Zheng
    JOURNAL OF MAGNETIC RESONANCE, 2022, 344
  • [32] CEREBRAL ABNORMALITIES IN WILSONS-DISEASE AS EVALUATED BY ULTRA-LOW-FIELD MAGNETIC-RESONANCE-IMAGING AND COMPUTERIZED IMAGE-PROCESSING
    LINNE, T
    AGARTZ, I
    SAAF, J
    WAHLUND, LO
    MAGNETIC RESONANCE IMAGING, 1990, 8 (06) : 819 - 824
  • [33] ULTRA LOW FIELD MAGNETIC RESONANCE IMAGING EQUIPMENT
    Kumar, Pratik
    JOURNAL OF MEDICAL PHYSICS, 2022, 47 (01) : 117 - 118
  • [34] Optical Atomic Magnetometry for Ultra-Low-Field NMR Detection
    Bevilacqua, G.
    Biancalana, V.
    Dancheva, Y.
    Moi, L.
    ANNUAL REPORTS ON NMR SPECTROSCOPY, VOL 78, 2013, 78 : 103 - 148
  • [35] SQUIDs for Magnetic Resonance Imaging at Ultra-low Magnetic Field
    Matlashov, A. N.
    Zotev, V. S.
    Kraus, R. H., Jr.
    Sandin, H.
    Urbaitis, A. V.
    Volegov, P. L.
    Espy, M. A.
    PIERS 2009 MOSCOW VOLS I AND II, PROCEEDINGS, 2009, : 802 - 806
  • [36] Safety in Simultaneous Ultra-Low-Field MRI and MEG: Forces Exerted on Magnetizable Objects by Magnetic Fields
    Dabek, Juhani
    Sannholm, Fredrik
    Nieminen, Jaakko O.
    Vesanen, Panu T.
    Ilmoniemi, Risto J.
    17TH INTERNATIONAL CONFERENCE ON BIOMAGNETISM ADVANCES IN BIOMAGNETISM - BIOMAG2010, 2010, 28 : 74 - 77
  • [37] Gradient Coil Design and Optimization for an Ultra-Low-Field MRI System
    Shen, Sheng
    Koonjoo, Neha
    Kong, Xiaohan
    Rosen, Matthew S.
    Xu, Zheng
    APPLIED MAGNETIC RESONANCE, 2022, 53 (06) : 895 - 914
  • [38] Simulation and Optimization Study of an Ultra-Low-Field Bell-Shaped Head MRI Electromagnet
    Ye Ding
    Pan Guo
    Jiamin Wu
    Yucheng He
    Zheng Xu
    Applied Magnetic Resonance, 2021, 52 : 691 - 704
  • [39] Simulation and Optimization Study of an Ultra-Low-Field Bell-Shaped Head MRI Electromagnet
    Ding, Ye
    Guo, Pan
    Wu, Jiamin
    He, Yucheng
    Xu, Zheng
    APPLIED MAGNETIC RESONANCE, 2021, 52 (06) : 691 - 704
  • [40] Graphene quantum dots-based magnetic relaxation switch involving magnetic separation for enhanced performances of endoglin detection using ultra-low-field nuclear magnetic resonance relaxometry
    Li, Yongqiang
    Shi, Zhifeng
    Shang, Liuyang
    Tao, Quan
    Tang, Qisheng
    Krause, Hans-Joachim
    Yang, Siwei
    Ding, Guqiao
    Dong, Hui
    SENSORS AND ACTUATORS B-CHEMICAL, 2023, 380