Ultra-low-field magnetic resonance angiography at 0.05 T: A preliminary study

被引:1
|
作者
Su, Shi [1 ,2 ]
Hu, Jiahao [1 ,2 ]
Ding, Ye [1 ,2 ]
Zhang, Junhao [1 ,2 ]
Lau, Vick [1 ,2 ]
Zhao, Yujiao [1 ,2 ]
Wu, Ed X. [1 ,2 ]
机构
[1] Univ Hong Kong, Lab Biomed Imaging & Signal Proc, Hong Kong, Peoples R China
[2] Univ Hong Kong, Dept Elect & Elect Engn, Hong Kong, Peoples R China
关键词
brain; magnetic resonance angiography; MRI; neck; noncontrast enhancement; time-of-flight; ultra-low-field; THIN SLAB ACQUISITION; MR-ANGIOGRAPHY; NOISE-RATIO; TOF-MRA; DISEASE; VOLUME;
D O I
10.1002/nbm.5213
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We aim to explore the feasibility of head and neck time-of-flight (TOF) magnetic resonance angiography (MRA) at ultra-low-field (ULF). TOF MRA was conducted on a highly simplified 0.05 T MRI scanner with no radiofrequency (RF) and magnetic shielding. A flow-compensated three-dimensional (3D) gradient echo (GRE) sequence with a tilt-optimized nonsaturated excitation RF pulse, and a flow-compensated multislice two-dimensional (2D) GRE sequence, were implemented for cerebral artery and vein imaging, respectively. For carotid artery and jugular vein imaging, flow-compensated 2D GRE sequences were utilized with venous and arterial blood presaturation, respectively. MRA was performed on young healthy subjects. Vessel-to-background contrast was experimentally observed with strong blood inflow effect and background tissue suppression. The large primary cerebral arteries and veins, carotid arteries, jugular veins, and artery bifurcations could be identified in both raw GRE images and maximum intensity projections. The primary brain and neck arteries were found to be reproducible among multiple examination sessions. These preliminary experimental results demonstrated the possibility of artery TOF MRA on low-cost 0.05 T scanners for the first time, despite the extremely low MR signal. We expect to improve the quality of ULF TOF MRA in the near future through sequence development and optimization, ongoing advances in ULF hardware and image formation, and the use of vascular T1 contrast agents. The preliminary feasibility of TOF MRA at 0.05 T was demonstrated for the first time despite the extremely low MR signal. The large primary cerebral arteries and veins, carotid arteries, jugular veins, and artery bifurcations could be identified in both raw GRE images and maximum intensity projections. image
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Ultra-Low-Field Portable Brain Magnetic Resonance Imaging in Patients With Cardiac Devices: Current Evidence and Future Directions
    Khanduja, Shivalika
    Kang, Jin K.
    Chinedozi, Ifeanyi D.
    Darby, Zachary
    Kim, Jiah
    Whitman, Glenn
    Cho, Sung-Min
    ASAIO JOURNAL, 2025, 71 (04) : 277 - 282
  • [22] Ultra-low-noise amplifier for ultra-low-field MRI main field and gradients
    Zevenhoven, Koos C. J.
    Alanko, Sarianna
    11TH EUROPEAN CONFERENCE ON APPLIED SUPERCONDUCTIVITY (EUCAS2013), PTS 1-4, 2014, 507
  • [23] Rotary Scanning Acquisition in Ultra-Low-Field MRI
    Hsu, Yi-Cheng
    Zevenhoven, Koos C. J.
    Chu, Ying-Hua
    Dabek, Juhani
    Ilmoniemi, Risto J.
    Lin, Fa-Hsuan
    MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (06) : 2255 - 2264
  • [24] Ultra-low-field MRI for the detection of liquid explosives
    Espy, M.
    Flynn, M.
    Gomez, J.
    Hanson, C.
    Kraus, R.
    Magnelind, P.
    Maskaly, K.
    Matlashov, A.
    Newman, S.
    Owens, T.
    Peters, M.
    Sandin, H.
    Savukov, I.
    Schultz, L.
    Urbaitis, A.
    Volegov, P.
    Zotev, V.
    SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2010, 23 (03):
  • [25] Investigation of Magnetic Interference Induced via Gradient Field Coils for Ultra-Low-Field MRI Systems
    Oyama, D.
    Hatta, J.
    Miyamoto, M.
    Adachi, Y.
    Higuchi, M.
    Kawai, J.
    Fujihira, J.
    Tsuyuguchi, N.
    Uehara, G.
    11TH EUROPEAN CONFERENCE ON APPLIED SUPERCONDUCTIVITY (EUCAS2013), PTS 1-4, 2014, 507
  • [26] Pre-polarization enhancement by dynamic nuclear polarization in SQUID-based ultra-low-field nuclear magnetic resonance
    Lee, Seong-Joo
    Kim, Kiwoong
    Kang, Chan Seok
    Hwang, Seong-min
    Lee, Yong-Ho
    SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2010, 23 (11):
  • [27] MAGNETIC-RESONANCE-IMAGING OF THE UTERUS AT AN ULTRA LOW (0.02 T) MAGNETIC-FIELD
    VARPULA, M
    KOMU, M
    KLEMI, P
    MAGNETIC RESONANCE IMAGING, 1992, 10 (02) : 195 - 205
  • [28] Ultra-low-field magnetization transfer imaging at 0.055T with low specific absorption rate
    Su, Shi
    Zhao, Yujiao
    Ding, Ye
    Lau, Vick
    Xiao, Linfang
    Leung, Gilberto K. K.
    Lau, Gary K. K.
    Huang, Fan
    Vardhanabhuti, Vince
    Leong, Alex T. L.
    Wu, Ed X.
    MAGNETIC RESONANCE IN MEDICINE, 2024, 92 (06) : 2420 - 2432
  • [29] Solving the problem of concomitant gradients in ultra-low-field MRI
    Nieminen, Jaakko O.
    Ilmoniemi, Risto J.
    JOURNAL OF MAGNETIC RESONANCE, 2010, 207 (02) : 213 - 219
  • [30] Increase of nuclear magnetic resonance signal in ultra-low-field by hyperpolarization of 131Xe by spin-exchange optical pumping
    Takeda S.
    Kumagai H.
    IEEJ Transactions on Electronics, Information and Systems, 2017, 137 (04) : 604 - 606