Glucose oxidase, horseradish peroxidase and phenothiazine dyes-co-adsorbed carbon felt-based amperometric flow-biosensor for glucose

被引:1
|
作者
Jiao, Zeting [1 ]
Kuang, Lichuan [1 ]
Komori, Masahito [1 ]
Hirono, Masaki [2 ]
Komuro, Ryota [2 ]
Wang, Yue [3 ]
Hasebe, Yasushi [1 ,2 ]
机构
[1] Saitama Inst Technol, Grad Sch Engn, Dept Life Sci & Green Chem, 1690 Fukaya, Saitama 3690293, Japan
[2] Saitama Inst Technol, Fac Engn, Dept Life Sci & Green Chem, 1690 Fukaya, Saitama 3690293, Japan
[3] Univ Sci & Technol LiaoNing, Sch Chem Engn, Anshan 114501, Liaoning, Peoples R China
关键词
SCREEN-PRINTED ELECTRODE; METHYLENE-BLUE; INJECTION ANALYSIS; PROTEIN ADSORPTION; HYDROGEN-PEROXIDE; OXIDATION; SYSTEM; SURFACE; MECHANISM; IMMOBILIZATION;
D O I
10.1039/d4ay01028k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
To develop an amperometric flow-biosensor for glucose, the stabilizing effect of methylene blue (MB) toward adsorbed glucose oxidase (GOx) on carbon felt (CF) was successfully applied to prepare the GOx-modified CF-based enzyme reactor combined with a horseradish peroxidase (HRP)-modified CF-based H2O2 detector. Upon mixing MB in the GOx-adsorption solution, the O2-dependent GOx-activity was significantly increased with increasing concentration of MB in the GOx-adsorption solution. The GOx-immobilization protocol on CF is very straightforward [i.e., adsorption of the GOx/MB mixed aqueous solution for 5 min under ultrasound (US)-irradiation]. Under the optimized operational conditions (i.e., applied potential, 0 vs. Ag/AgCl; carrier pH, 5.0; carrier flow rate, 4.0 mL min-1), the resulting GOx/MB-CF-reactor and HRP/TN-CF-detector combined amperometric flow-biosensor exhibited sensitive, selective, reproducible and stable cathodic peak current responses to glucose with the following analytical performances: sensitivity, 6.22 mu A mM-1; linear range, 0.01 to 1 mM; limit of detection, 9.6 mu M (S/N = 3, noise level, 20 nA); sample throughput, 46-96 samples per h for 10-0.1 mM glucose. The developed amperometric flow-biosensor allowed the determination of glucose in beverages and liquors, and the analytical results by the sensor were in fairly good agreement with those by conventional spectrophotometry. Based on the stabilizing effect of methylene blue toward glucose oxidase (GOx), amperometric flow-biosensor for glucose was developed by the combination of GOx-adsorbed carbon felt (CF)-reactor and peroxidase-adsorbed CF-based H2O2 detector.
引用
收藏
页码:5883 / 5895
页数:13
相关论文
共 50 条
  • [31] Native carbon nanodots as a fluorescent probe for assays based on the use of glucose oxidase or horseradish peroxidase
    Fang, Xin
    Wu, Xiu-Ming
    Hu, Xue-Lian
    Li, Zai-Jun
    Wang, Guang-Li
    MICROCHIMICA ACTA, 2016, 183 (10) : 2761 - 2770
  • [32] Native carbon nanodots as a fluorescent probe for assays based on the use of glucose oxidase or horseradish peroxidase
    Xin Fang
    Xiu-Ming Wu
    Xue-Lian Hu
    Zai-Jun Li
    Guang-Li Wang
    Microchimica Acta, 2016, 183 : 2761 - 2770
  • [33] Flow-injection determination of trace hydrogen peroxide or glucose utilizing an amperometric biosensor based on glucose oxidase bound to a reticulated vitreous carbon electrode
    Khayyami, M
    Johansson, G
    Kriz, D
    Xie, B
    Larsson, PO
    Danielsson, B
    TALANTA, 1996, 43 (06) : 957 - 962
  • [34] Design of an Amperometric Glucose Biosensor Based on Glucose Oxidase/Arginated-Fe3O4/Glassy Carbon Electrode
    Krishna, Rahul
    Chandra, Sudeshna
    Bardhan, Neelkanth
    Salimian, Maryam
    Yang, Y. Y.
    Titus, Elby
    Gracio, Jose
    Bahadur, Dhirendra
    SCIENCE OF ADVANCED MATERIALS, 2013, 5 (04) : 333 - 340
  • [35] Amperometric biosensor sensitive to glucose and lactose based on co-immobilization of ferrocene, glucose oxidase, β-galactosidase and mutarotase in β-cyclodextrin polymer
    Liu, HY
    Li, HH
    Ying, TL
    Sun, K
    Qin, YQ
    Qi, DY
    ANALYTICA CHIMICA ACTA, 1998, 358 (02) : 137 - 144
  • [36] Amperometric biosensor sensitive to glucose and lactose based on co-immobilization of ferrocene, glucose oxidase, β-galactosidase and mutarotase in β-cyclodextrin polymer
    Department of Chemistry and Chemical Engineering, Shanghai University, Shanghai
    200072, China
    不详
    Zhejiang Province
    310016, China
    Analytica Chimica Acta, 1999, 358 (02): : 137 - 144
  • [37] Carbon Felt-Based Bioelectrocatalytic Flow-Through Detectors: 2,6-Dichlorophenol Indophenol and Peroxidase Coadsorbed Carbon-Felt for Flow-Amperometric Determination of Hydrogen Peroxide
    Wang, Yue
    Hasebe, Yasushi
    MATERIALS, 2014, 7 (02) : 1142 - 1154
  • [38] Amperometric glucose biosensor based on glucose oxidase encapsulated in carbon nanotube-titania-nafion composite film on platinized glassy carbon electrode
    Choi, Han Nim
    Han, Jee Hoon
    Park, Ji Ae
    Lee, Joong Min
    Lee, Won-Yong
    ELECTROANALYSIS, 2007, 19 (17) : 1757 - 1763
  • [39] Glucose determination in blood samples using flow injection analysis and an amperometric biosensor based on glucose oxidase immobilized on hexacyanoferrate modified nickel electrode
    Milardovic, S
    Kruhak, I
    Ivekovic, D
    Rumenjak, V
    Tkalcec, M
    Grabaric, BS
    ANALYTICA CHIMICA ACTA, 1997, 350 (1-2) : 91 - 96
  • [40] An amperometric glucose biosensor based on glucose oxidase immobilized in electropolymerized poly(o-aminophenol) and carbon nanotubes composite film on a gold electrode
    Pan, DW
    Chen, JH
    Yao, SZ
    Tao, WY
    Nie, LH
    ANALYTICAL SCIENCES, 2005, 21 (04) : 367 - 371