Glucose oxidase, horseradish peroxidase and phenothiazine dyes-co-adsorbed carbon felt-based amperometric flow-biosensor for glucose

被引:1
|
作者
Jiao, Zeting [1 ]
Kuang, Lichuan [1 ]
Komori, Masahito [1 ]
Hirono, Masaki [2 ]
Komuro, Ryota [2 ]
Wang, Yue [3 ]
Hasebe, Yasushi [1 ,2 ]
机构
[1] Saitama Inst Technol, Grad Sch Engn, Dept Life Sci & Green Chem, 1690 Fukaya, Saitama 3690293, Japan
[2] Saitama Inst Technol, Fac Engn, Dept Life Sci & Green Chem, 1690 Fukaya, Saitama 3690293, Japan
[3] Univ Sci & Technol LiaoNing, Sch Chem Engn, Anshan 114501, Liaoning, Peoples R China
关键词
SCREEN-PRINTED ELECTRODE; METHYLENE-BLUE; INJECTION ANALYSIS; PROTEIN ADSORPTION; HYDROGEN-PEROXIDE; OXIDATION; SYSTEM; SURFACE; MECHANISM; IMMOBILIZATION;
D O I
10.1039/d4ay01028k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
To develop an amperometric flow-biosensor for glucose, the stabilizing effect of methylene blue (MB) toward adsorbed glucose oxidase (GOx) on carbon felt (CF) was successfully applied to prepare the GOx-modified CF-based enzyme reactor combined with a horseradish peroxidase (HRP)-modified CF-based H2O2 detector. Upon mixing MB in the GOx-adsorption solution, the O2-dependent GOx-activity was significantly increased with increasing concentration of MB in the GOx-adsorption solution. The GOx-immobilization protocol on CF is very straightforward [i.e., adsorption of the GOx/MB mixed aqueous solution for 5 min under ultrasound (US)-irradiation]. Under the optimized operational conditions (i.e., applied potential, 0 vs. Ag/AgCl; carrier pH, 5.0; carrier flow rate, 4.0 mL min-1), the resulting GOx/MB-CF-reactor and HRP/TN-CF-detector combined amperometric flow-biosensor exhibited sensitive, selective, reproducible and stable cathodic peak current responses to glucose with the following analytical performances: sensitivity, 6.22 mu A mM-1; linear range, 0.01 to 1 mM; limit of detection, 9.6 mu M (S/N = 3, noise level, 20 nA); sample throughput, 46-96 samples per h for 10-0.1 mM glucose. The developed amperometric flow-biosensor allowed the determination of glucose in beverages and liquors, and the analytical results by the sensor were in fairly good agreement with those by conventional spectrophotometry. Based on the stabilizing effect of methylene blue toward glucose oxidase (GOx), amperometric flow-biosensor for glucose was developed by the combination of GOx-adsorbed carbon felt (CF)-reactor and peroxidase-adsorbed CF-based H2O2 detector.
引用
收藏
页码:5883 / 5895
页数:13
相关论文
共 50 条
  • [21] Enhanced amperometric response of a glucose oxidase and horseradish peroxidase based bienzyme glucose biosensor modified with a film of polymerized toluidine blue containing reduced graphene oxide
    Fang Wang
    Wencheng Gong
    Lili Wang
    Zilin Chen
    Microchimica Acta, 2015, 182 : 1949 - 1956
  • [22] Enhanced amperometric response of a glucose oxidase and horseradish peroxidase based bienzyme glucose biosensor modified with a film of polymerized toluidine blue containing reduced graphene oxide
    Wang, Fang
    Gong, Wencheng
    Wang, Lili
    Chen, Zilin
    MICROCHIMICA ACTA, 2015, 182 (11-12) : 1949 - 1956
  • [23] Amperometric glucose biosensor based on integration of glucose oxidase with platinum nanoparticles/ordered mesoporous carbon nanocomposite
    Jiang, Xiaoyan
    Wu, Yanhui
    Mao, Xuyan
    Cui, Xiujun
    Zhu, Liande
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 153 (01) : 158 - 163
  • [24] Development of amperometric glucose biosensor based on glucose oxidase co-immobilized with multi-walled carbon nanotubes at low potential
    Rahman, M. M.
    Umar, Ahmad
    Sawada, Kazuaki
    SENSORS AND ACTUATORS B-CHEMICAL, 2009, 137 (01): : 327 - 333
  • [25] Amperometric glucose biosensor based on glucose oxidase dispersed in multiwalled carbon nanotubes/graphene oxide hybrid biocomposite
    Palanisamy, Selvakumar
    Cheemalapati, Srikanth
    Chen, Shen-Ming
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2014, 34 : 207 - 213
  • [26] Amperometric glucose biosensor based on adsorption of glucose oxidase at platinum nanoparticle-modified carbon nanotube electrode
    Tang, H
    Chen, JH
    Yao, SZ
    Nie, LH
    Deng, GH
    Kuang, YF
    ANALYTICAL BIOCHEMISTRY, 2004, 331 (01) : 89 - 97
  • [27] A bienzymatic amperometric glucose biosensor based on using a novel recombinant Mn peroxidase from corn and glucose oxidase with a Nafion membrane
    Izadyar, Anahita
    Van, My Ni
    Rodriguez, Kayleigh Amber
    Seok, Ilwoo
    Hood, Elizabeth E.
    Journal of Electroanalytical Chemistry, 2021, 895
  • [28] A bienzymatic amperometric glucose biosensor based on using a novel recombinant Mn peroxidase from corn and glucose oxidase with a Nafion membrane
    Izadyar, Anahita
    Van, My Ni
    Rodriguez, Kayleigh Amber
    Seok, Ilwoo
    Hood, Elizabeth E.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2021, 895
  • [29] Amperometric glucose biosensor based on immobilization of glucose oxidase on a magnetic glassy carbon electrode modified with a novel magnetic nanocomposite
    Baghayeri, Mehdi
    Veisi, Hojat
    Ghanei-Motlagh, Masoud
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 249 : 321 - 330
  • [30] Amperometric Glucose Biosensor Based on Glucose Oxidase, 1,10-Phenanthroline-5,6-dione and Carbon Nanotubes
    Zor, Erhan
    Oztekin, Yasemin
    Ramanaviciene, Almira
    Anusevicius, Zilvinas
    Bingol, Haluk
    Barkauskas, Jurgis
    Ersoz, Mustafa
    Ramanavicius, Arunas
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2014, 161 (13) : H3064 - H3069