Glucose oxidase, horseradish peroxidase and phenothiazine dyes-co-adsorbed carbon felt-based amperometric flow-biosensor for glucose

被引:1
|
作者
Jiao, Zeting [1 ]
Kuang, Lichuan [1 ]
Komori, Masahito [1 ]
Hirono, Masaki [2 ]
Komuro, Ryota [2 ]
Wang, Yue [3 ]
Hasebe, Yasushi [1 ,2 ]
机构
[1] Saitama Inst Technol, Grad Sch Engn, Dept Life Sci & Green Chem, 1690 Fukaya, Saitama 3690293, Japan
[2] Saitama Inst Technol, Fac Engn, Dept Life Sci & Green Chem, 1690 Fukaya, Saitama 3690293, Japan
[3] Univ Sci & Technol LiaoNing, Sch Chem Engn, Anshan 114501, Liaoning, Peoples R China
关键词
SCREEN-PRINTED ELECTRODE; METHYLENE-BLUE; INJECTION ANALYSIS; PROTEIN ADSORPTION; HYDROGEN-PEROXIDE; OXIDATION; SYSTEM; SURFACE; MECHANISM; IMMOBILIZATION;
D O I
10.1039/d4ay01028k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
To develop an amperometric flow-biosensor for glucose, the stabilizing effect of methylene blue (MB) toward adsorbed glucose oxidase (GOx) on carbon felt (CF) was successfully applied to prepare the GOx-modified CF-based enzyme reactor combined with a horseradish peroxidase (HRP)-modified CF-based H2O2 detector. Upon mixing MB in the GOx-adsorption solution, the O2-dependent GOx-activity was significantly increased with increasing concentration of MB in the GOx-adsorption solution. The GOx-immobilization protocol on CF is very straightforward [i.e., adsorption of the GOx/MB mixed aqueous solution for 5 min under ultrasound (US)-irradiation]. Under the optimized operational conditions (i.e., applied potential, 0 vs. Ag/AgCl; carrier pH, 5.0; carrier flow rate, 4.0 mL min-1), the resulting GOx/MB-CF-reactor and HRP/TN-CF-detector combined amperometric flow-biosensor exhibited sensitive, selective, reproducible and stable cathodic peak current responses to glucose with the following analytical performances: sensitivity, 6.22 mu A mM-1; linear range, 0.01 to 1 mM; limit of detection, 9.6 mu M (S/N = 3, noise level, 20 nA); sample throughput, 46-96 samples per h for 10-0.1 mM glucose. The developed amperometric flow-biosensor allowed the determination of glucose in beverages and liquors, and the analytical results by the sensor were in fairly good agreement with those by conventional spectrophotometry. Based on the stabilizing effect of methylene blue toward glucose oxidase (GOx), amperometric flow-biosensor for glucose was developed by the combination of GOx-adsorbed carbon felt (CF)-reactor and peroxidase-adsorbed CF-based H2O2 detector.
引用
收藏
页码:5883 / 5895
页数:13
相关论文
共 50 条
  • [1] Mediatorless amperometric bienzyme glucose biosensor based on horseradish peroxidase and glucose oxidase cross-linked to multiwall carbon nanotubes
    Shuxia Xu
    Honglan Qi
    Shiyi Zhou
    Xinfeng Zhang
    Chengxiao Zhang
    Microchimica Acta, 2014, 181 : 535 - 541
  • [2] Mediatorless amperometric bienzyme glucose biosensor based on horseradish peroxidase and glucose oxidase cross-linked to multiwall carbon nanotubes
    Xu, Shuxia
    Qi, Honglan
    Zhou, Shiyi
    Zhang, Xinfeng
    Zhang, Chengxiao
    MICROCHIMICA ACTA, 2014, 181 (5-6) : 535 - 541
  • [3] A Glucose Biosensor based on Horseradish Peroxidase and Glucose Oxidase Co-entrapped in Carbon Nanotubes Modified Electrode
    Yang, Han
    Gong, Coucong
    Miao, Longfei
    Xu, Fugang
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (06): : 4958 - 4969
  • [4] Carbon felt-based reagentless amperometric hydrogen peroxide biosensor using co-immobilized toluidine blue O and horseradish peroxidase
    Hasebe, Y
    Murao, R
    Uchiyama, S
    ELECTROCHEMISTRY, 2000, 68 (11) : 904 - 906
  • [5] A Mediator-Free Bienzyme Amperometric Biosensor Based on Horseradish Peroxidase and Glucose Oxidase Immobilized on Carbon Nanotube Modified Electrode
    Yao, Yan-Li
    Shiu, Kwok-Keung
    ELECTROANALYSIS, 2008, 20 (19) : 2090 - 2095
  • [6] Glucose oxidase-modified carbon-felt-reactor coupled with peroxidase-modified carbon-felt-detector for amperometric flow determination of glucose
    Wang, Yue
    Hasebe, Yasushi
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2012, 32 (03): : 432 - 439
  • [7] Carbon felt-based bioelectrocatalytic flow detectors: Highly sensitive amperometric determination of hydrogen peroxide using adsorbed peroxidase and thionine
    Hasebe, Yasushi
    Imai, Ryosuke
    Hirono, Masaki
    Uchiyama, Shunichi
    ANALYTICAL SCIENCES, 2007, 23 (01) : 71 - 74
  • [8] A glucose oxidase Co(II) phthalocyanine carbon paste biosensor for the amperometric detection of glucose
    Turdean, G
    Popescu, IC
    Oniciu, L
    REVUE ROUMAINE DE CHIMIE, 1998, 43 (03) : 203 - 208
  • [9] Chemiluminescence flow biosensor for glucose based on gold nano particle-enhanced activities of glucose oxidase and horseradish peroxidase
    Lan, Dan
    Li, Baoxin
    Zhang, Zhujun
    BIOSENSORS & BIOELECTRONICS, 2008, 24 (04): : 934 - 938
  • [10] Carbon Felt-based Bioelectrocatalytic Flow Detectors: Highly Sensitive Amperometric Determination of Hydrogen Peroxide Using Adsorbed Peroxidase and Thionine
    Yasushi Hasebe
    Ryosuke Imai
    Masaki Hirono
    Shunichi Uchiyama
    Analytical Sciences, 2007, 23 : 71 - 74