Intraocular lens power calculation: angle κ and ocular biomechanics

被引:3
|
作者
Marques, Joao Heitor [1 ]
Baptista, Pedro Manuel [1 ,2 ]
Ribeiro, Bruno [1 ]
Meneres, Pedro [1 ,2 ]
Beirao, Joao Melo [1 ,2 ]
机构
[1] Ctr Hosp Univ Porto, Serv Oftalmol, Porto, Portugal
[2] Univ Porto, Inst Ciencias Biomed Abel Salazar, Porto, Portugal
来源
关键词
ORBSCAN-II; ACCURACY; ERROR; AGE;
D O I
10.1097/j.jcrs.0000000000001362
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To study the effect of ocular biomechanics on the prediction error of intraocular lens (IOL) power calculation. Setting: Centro Hospitalar Universit & aacute;rio do Porto, Porto, Portugal. Design: Prospective longitudinal study. Methods: This study included 67 subjects. Before cataract surgery subjects underwent biometry with IOLMaster 700 and biomechanical analysis with Corvis Scheimpflug technology. The targeted spherical equivalent was calculated with SRK-T and Barrett Universal II. Associations between prediction error (PE), absolute prediction error (AE), and biometric and biomechanical parameters were performed with stepwise multivariate linear correlation analysis. Results: Using the SRKT formula, there was association between PE and Corvis Biomechanical Index (CBI, B = -0.531, P = .011) and between AE and the horizontal offset between the center of the pupil and the visual axis (angle kappa, B = -0.274, P = .007). Considering the Barret Universal II formula, PE was independently associated with anterior chamber depth (B = -0.279, P = .021) and CBI (B = -0.520, P = .013) and AE was associated with angle kappa (B = -0.370, P = .007). Conclusions: A large angle kappa may reduce the predictability of IOL power calculation. Ocular biomechanics likely influence the refractive outcomes after IOL implantation. This study showed that eyes with softer corneal biomechanics had more myopic PE. This may relate to anteriorization of the effective lens position. Dynamic measurements may be the way to progress into future formulas.
引用
收藏
页码:345 / 351
页数:7
相关论文
共 50 条
  • [41] Accuracy of eight intraocular lens power calculation formulas for segmented multifocal intraocular lens
    Zhao, Jing
    Liu, Liang-Ping
    Cheng, Huan-Huan
    Li, Jian-Bing
    Han, Xiao-Tong
    Liu, Yu
    Wu, Ming-Xing
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2020, 13 (09) : 1378 - 1384
  • [42] Comparison of 9 modern intraocular lens power calculation formulas for a quadrifocal intraocular lens
    Shajari, Mehdi
    Kolb, Carolin M.
    Petermann, Kerstin
    Boehm, Myriam
    Herzog, Michael
    de'Lorenzo, Nina
    Schoenbrunn, Sabrina
    Kohnen, Thomas
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (08): : 942 - 948
  • [43] Accuracy of eight intraocular lens power calculation formulas for segmented multifocal intraocular lens
    Jing Zhao
    Liang-Ping Liu
    Huan-Huan Cheng
    Jian-Bing Li
    Xiao-Tong Han
    Yu Liu
    Ming-Xing Wu
    International Journal of Ophthalmology, 2020, (09) : 1378 - 1384
  • [44] New method to assess the accuracy of intraocular lens power calculation formulas according to ocular biometric parameters
    Fernandez, Joaquin
    Rodriguez-Vallejo, Manuel
    Poyales, Francisco
    Burguera, Noemi
    Garzon, Nuria
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (06): : 849 - 856
  • [45] Intraocular lens power formula based on vergence calculation and lens design
    Naeser, K
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1997, 23 (08): : 1200 - 1207
  • [46] Accuracy of Ten Intraocular Lens Formulas in Spherical Equivalent of Toric Intraocular Lens Power Calculation
    Jingyi Shi
    Zehui Zhu
    Bin Hu
    Shuyi Qian
    Yalan Wang
    Pingjun Chang
    Yun-e Zhao
    Ophthalmology and Therapy, 2024, 13 : 1321 - 1342
  • [47] Shifts in intraocular lens optic configuration may induce errors in intraocular lens power calculation
    Olsen, Thomas
    Melles, Ronald B.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2023, 49 (02): : 215 - 216
  • [48] Accuracy of Ten Intraocular Lens Formulas in Spherical Equivalent of Toric Intraocular Lens Power Calculation
    Shi, Jingyi
    Zhu, Zehui
    Hu, Bin
    Qian, Shuyi
    Wang, Yalan
    Chang, Pingjun
    Zhao, Yun-e
    OPHTHALMOLOGY AND THERAPY, 2024, 13 (05) : 1321 - 1342
  • [49] MATRIX FORMULA FOR INTRAOCULAR-LENS POWER CALCULATION
    COLLIAC, JP
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1990, 31 (02) : 374 - 381
  • [50] Pterygium size and effect on intraocular lens power calculation
    Koc, Mustafa
    Uzel, Mehmet Murat
    Aydemir, Emre
    Yavrum, Fuat
    Kosekahya, Pinar
    Yilmazbas, Pelin
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (11): : 1620 - 1625