Intraocular lens power calculation: angle κ and ocular biomechanics

被引:3
|
作者
Marques, Joao Heitor [1 ]
Baptista, Pedro Manuel [1 ,2 ]
Ribeiro, Bruno [1 ]
Meneres, Pedro [1 ,2 ]
Beirao, Joao Melo [1 ,2 ]
机构
[1] Ctr Hosp Univ Porto, Serv Oftalmol, Porto, Portugal
[2] Univ Porto, Inst Ciencias Biomed Abel Salazar, Porto, Portugal
来源
关键词
ORBSCAN-II; ACCURACY; ERROR; AGE;
D O I
10.1097/j.jcrs.0000000000001362
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To study the effect of ocular biomechanics on the prediction error of intraocular lens (IOL) power calculation. Setting: Centro Hospitalar Universit & aacute;rio do Porto, Porto, Portugal. Design: Prospective longitudinal study. Methods: This study included 67 subjects. Before cataract surgery subjects underwent biometry with IOLMaster 700 and biomechanical analysis with Corvis Scheimpflug technology. The targeted spherical equivalent was calculated with SRK-T and Barrett Universal II. Associations between prediction error (PE), absolute prediction error (AE), and biometric and biomechanical parameters were performed with stepwise multivariate linear correlation analysis. Results: Using the SRKT formula, there was association between PE and Corvis Biomechanical Index (CBI, B = -0.531, P = .011) and between AE and the horizontal offset between the center of the pupil and the visual axis (angle kappa, B = -0.274, P = .007). Considering the Barret Universal II formula, PE was independently associated with anterior chamber depth (B = -0.279, P = .021) and CBI (B = -0.520, P = .013) and AE was associated with angle kappa (B = -0.370, P = .007). Conclusions: A large angle kappa may reduce the predictability of IOL power calculation. Ocular biomechanics likely influence the refractive outcomes after IOL implantation. This study showed that eyes with softer corneal biomechanics had more myopic PE. This may relate to anteriorization of the effective lens position. Dynamic measurements may be the way to progress into future formulas.
引用
收藏
页码:345 / 351
页数:7
相关论文
共 50 条
  • [21] The SRKII formula in the calculation of intraocular lens power
    Nurözler, A
    Ünlü, N
    Yalvaç, IS
    Kasim, R
    Duman, S
    OPHTHALMOLOGICA, 1998, 212 (03) : 153 - 156
  • [22] Intraocular lens power calculation in eyes with keratoconus
    Garzon, Nuria
    Arriola-Villalobos, Pedro
    Felipe, Gema
    Poyales, Francisco
    Garcia-Montero, Maria
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (05): : 778 - 783
  • [23] Advancements in intraocular lens power calculation formulas
    Chung, Jinkwon
    Bu, Jennifer J.
    Afshari, Natalie A.
    CURRENT OPINION IN OPHTHALMOLOGY, 2022, 33 (01) : 35 - 40
  • [24] Ptosis effects on intraocular lens power calculation
    Aydemir, Emre
    Aydemir, Gozde Aksoy
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2023, 49 (02): : 171 - 176
  • [25] Intraoperative Aberrometry and Intraocular Lens Power Calculation
    Galvis, Virgilio
    Tello, Alejandro
    Sacoto, Jose I.
    JOURNAL OF REFRACTIVE SURGERY, 2016, 32 (02) : 138 - 138
  • [26] Sources of error in intraocular lens power calculation
    Norrby, Sverker
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (03): : 368 - 376
  • [27] Intraocular lens power calculation in short eyes
    Gavin, E. A.
    Hammond, C. J.
    EYE, 2008, 22 (07) : 935 - 938
  • [28] Intraocular lens power calculation for the equine eye
    Meister, Ulrike
    Gorig, Christiane
    Murphy, Christopher J.
    Haan, Hubertus
    Ohnesorge, Bernhard
    Boeve, Michael H.
    BMC VETERINARY RESEARCH, 2018, 14
  • [29] Intraocular Lens Power Calculation: A Challenging Case
    Rosa, Nicola
    De Bernardo, Maddalena
    Iaccarino, Stefania
    Cennamo, Michela
    OPTOMETRY AND VISION SCIENCE, 2014, 91 (02) : E29 - E31
  • [30] Intraocular lens power calculation in short eyes
    E A Gavin
    C J Hammond
    Eye, 2008, 22 : 935 - 938