Processing calibration data of low-temperature thermometer based on clustering algorithm

被引:0
|
作者
Liao, Yi [1 ]
Zhang, Yu [2 ,3 ]
Zha, Kuifan [2 ]
Liu, Xuming [2 ,3 ]
Pan, Changzhao [2 ,3 ]
机构
[1] Southern Univ Sci & Technol, Dept Phys, Shenzhen 518055, Peoples R China
[2] Int Quantum Acad, Shenzhen 518048, Peoples R China
[3] Southern Univ Sci & Technol, Shenzhen Inst Quantum Sci & Engn, Shenzhen 518055, Peoples R China
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2024年 / 95卷 / 08期
基金
国家重点研发计划;
关键词
Data curation - Gluing - Network security;
D O I
10.1063/5.0216712
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The scarcity of cryogenic thermometers often stems from their high cost and lengthy lead times for calibration. Establishing an in-lab temperature calibration system is necessary to quickly make use of uncalibrated sensors or self-made sensors. This paper introduces a straightforward and high-accuracy thermometer calibration system. By employing copper screws as thermal links between the sensor platform and the cryogen-free refrigerator, temperature oscillation on the sensor platform is suppressed to a few millikelvins. In addition, this paper presents a data processing model based on clustering algorithms. These algorithms sort and group data based on distance, which is similar to human visual judgment of data. This paper discusses the parameter optimization process of the clustering algorithm to interpret the automated data process. The cryogenic temperature sensors calibrated by this system exhibited high accuracy, with relative errors of less than 1% compared to standard thermometers. Moreover, automatically processing calibration data from two uncalibrated thermometers takes just over 10 min, highlighting the effectiveness of this calibration system.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] THERMOMETER EQUATIONS FOR LOW-TEMPERATURE GLASS - CERAMIC CAPACITANCE THERMOMETERS
    LAWLESS, WN
    PANCHYK, EA
    CRYOGENICS, 1972, 12 (03) : 196 - &
  • [32] A SILICON ON SAPPHIRE THERMOMETER FOR SMALL SAMPLE LOW-TEMPERATURE CALORIMETRY
    EARLY, SR
    HELLMAN, F
    MARSHALL, J
    GEBALLE, TH
    PHYSICA B & C, 1981, 107 (1-3): : 327 - 328
  • [33] PLATINUM-COBALT RESISTANCE THERMOMETER FOR LOW-TEMPERATURE USE
    SHIRATORI, T
    MITSUI, K
    JAPANESE JOURNAL OF APPLIED PHYSICS, 1978, 17 (07) : 1289 - 1290
  • [34] STUDY OF THE INTERPOLATION CHARACTERISTICS OF A SEALED LOW-TEMPERATURE GAS THERMOMETER
    NARA, K
    RUSBY, RL
    HEAD, DI
    CRYOGENICS, 1990, 30 (11) : 952 - 958
  • [35] Self-Calibrating Infrared Thermometer for Low-Temperature Measurement
    Barry, Tim
    Fuller, Gary
    Hayatleh, Khaled
    Lidgey, John
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2011, 60 (06) : 2047 - 2052
  • [36] Low-temperature thermometer using sputtered ZrNx thin film
    Yotsuya, T
    Yoshitake, M
    Kodama, T
    CRYOGENICS, 1997, 37 (12) : 817 - 822
  • [37] Miniature high-resolution thermometer for low-temperature applications
    Welander, PB
    Hahn, I
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (09): : 3600 - 3604
  • [38] THERMAL ANCHORING AND CALIBRATION OF LOW-TEMPERATURE SENSORS
    KOEPPE, W
    KERNTECHNIK, 1973, 15 (08) : 353 - 357
  • [39] Low-temperature blackbodies and facility for calibration of them
    Morozova, SP
    Morozov, PA
    Sapritsky, VI
    Lisiansky, BE
    Dovgilov, NL
    Liang, YX
    Li, YM
    Yue, WL
    OPTICAL DESIGN AND TESTING, 2002, 4927 : 118 - 124
  • [40] Intelligent Analysis and Processing Technology of Big Data Based on Clustering Algorithm
    Zheng, Zheng
    Cao, Fukai
    Gao, Song
    Sharma, Amit
    INFORMATICA-AN INTERNATIONAL JOURNAL OF COMPUTING AND INFORMATICS, 2022, 46 (03): : 393 - 402