A Linearized Temperature Measurement System Based on the B-Mode of SC-Cut Quartz Crystal

被引:0
|
作者
Li, Zhiqi [1 ]
Zhai, Haipeng [1 ]
Miao, Miao [1 ]
Zhou, Wei [1 ]
机构
[1] Xidian Univ, Sch Mechanoelect Engn, Xian 710071, Peoples R China
基金
中国国家自然科学基金;
关键词
B-mode; digitizer; linearization; SC-cut quartz crystal; temperature measurement;
D O I
10.1109/JSEN.2024.3374763
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This article demonstrates a linearized temperature measurement system based on the B-mode of SC-cut quartz crystal, which has high precision and good linearity. The proposed system uses a digital linear phase comparison measurement method by selecting a phase detection region, which achieves high resolution and fast response for temperature measurement. Extensive error analysis and performance evaluation of the system were conducted in this study. The developed linearized temperature measurement system demonstrated excellent performance, including a wide temperature measuring range from (-10 C-degrees to 80 C-degrees), providing sufficient resolution and extremely fast response time with a resolution of 0.01 C-degrees at 10 mu s, a resolution of 5E-5 C-degrees at 10 ms, and a resolution of 1E-7 C-degrees at 1 s when the temperature keeps stable. It achieves an extremely low-temperature measurement relative error (R.E. < 0.24%) and nonlinearity (N.L. < 0.18%). The measurement results show that the maximum estimate of the Allan variance is 2.3E-4 C-degrees. The proposed system has wide prospects for intelligent applications and can play a crucial role in scenarios that require high-precision and fast-response temperature measurements.
引用
收藏
页码:12251 / 12258
页数:8
相关论文
共 50 条
  • [31] Design, Analysis, and Hardware Verification of a Linearized Thermistor-Based Temperature Measurement System
    Elangovan, K.
    Sontakke, British Ashok
    Sreekantan, Anoop Chandrika
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71
  • [32] A novel Love-mode device based on a ZnO/ST-cut quartz crystal structure for sensing applications
    Zadeh, KK
    Trinchi, A
    Wlodarski, W
    Holland, A
    SENSORS AND ACTUATORS A-PHYSICAL, 2002, 100 (2-3) : 135 - 143
  • [33] Third overtone frequency turn-over temperature characteristics vs orientations for quartz resonators vibrating in thickness-shear B-mode
    Nakazawa, M
    Yamazaki, H
    Takeuchi, M
    PROCEEDINGS OF THE 1997 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM, 1997, : 715 - 721
  • [34] Full-Reference Image Quality Assessment-Based B-Mode Ultrasound Image Similarity Measurement
    Xu, Kele
    Gao, Zhifeng
    Cai, Hengxing
    MEDICAL PHYSICS, 2017, 44 (06)
  • [35] Neural Network Ensemble Based CAD System for Focal Liver Lesions from B-Mode Ultrasound
    Jitendra Virmani
    Vinod Kumar
    Naveen Kalra
    Niranjan Khandelwal
    Journal of Digital Imaging, 2014, 27 : 520 - 537
  • [36] Neural Network Ensemble Based CAD System for Focal Liver Lesions from B-Mode Ultrasound
    Virmani, Jitendra
    Kumar, Vinod
    Kalra, Naveen
    Khandelwal, Niranjan
    JOURNAL OF DIGITAL IMAGING, 2014, 27 (04) : 520 - 537
  • [37] Automatic System Identification of Tissue Abnormalities Based on 2D B-Mode Ultrasound Images
    Diaz-Suarez, Victor D.
    Travieso, Carlos M.
    Gonzalez-Fernandez, Javier
    Ferrer, Miguel A.
    Gomez, Luis
    Alonso, Jesus B.
    COMPUTER AIDED SYSTEMS THEORY - EUROCAST 2009, 2009, 5717 : 137 - +
  • [38] PRECISE DETERMINATION OF THE OPTIMUM SUPPORTING POSITION OF A STRESS COMPENSATED (SC) CUT QUARTZ-CRYSTAL RESONATOR USING A SEMICONDUCTOR PULSED-LASER SYSTEM
    WATANABE, Y
    KOYAMA, M
    SEKIMOTO, H
    OOMURA, Y
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1995, 34 (5B): : 2617 - 2619
  • [39] A Data-Driven Approach for Estimating Temperature Variations Based on B-mode Ultrasound Images and Changes in Backscattered Energy
    Oliveira, Luiz F. R.
    Franca, Felipe M. G.
    Pereira, Wagner C. A.
    ULTRASONIC IMAGING, 2024, 46 (01) : 3 - 16
  • [40] PCA-SVM based CAD System for Focal Liver Lesions using B-Mode Ultrasound Images
    Virmani, Jitendra
    Kumar, Vinod
    Kalra, Naveen
    Khandelwal, Niranjan
    DEFENCE SCIENCE JOURNAL, 2013, 63 (05) : 478 - 486