A Linearized Temperature Measurement System Based on the B-Mode of SC-Cut Quartz Crystal

被引:0
|
作者
Li, Zhiqi [1 ]
Zhai, Haipeng [1 ]
Miao, Miao [1 ]
Zhou, Wei [1 ]
机构
[1] Xidian Univ, Sch Mechanoelect Engn, Xian 710071, Peoples R China
基金
中国国家自然科学基金;
关键词
B-mode; digitizer; linearization; SC-cut quartz crystal; temperature measurement;
D O I
10.1109/JSEN.2024.3374763
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This article demonstrates a linearized temperature measurement system based on the B-mode of SC-cut quartz crystal, which has high precision and good linearity. The proposed system uses a digital linear phase comparison measurement method by selecting a phase detection region, which achieves high resolution and fast response for temperature measurement. Extensive error analysis and performance evaluation of the system were conducted in this study. The developed linearized temperature measurement system demonstrated excellent performance, including a wide temperature measuring range from (-10 C-degrees to 80 C-degrees), providing sufficient resolution and extremely fast response time with a resolution of 0.01 C-degrees at 10 mu s, a resolution of 5E-5 C-degrees at 10 ms, and a resolution of 1E-7 C-degrees at 1 s when the temperature keeps stable. It achieves an extremely low-temperature measurement relative error (R.E. < 0.24%) and nonlinearity (N.L. < 0.18%). The measurement results show that the maximum estimate of the Allan variance is 2.3E-4 C-degrees. The proposed system has wide prospects for intelligent applications and can play a crucial role in scenarios that require high-precision and fast-response temperature measurements.
引用
收藏
页码:12251 / 12258
页数:8
相关论文
共 50 条
  • [21] In Vivo Noninvasive Temperature Measurement by B-Mode Ultrasound Imaging
    Pouch, Alison M.
    Cary, Theodore W.
    Schultz, Susan M.
    Sehgal, Chandra M.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2010, 29 (11) : 1595 - 1606
  • [22] The measurement of low sediment concentration based on B-mode ultrasound images
    Ma, Zhimin
    Zou, Xianjian
    Zhao, Xiaohong
    Hu, Xiangyang
    Yingyong Jichu yu Gongcheng Kexue Xuebao/Journal of Basic Science and Engineering, 2013, 21 (04): : 796 - 803
  • [23] Third-order mindlin plate theory predictions for the frequency-temperature behavior of straight crested wave modes in AT- and SC-Cut quartz plates
    Yong, YK
    PROCEEDINGS OF THE 1996 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM (50TH ANNIVERSARY), 1996, : 648 - 656
  • [24] SVM-Based CAC System for B-Mode Kidney Ultrasound Images
    M. B. Subramanya
    Vinod Kumar
    Shaktidev Mukherjee
    Manju Saini
    Journal of Digital Imaging, 2015, 28 : 448 - 458
  • [25] SVM-Based CAC System for B-Mode Kidney Ultrasound Images
    Subramanya, M. B.
    Kumar, Vinod
    Mukherjee, Shaktidev
    Saini, Manju
    JOURNAL OF DIGITAL IMAGING, 2015, 28 (04) : 448 - 458
  • [26] Dual-mode AT-cut quartz resonant pressure sensor for wide pressure and temperature measurement ranges
    Zhang, Wenjun
    Xu, Yanbo
    Zhang, Zengxing
    Jing, Junmin
    Yao, Bin
    Gao, Libo
    Xue, Chenyang
    Tian, Zhongqun
    SENSORS AND ACTUATORS A-PHYSICAL, 2025, 382
  • [27] A system for real-time measurement of the brachial artery diameter in B-mode ultrasound images
    Gemignani, Vincenzo
    Faita, Francesco
    Ghiadoni, Lorenzo
    Poggianti, Elisa
    Demi, Marcello
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2007, 26 (03) : 393 - 404
  • [28] Deep Learning-Based Measurement of Total Plaque Area in B-Mode Ultrasound Images
    Zhou, Ran
    Guo, Fumin
    Azarpazhooh, M. Reza
    Hashemi, Samineh
    Cheng, Xinyao
    Spence, J. David
    Ding, Mingyue
    Fenster, Aaron
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2021, 25 (08) : 2967 - 2977
  • [29] Photoacoustic tomography imaging system based on digital B-mode ultrasound diagnosis equipment
    Guo, Hua
    Yang, Sihua
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2009, 80 (01):
  • [30] System for Estimating Sclerosis of in vivo Arteries Based on Ultrasound B-mode Image Analysis
    Nogata, Fumio
    Yokota, Yasunari
    Kawamura, Yoko
    Walsh, W. R.
    2008 10TH INTERNATIONAL CONFERENCE ON CONTROL AUTOMATION ROBOTICS & VISION: ICARV 2008, VOLS 1-4, 2008, : 1779 - +