A feasibility study to predict 3D dose delivery accuracy for IMRT using DenseNet with log files

被引:0
|
作者
Huang, Ying [1 ,2 ,3 ]
Cai, Ruxin [3 ]
Pi, Yifei [4 ]
Ma, Kui [5 ]
Kong, Qing [1 ]
Zhuo, Weihai [2 ]
Kong, Yan [6 ]
机构
[1] Fudan Univ, Inst Modern Phys, Shanghai, Peoples R China
[2] Fudan Univ, Inst Radiat Med, Shanghai 200032, Peoples R China
[3] Shanghai Jiao Tong Univ, Shanghai Chest Hosp, Sch Med, Shanghai, Peoples R China
[4] hengzhou Univ, Affiliated Hosp 1, Dept Radiat Oncol, Zhengzhou, Henan, Peoples R China
[5] Varian Med Syst, Beijing, Peoples R China
[6] Jiangnan Univ, Dept Radiat Oncol, Affiliated Hosp, Wuxi 214122, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Three-dimensional gamma prediction; log files; patient-specific quality assurance; MLC POSITIONAL ERRORS; CLINICAL IMPLEMENTATION; QUALITY-ASSURANCE; SLIDING WINDOW; RADIOTHERAPY; VERIFICATION; EXPERIENCE;
D O I
10.3233/XST-230412
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
OBJECTIVE: This study aims to explore the feasibility of DenseNet in the establishment of a three-dimensional (3D) gamma prediction model of IMRT based on the actual parameters recorded in the log files during delivery. METHODS: A total of 55 IMRT plans (including 367 fields) were randomly selected. The gamma analysis was performed using gamma criteria of 3% /3 mm (Dose Difference/Distance to Agreement), 3% /2 mm, 2% /3 mm, and 2% /2 mm with a 10% dose threshold. In addition, the log files that recorded the gantry angle, monitor units (MU), multi-leaf collimator (MLC), and jaws position during delivery were collected. These log files were then converted to MU-weighted fluence maps as the input of DenseNet, gamma passing rates (GPRs) under four different gamma criteria as the output, and mean square errors (MSEs) as the loss function of this model. RESULTS: Under different gamma criteria, the accuracy of a 3D GPR prediction model decreased with the implementation of stricter gamma criteria. In the test set, the mean absolute error (MAE) of the prediction model under the gamma criteria of 3% /3 mm, 2% /3 mm, 3% /2 mm, and 2% /2 mm was 1.41, 1.44, 3.29, and 3.54, respectively; the root mean square error (RMSE) was 1.91, 1.85, 4.27, and 4.40, respectively; the Sr was 0.487, 0.554, 0.573, and 0.506, respectively. There was a correlation between predicted and measured GPRs (P < 0.01). Additionally, there was no significant difference in the accuracy between the validation set and the test set. The accuracy in the high GPR group was high, and the MAE in the high GPR group was smaller than that in the low GPR group under four different gamma criteria. CONCLUSIONS: In this study, a 3D GPR prediction model of patient-specific QA using DenseNet was established based on log files. As an auxiliary tool for 3D dose verification in IMRT, this model is expected to improve the accuracy and efficiency of dose validation.
引用
收藏
页码:1199 / 1208
页数:10
相关论文
共 50 条
  • [21] 3D DOSE DISTRIBUTION FOR GYN WITH DOSE ACCUMULATION BETWEEN INSERTIONS: FEASIBILITY STUDY.
    Reniers, B.
    Janssens, G.
    Verhaegen, F.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S102 - S102
  • [22] RapidArc patient specific mechanical delivery accuracy under extreme mechanical limits using linac log files
    Wijesooriya, Krishni
    Aliotta, Eric
    Benedict, Stanley
    Read, Paul
    Rich, Tyvin
    Larner, James
    MEDICAL PHYSICS, 2012, 39 (04) : 1846 - 1853
  • [23] In Vivo 3D Dose Verification for IMRT Using Electronic Portal Imaging Device (EPID)
    Chang, C.
    Anderson, N. G.
    Zhu, T. C.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [24] Iterative neuronavigation using 3D ultrasound - a feasibility study
    Lindner, D
    Trantakis, C
    Schmidtgen, A
    Grunst, G
    Arnold, S
    Meixensberger, E
    CARS 2003: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2003, 1256 : 619 - 624
  • [25] THE 3D QUANTIFICATION OF DELIVERED IMRT DOSE DISTRIBUTIONS FOR MOBILE TARGETS
    Hoffe, S.
    Opp, D.
    Latifi, K.
    Pritz, J.
    Shridhar, R.
    Dilling, T.
    Zhang, G.
    Feygelman, V.
    Forster, K.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S371 - S371
  • [26] DOSE DELIVERY VERIFICATION USING 3D DOSE RECONSTRUCTION IN STEREOTACTIC BODY RADIOTHERAPY FOR NSCLC
    van Elmpt, W.
    Petit, S.
    Nijsten, S.
    Lambin, P.
    Dekker, A.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S95 - S96
  • [27] STUDY OF THE 3D SCANNING ACCURACY USING INDUSTRIAL ROBOT
    Panasiuk, J.
    Kaczmarek, W.
    Besseghieur, K.
    Borys, Sz.
    Siwek, M.
    Golawski, K.
    ENGINEERING MECHANICS 2018 PROCEEDINGS, VOL 24, 2018, : 641 - 644
  • [28] Feasibility of 3D Printed Patient Specific Phantoms for IMRT/IGRT QA
    Ehler, E.
    Higgins, P.
    Dusenbery, K.
    MEDICAL PHYSICS, 2014, 41 (06) : 392 - 393
  • [29] 3D dose delivery QA using couch and gantry mounted cameras
    Ashraf, M. Ramish
    Farwell, Cedar
    Alexander, Daniel A.
    Zhang, Rongxiao
    Gladstone, David J.
    Pogue, Brian W.
    Bruza, Petr
    11TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY, IC3DDOSE, 2022, 2167
  • [30] Quantifying the performance of two different types of commercial software programs for 3D patient dose reconstruction for prostate cancer patients: Machine log files vs. machine log files with EPID images
    Kadoya, Noriyuki
    Kon, Yoshio
    Takayama, Yoshiki
    Matsumoto, Takuya
    Hayashi, Naoki
    Katsuta, Yoshiyuki
    Ito, Kengo
    Chiba, Takahito
    Dobashi, Suguru
    Takeda, Ken
    Jingu, Keiichi
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 45 : 170 - 176