3D dose delivery QA using couch and gantry mounted cameras

被引:1
|
作者
Ashraf, M. Ramish [1 ]
Farwell, Cedar [2 ]
Alexander, Daniel A. [1 ]
Zhang, Rongxiao [1 ,3 ,4 ]
Gladstone, David J. [1 ,3 ,4 ]
Pogue, Brian W. [1 ,2 ,4 ]
Bruza, Petr [1 ,2 ]
机构
[1] Dartmouth Coll, Thayer Sch Engn, Hanover, NH 03755 USA
[2] DoseOptics, Lebanon, NH 03756 USA
[3] Dartmouth Coll, Geisel Sch Med, Dept Med, Hanover, NH 03755 USA
[4] Dartmouth Hitchcock Med Ctr, Norris Cotton Canc Ctr, Lebanon, NH 03756 USA
关键词
DOSIMETRY;
D O I
10.1088/1742-6596/2167/1/012027
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
While 2D planar radiation therapy quality assurance techniques suffice for linac verification, a full 3D dosimetry measurement is ideal for robust treatment plan verification. In this study, an optical 3D dose reconstruction technique based on radioluminescence imaging is presented, using two orthogonal views provided by gantry and couch mounted cameras. Both small field and multi-target beam apertures were tested, mimicking typical 3D radiosurgery plans. Pass rates >94% for 3D gamma with 2%/2mm were achieved in all cases. Slice images were used for gamma analysis in each of transverse, sagittal and coronal planes, through the point of maximum dose. This proposed system can enable real-time imaging of beam delivery dynamics in a cylindrical water-equivalent phantom with high spatial resolution 3D reconstruction of the dose distribution, and verification of each beamlet used.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Real Time Plan Verification of Radiotherapy Treatment Plans Using Couch and Gantry Mounted Cameras
    Ashraf, M.
    Bruza, P.
    Pogue, B.
    Gladstone, D.
    Williams, B.
    MEDICAL PHYSICS, 2020, 47 (06) : E474 - E475
  • [2] Couch and Gantry Rotation Isocenter QA Using Portal Imager
    Pennell, R.
    Jozsef, G.
    DeWyngaert, K.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [3] A 3D star shot to determine the gantry, collimator, and couch axes positions
    Corns, Robert
    Yang, Kaida
    Ross, Mason
    Bhandari, Shiva
    Aryal, Makunda
    Ciaccio, Peter
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (07):
  • [4] The Effects of Low Dose Regions On 3D IMRT QA Delivery Using a MatriXX 2D Array and MULTICUBE
    Fox, C.
    Sanford, R.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [5] A Method of 3D Dose Reconstruction Using MapCHECK Measurement for IMRT QA
    Kim, S.
    Barnett, E.
    Gallamore, M.
    Yeung, I.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [6] Using drone-mounted cameras for on-site body documentation: 3D mapping and active survey
    Urbanova, Petra
    Jurda, Mikolas
    Vojtisek, Tomas
    Krajsa, Jan
    FORENSIC SCIENCE INTERNATIONAL, 2017, 281 : 52 - 62
  • [7] Evaluation of IMRT QA Using 3DVH, a 3D Patient Dose and Verification Analysis Software
    Jarry, G.
    Martin, D.
    Lemire, M.
    Ayles, M.
    Pater, P.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [8] 3D gait recognition using multiple cameras
    Zhao, Guoying
    Liu, Guoyi
    Li, Hua
    Pietikainen, Matti
    PROCEEDINGS OF THE SEVENTH INTERNATIONAL CONFERENCE ON AUTOMATIC FACE AND GESTURE RECOGNITION - PROCEEDINGS OF THE SEVENTH INTERNATIONAL CONFERENCE, 2006, : 529 - +
  • [9] Survey of 3D modeling using depth cameras
    Xu H.
    Xu J.
    Xu W.
    Virtual Reality and Intelligent Hardware, 2019, 1 (05): : 483 - 499
  • [10] 3D surveillance system using multiple cameras
    Mishra, Ajay Kumar
    Ni, Bingbing
    Winkler, Stefan
    Kassim, Ashraf
    VIDEOMETRICS IX, 2007, 6491