Anatomy-based fitting improves speech perception in noise for cochlear implant recipients with single-sided deafness

被引:0
|
作者
Kurz, Anja [1 ]
Herrmann, David [1 ]
Mueller-Graff, Franz-Tassilo [1 ]
Voelker, Johannes [1 ]
Hackenberg, Stephan [1 ]
Rak, Kristen [1 ]
机构
[1] Univ Hosp Wurzburg, Comprehens Hearing Ctr, Dept Oto Rhino Laryngol Head & Neck Surg, Josef Schneider Str 11, D-97080 Wurzburg, Germany
关键词
Cochlear implant in single sided deafness; Anatomy-based fitting; Frequency-to-place mismatch; Speech perception; SPIRAL GANGLION; PITCH;
D O I
10.1007/s00405-024-08984-4
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
ObjectiveTo evaluate objective and subjective hearing outcomes in experienced cochlear implant users with single sided deafness (SSD CI) who used fitting maps created via anatomy-based fitting (ABF) and clinically-based fitting (CBF).ParticipantsTwelve SSD CI users with postlingual hearing loss.InterventionOTOPLAN (Version 3. (MED-EL) was used to determine intracochlear electrode contact positions using post-operative high-resolution flat panel volume computed tomography. From these positions, the corresponding center frequencies and bandwidths were derived for each channel. These were implemented in the clinical fitting software MAESTRO to yield an ABF map individualized to each user.Main Outcome MeasuresABF and CBF maps were compared. Objective speech perception in quiet and in noise, binaural effects, and self-perceived sound quality were evaluated.ResultsSignificantly higher speech perception in noise scores were observed with the ABF map compared to the CBF map (mean SRT50: -6.49 vs. -4.8 dB SNR for the S0NCI configuration and - 3.85 vs. -2.75 dB SNR for the S0N0 configuration). Summation and squelch effects were significantly increased with the ABF map (0.86 vs. 0.21 dB SNR for summation and 0.85 vs. -0.09 dB SNR for squelch). No improvement in speech perception in quiet or spatial release from masking were observed with the ABF map. A similar level of self-perceived sound quality was reported for each map. Upon the end of the study, all users opted to keep the ABF map. This preference was independent of the angular insertion depth of the electrode array.ConclusionsExperienced SSD CI users preferred using the ABF map, which gave them significant improvements in binaural hearing and some aspects of speech perception.
引用
收藏
页码:467 / 479
页数:13
相关论文
共 50 条
  • [41] Audiometric and Patient-Reported Outcomes in Single-Sided Deafness Cochlear Implant Recipients Using the CIQOL-35
    Mitton, Tanner J.
    Yancey, Kristen L.
    Isaacson, Brandon
    Kutz, Walter
    Whitson, Johanna
    Hunter, Jacob B.
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2023, 168 (05) : 1156 - 1163
  • [42] Improving Auditory Perception in Pediatric Single-Sided Deafness: Use of Cochlear Implants? Direct Connection for Remote Speech Perception Rehabilitation
    Agostinelli, Anna
    Pegolo, Margherita
    Montino, Silvia
    Maritan, Francesca
    Gambalonga, Mattia
    Trevisi, Patrizia
    Brotto, Davide
    AMERICAN JOURNAL OF AUDIOLOGY, 2023, 32 (01) : 52 - 58
  • [43] One Click Is Not Enough: Anatomy-Based Fitting in Experienced Cochlear Implant Users
    Kurz, Anja
    Mueller-Graff, Franz-Tassilo
    Hagen, Rudolf
    Rak, Kristen
    OTOLOGY & NEUROTOLOGY, 2022, 43 (10) : 1176 - 1180
  • [44] Cochlear Implant Use Remains Consistent Over Time in Children With Single-Sided Deafness
    Ganek, Hillary V.
    Cushing, Sharon L.
    Papsin, Blake C.
    Gordon, Karen A.
    EAR AND HEARING, 2020, 41 (03): : 678 - 685
  • [45] Influence of listening environment on usage patterns in cochlear implant patients with single-sided deafness
    Garcia, Alejandro
    Haleem, Afash
    Chari, Divya A.
    Morse-Fortier, Charlotte
    Arenberg, Julie G.
    Lee, Daniel J.
    COCHLEAR IMPLANTS INTERNATIONAL, 2023, 24 (06) : 335 - 341
  • [46] Correction to: The impact of cochlear implant microphone settings on the binaural hearing of experienced cochlear implant users with single-sided deafness
    Anja Kurz
    Maren Zanzinger
    Rudolf Hagen
    Kristen Rak
    European Archives of Oto-Rhino-Laryngology, 2021, 278 : 2079 - 2079
  • [47] Long-Term Improvement in Localization for Cochlear Implant Users with Single-Sided Deafness
    Thompson, Nicholas J.
    Dillon, Margaret T.
    Buss, Emily
    Rooth, Meredith A.
    Richter, Margaret E.
    Pillsbury, Harold C.
    Brown, Kevin D.
    LARYNGOSCOPE, 2022, 132 (12): : 2453 - 2458
  • [48] Pediatric Single-Sided Deafness: A Review of Prevalence, Radiologic Findings, and Cochlear Implant Candidacy
    Dewyer, Nicholas A.
    Smith, Sullivan
    Herrmann, Barbara
    Reinshagen, Katherine L.
    Lee, Daniel J.
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2022, 131 (03): : 233 - 238
  • [49] Differences in music appreciation between bilateral and single-sided cochlear implant recipients
    Yang, Alex W.
    Pillion, Elicia M.
    Riley, Charles A.
    Tolisano, Anthony M.
    AMERICAN JOURNAL OF OTOLARYNGOLOGY, 2024, 45 (04)
  • [50] Duration of unilateral auditory deprivation is associated with reduced speech perception after cochlear implantation: A single-sided deafness study
    Cohen, Samuel M.
    Svirsky, Mario A.
    COCHLEAR IMPLANTS INTERNATIONAL, 2019, 20 (02) : 51 - 56