Anatomy-based fitting improves speech perception in noise for cochlear implant recipients with single-sided deafness

被引:0
|
作者
Kurz, Anja [1 ]
Herrmann, David [1 ]
Mueller-Graff, Franz-Tassilo [1 ]
Voelker, Johannes [1 ]
Hackenberg, Stephan [1 ]
Rak, Kristen [1 ]
机构
[1] Univ Hosp Wurzburg, Comprehens Hearing Ctr, Dept Oto Rhino Laryngol Head & Neck Surg, Josef Schneider Str 11, D-97080 Wurzburg, Germany
关键词
Cochlear implant in single sided deafness; Anatomy-based fitting; Frequency-to-place mismatch; Speech perception; SPIRAL GANGLION; PITCH;
D O I
10.1007/s00405-024-08984-4
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
ObjectiveTo evaluate objective and subjective hearing outcomes in experienced cochlear implant users with single sided deafness (SSD CI) who used fitting maps created via anatomy-based fitting (ABF) and clinically-based fitting (CBF).ParticipantsTwelve SSD CI users with postlingual hearing loss.InterventionOTOPLAN (Version 3. (MED-EL) was used to determine intracochlear electrode contact positions using post-operative high-resolution flat panel volume computed tomography. From these positions, the corresponding center frequencies and bandwidths were derived for each channel. These were implemented in the clinical fitting software MAESTRO to yield an ABF map individualized to each user.Main Outcome MeasuresABF and CBF maps were compared. Objective speech perception in quiet and in noise, binaural effects, and self-perceived sound quality were evaluated.ResultsSignificantly higher speech perception in noise scores were observed with the ABF map compared to the CBF map (mean SRT50: -6.49 vs. -4.8 dB SNR for the S0NCI configuration and - 3.85 vs. -2.75 dB SNR for the S0N0 configuration). Summation and squelch effects were significantly increased with the ABF map (0.86 vs. 0.21 dB SNR for summation and 0.85 vs. -0.09 dB SNR for squelch). No improvement in speech perception in quiet or spatial release from masking were observed with the ABF map. A similar level of self-perceived sound quality was reported for each map. Upon the end of the study, all users opted to keep the ABF map. This preference was independent of the angular insertion depth of the electrode array.ConclusionsExperienced SSD CI users preferred using the ABF map, which gave them significant improvements in binaural hearing and some aspects of speech perception.
引用
收藏
页码:467 / 479
页数:13
相关论文
共 50 条
  • [31] Factors Predictive of Binaural Hearing Restoration by Cochlear Implant in Single-Sided Deafness
    Gersdorff, Guillaume
    Pean, Vincent
    Camby, Severine
    Barriat, Sebastien
    Lefebvre, Philippe P.
    AUDIOLOGY AND NEUROTOLOGY, 2024, 29 (03) : 228 - 238
  • [32] Data Logging Evidence of Cochlear Implant Use in Single-Sided and Bilateral Deafness
    Rauch, Ann-Kathrin
    Kagermann, Stephanie
    Wesarg, Thomas
    Jakob, Till Fabian
    Aschendorff, Antje
    Ihorst, G.
    Speck, Iva
    Arndt, Susan
    AUDIOLOGY AND NEURO-OTOLOGY, 2019, 24 (04) : 206 - 216
  • [33] Auditory Localization Performance in Cochlear Implant Recipients With Single-Sided Deafness: The Challenges and Limitations of Current Outcome Metrics
    Anidi, Chioma
    Abdulrazzak, Obada
    Jones, Gerilyn
    Epperson, Madison V.
    Ibrahim, Nadine I.
    Hartl, Renee M. Banakis
    OTOLOGY & NEUROTOLOGY, 2024, 45 (08) : 878 - 886
  • [34] Cochlear implant treatment of patients with single-sided deafness or asymmetric hearing loss
    Arndt, S.
    Laszig, R.
    Aschendorff, A.
    Hassepass, F.
    Beck, R.
    Wesarg, T.
    HNO, 2017, 65 : 98 - 108
  • [35] Comparison of test methods to assess the implanted ear alone for pediatric cochlear implant recipients with single-sided deafness
    Park, Lisa R.
    Preston, Elizabeth
    Noxon, Amy S.
    Dillon, Margaret T.
    COCHLEAR IMPLANTS INTERNATIONAL, 2021, 22 (05) : 283 - 290
  • [36] The impact of cochlear implant microphone settings on the binaural hearing of experienced cochlear implant users with single-sided deafness
    Kurz, Anja
    Zanzinger, Maren
    Hagen, Rudolf
    Rak, Kristen
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2021, 278 (06) : 2067 - 2077
  • [37] Searching for the Sound of a Cochlear Implant: Evaluation of Different Vocoder Parameters by Cochlear Implant Users With Single-Sided Deafness
    Karoui, Chadlia
    James, Chris
    Barone, Pascal
    Bakhos, David
    Marx, Mathieu
    Macherey, Olivier
    TRENDS IN HEARING, 2019, 23
  • [38] Duration of cochlear implant use in children with prelingual single-sided deafness is a predictor of word perception in the CI ear
    Arras, Tine
    Boudewyns, An
    Dhooge, Ingeborg
    Zarowski, Andrzej
    Philips, Birgit
    Desloovere, Christian
    Wouters, Jan
    van Wieringen, Astrid
    HEARING RESEARCH, 2024, 450
  • [39] Localization and Speech-in-Noise Performance in a Virtual Reality Test Environment: A Pilot Study of Adults With Single-Sided Deafness Using a Cochlear Implant
    Sladen, Douglas P.
    Diedesch, Anna C.
    Zeitler, Daniel M.
    AMERICAN JOURNAL OF AUDIOLOGY, 2024, 33 (03) : 981 - 990
  • [40] Sound Localization and Speech Perception in Noise of Pediatric Cochlear Implant Recipients: Bimodal Fitting Versus Bilateral Cochlear Implants
    Choi, Ji Eun
    Moon, Il Joon
    Kim, Eun Yeon
    Park, Hee-Sung
    Kim, Byung Kil
    Chung, Won-Ho
    Cho, Yang-Sun
    Brown, Carolyn J.
    Hong, Sung Hwa
    EAR AND HEARING, 2017, 38 (04): : 426 - 440