Image Quality and Radiation Exposure in Abdominal Angiography

被引:0
|
作者
Werncke, Thomas [1 ]
Becker, Lena S. [1 ]
Maschke, Sabine K. [1 ]
Hinrichs, Jan B. [2 ]
Meine, Timo C. H. [1 ]
Dewald, Cornelia L. A. [1 ]
Bruesch, Inga [3 ]
Rumpel, Regina [3 ]
Wacker, Frank K. [1 ]
Meyer, Bernhard C. [1 ]
机构
[1] Hannover Med Sch, Dept Diagnost & Intervent Radiol, Carl Neuberg Str 1, D-30625 Hannover, Germany
[2] St Bernward Hosp, Dept Diagnost & Intervent Radiol & Neuroradiol, Hildesheim, Germany
[3] Hannover Med Sch, Inst Lab Anim Sci & Cent Anim Facil, Hannover, Germany
关键词
image quality; interventional radiology; radiation dose; animal study; phantom study; fluoroscopy; AIR GAPS; MANAGEMENT; REDUCTION; SYSTEM;
D O I
10.1097/RLI.0000000000001079
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: This phantom and animal pilot study aimed to compare image quality and radiation exposure between detector-dose-driven exposure control (DEC) and contrast-to-noise ratio (CNR)-driven exposure control (CEC) as functions of source-to-image receptor distance (SID) and collimation. Materials and Methods: First, an iron foil simulated a guide wire in a stack of polymethyl methacrylate and aluminum plates representing patient thicknesses of 15, 25, and 35 cm. Fluoroscopic images were acquired using 5 SIDs ranging from 100 to 130 cm and 2 collimations (full field of view, collimated field of view: 6 x 6 cm). The iron foil CNRs were calculated, and radiation doses in terms of air kerma rate were obtained and assessed using a multivariate regression. Second, 5 angiographic scenarios were created in 2 anesthetized pigs. Fluoroscopic images were acquired at 2 SIDs (110 and 130 cm) and both collimations. Two blinded experienced readers compared image quality to the reference image using full field of view at an SID of 110 cm. Air kerma rate was obtained and compared using t tests. Results: Using DEC, both CNR and air kerma rate increased significantly at longer SID and collimation below the air kerma rate limit. When using CEC, CNR was significantly less dependent of SID, collimation, and patient thickness. Air kerma rate decreased at longer SID and tighter collimation. After reaching the air kerma rate limit, CEC behaved similarly to DEC. In the animal study using DEC, image quality and air kerma rate increased with longer SID and collimation (P < 0.005). Using CEC, image quality was not significantly different than using longer SID or tighter collimation. Air kerma rate was not significantly different at longer SID but lower using collimation (P = 0.012). Conclusions: CEC maintains the image quality with varying SID and collimation stricter than DEC, does not increase the air kerma rate at longer SID and reduces it with tighter collimation. After reaching the air kerma rate limit, CEC and DEC perform similarly.
引用
收藏
页码:711 / 718
页数:8
相关论文
共 50 条
  • [41] Effect of Low-Frame Invasive Coronary Angiography on Radiation and Image Quality
    Ebrahimi, Ramin
    Uberoi, Abhimanyu
    Treadwell, Michelle
    Rafie, Amir H. Sadrzadeh
    AMERICAN JOURNAL OF CARDIOLOGY, 2016, 118 (02): : 195 - 197
  • [42] Image quality evaluation of the angiography imaging system at the European synchrotron radiation facility
    Peterzol, A
    Bravin, A
    Coan, P
    Elleaume, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 510 (1-2): : 45 - 50
  • [43] Image Quality of the Coronary Angiography with Noise Reduction Technology to Decrease the Radiation Dose
    Kumashiro, Masayuki
    Kataoka, Takahiro
    Yokota, Shinobu
    Nakagawa, Shinobu
    Otsuki, Keisuke
    Miyake, Nobuyuki
    Osumi, Shinji
    Yamaoka, Kiyonori
    ACTA MEDICA OKAYAMA, 2018, 72 (02) : 153 - 164
  • [44] Radiation Dose and Image Quality Assessment of the Bolus Timing Method for CT Angiography
    Kim, Myeong Seong
    Lee, Jong-Woong
    Kim, Sun Geun
    Kweon, Dae Cheol
    IRANIAN JOURNAL OF RADIOLOGY, 2017, 14 (02)
  • [45] RADIATION EXPOSURE TO PERSONNEL DURING ANGIOGRAPHY
    GREENE, MW
    EKELUND, MJ
    PITMAN, RJ
    PHYSICS IN MEDICINE AND BIOLOGY, 1977, 22 (03): : 587 - 587
  • [46] RADIATION EXPOSURE AND PROTECTION DURING ANGIOGRAPHY
    BIAZZI, L
    GARBAGNA, P
    ANNALES DE RADIOLOGIE, 1979, 22 (04) : 345 - 347
  • [47] RADIATION EXPOSURE OF OPERATOR DURING ANGIOGRAPHY
    LACKNER, K
    EWEN, K
    FELIX, R
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1978, 128 (01): : 86 - 90
  • [48] Evaluating Image Quality and Radiation Dose in Low-Dose Thoraco-Abdominal CT Angiography with a Tin Filter for Patients with Aortic Disease
    Oh, Chang Hoon
    Cho, Soo Buem
    Kwon, Hyeyoung
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (04)
  • [49] Image Quality and Radiation Dose Optimization for High-Resolution Pulmonary CT Angiography Using 100 kVp and Automatic Exposure Control
    Alrajhi, S.
    Alhumayyd, S.
    Blobel, J.
    Kashani, H.
    Odedra, D.
    Roberts, H.
    Narinder, P.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (05)
  • [50] Optimal electrocardiographic pulsing windows and heart rate: Effect on image quality and radiation exposure at dual-source coronary CT angiography
    Weustink, Annick C.
    Mollet, Nico R.
    Pugliese, Francesca
    Meijboom, Willem B.
    Nieman, Koen
    Heijenbrok-Kal, Majanka H.
    Flohr, Thomas G.
    Neefjes, Lisanne A. E.
    Cademartiri, Filippo
    de Feyter, Pim J.
    Krestin, Gabriel P.
    RADIOLOGY, 2008, 248 (03) : 792 - 798