Image Quality and Radiation Exposure in Abdominal Angiography

被引:0
|
作者
Werncke, Thomas [1 ]
Becker, Lena S. [1 ]
Maschke, Sabine K. [1 ]
Hinrichs, Jan B. [2 ]
Meine, Timo C. H. [1 ]
Dewald, Cornelia L. A. [1 ]
Bruesch, Inga [3 ]
Rumpel, Regina [3 ]
Wacker, Frank K. [1 ]
Meyer, Bernhard C. [1 ]
机构
[1] Hannover Med Sch, Dept Diagnost & Intervent Radiol, Carl Neuberg Str 1, D-30625 Hannover, Germany
[2] St Bernward Hosp, Dept Diagnost & Intervent Radiol & Neuroradiol, Hildesheim, Germany
[3] Hannover Med Sch, Inst Lab Anim Sci & Cent Anim Facil, Hannover, Germany
关键词
image quality; interventional radiology; radiation dose; animal study; phantom study; fluoroscopy; AIR GAPS; MANAGEMENT; REDUCTION; SYSTEM;
D O I
10.1097/RLI.0000000000001079
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: This phantom and animal pilot study aimed to compare image quality and radiation exposure between detector-dose-driven exposure control (DEC) and contrast-to-noise ratio (CNR)-driven exposure control (CEC) as functions of source-to-image receptor distance (SID) and collimation. Materials and Methods: First, an iron foil simulated a guide wire in a stack of polymethyl methacrylate and aluminum plates representing patient thicknesses of 15, 25, and 35 cm. Fluoroscopic images were acquired using 5 SIDs ranging from 100 to 130 cm and 2 collimations (full field of view, collimated field of view: 6 x 6 cm). The iron foil CNRs were calculated, and radiation doses in terms of air kerma rate were obtained and assessed using a multivariate regression. Second, 5 angiographic scenarios were created in 2 anesthetized pigs. Fluoroscopic images were acquired at 2 SIDs (110 and 130 cm) and both collimations. Two blinded experienced readers compared image quality to the reference image using full field of view at an SID of 110 cm. Air kerma rate was obtained and compared using t tests. Results: Using DEC, both CNR and air kerma rate increased significantly at longer SID and collimation below the air kerma rate limit. When using CEC, CNR was significantly less dependent of SID, collimation, and patient thickness. Air kerma rate decreased at longer SID and tighter collimation. After reaching the air kerma rate limit, CEC behaved similarly to DEC. In the animal study using DEC, image quality and air kerma rate increased with longer SID and collimation (P < 0.005). Using CEC, image quality was not significantly different than using longer SID or tighter collimation. Air kerma rate was not significantly different at longer SID but lower using collimation (P = 0.012). Conclusions: CEC maintains the image quality with varying SID and collimation stricter than DEC, does not increase the air kerma rate at longer SID and reduces it with tighter collimation. After reaching the air kerma rate limit, CEC and DEC perform similarly.
引用
收藏
页码:711 / 718
页数:8
相关论文
共 50 条
  • [31] Supine and erect abdominal radiography: A comparison of radiation dose and image quality
    Alzyoud, Kholoud
    Al-Murshedi, Sadeq
    Abualkhael, Khaleda
    Alqawasmeh, Farah
    England, Andrew
    APPLIED RADIATION AND ISOTOPES, 2022, 190
  • [32] Effect of automatic tube voltage selection on image quality and radiation dose in abdominal CT angiography of various body sizes: A phantom study
    Schindera, S. T.
    Winklehner, A.
    Alkadhi, H.
    Goetti, R.
    Fischer, M.
    Gnannt, R.
    Szucs-Farkas, Z.
    CLINICAL RADIOLOGY, 2013, 68 (02) : E79 - E86
  • [33] PAE planning: Radiation exposure and image quality of CT and CBCT
    Steiniger, Beatrice
    Fiebich, Martin
    Grimm, Marc-Oliver
    Malouhi, Amer
    Reichenbach, Jurgen R.
    Scheithauer, Marcel
    Teichgraeber, Ulf
    Franiel, Tobias
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 172
  • [34] A multihospital survey of radiation exposure and image quality in pediatric fluoroscopy
    Brown, PH
    Silberberg, PJ
    Thomas, RD
    Strife, JL
    Towbin, RB
    PEDIATRIC RADIOLOGY, 2000, 30 (04) : 236 - 242
  • [35] A multihospital survey of radiation exposure and image quality in pediatric fluoroscopy
    P. H. Brown
    P. J. Silberberg
    R. D. Thomas
    J. L. Strife
    R. B. Towbin
    Pediatric Radiology, 2000, 30 : 236 - 242
  • [36] Image quality and radiation exposure at pulmonary CT angiography with 100-or 120-kVp protocol: prospective randomized study
    Heyer, Christoph M.
    Mohr, Patrick S.
    Lemburg, Stefan P.
    Peters, Soeren A.
    Nicolas, Volkmar
    RADIOLOGY, 2007, 245 (02) : 577 - 583
  • [37] Right lateral versus left lateral view for forearm coronary angiography. An operator radiation exposure and image quality study
    Rodriguez-Gonzalez, Elena
    Castanedo-Alvarez, Miguel
    Leon-Aliz, Ebrey
    Benitez-Peyrat, Jaime
    Francisco Oteo, Juan
    Hernandez-Hernandez, Monica
    Montes-Uruen, Alfredo
    Gorigolzarri-Artaza, Josebe
    Alejandra Restrepo-Cordoba, Maria
    Pifarre-Martinez, Xavier
    Goicolea, Javier
    Garcia-Touchard, Arturo
    JOURNAL OF RADIOLOGICAL PROTECTION, 2017, 37 (02) : 450 - 458
  • [38] CT angiography for planning transcatheter aortic valve replacement using automated tube voltage selection: Image quality and radiation exposure
    Mangold, Stefanie
    De Cecco, Carlo N.
    Schoepf, U. Joseph
    Kuhlman, Taylor S.
    Varga-Szemes, Akos
    Caruso, Damiano
    Duguay, Taylor M.
    Tesche, Christian
    Vogl, Thomas J.
    Nikolaou, Konstantin
    Steinberg, Daniel H.
    Wichmann, Julian L.
    EUROPEAN JOURNAL OF RADIOLOGY, 2017, 86 : 276 - 283
  • [39] LOW FRAME RATE SCREENING DURING INVASIVE CORONARY ANGIOGRAPHY SIGNIFICANTLY REDUCES RADIATION EXPOSURE AND GIVES GOOD IMAGE QUALITY
    Venables, P. A.
    Gosling, O.
    Loo, B. L. K.
    Wilson, S. J.
    Suresh, V.
    Tomlinson, D. R.
    HEART, 2010, 96 : A32 - A32
  • [40] Radiation dose and image quality with dual source computer tomography coronary angiography
    Vazquez, M.
    Tardaguila, G.
    Delgado, C.
    Calatayud, J.
    Castellon, D.
    Vilar, M.
    Sanmartin, M.
    Tardaguila, F.
    EUROPEAN HEART JOURNAL, 2011, 32 : 525 - 525