Using Patient-Specific Contrast Enhancement Optimizer Simulation Software During the Transcatheter Aortic Valve Implantation-Computed Tomography Angiography in Patients With Aortic Stenosis

被引:0
|
作者
Masuda, Takanori [1 ]
Nakaura, Takeshi [2 ]
Higaki, Toru [3 ]
Funama, Yoshinori [4 ]
Matsumoto, Yoriaki [3 ]
Sato, Tomoyasu [5 ]
Okimoto, Tomokazu [6 ]
Arao, Keiko [1 ]
Imaizumi, Hiromasa [1 ]
Arao, Shinichi [1 ]
Ono, Atsushi [1 ]
Hiratsuka, Junichi [1 ]
Awai, Kazuo [3 ]
机构
[1] Kawasaki Univ Med Welf, Fac Hlth Sci & Technol, Dept Radiol Technol, 288 Matsushima, Kurashiki, Okayama 7010193, Japan
[2] Kumamoto Univ, Grad Sch Med Sci, Dept Diagnost Radiol, Kumamoto, Japan
[3] Hiroshima Univ, Grad Sch Biomed Sci, Dept Diagnost Radiol, Hiroshima, Japan
[4] Kumamoto Univ, Fac Life Sci, Dept Med Phys, Kumamoto, Japan
[5] Tsuchiya Gen Hosp, Dept Diagnost Radiol, Naka Ku, Hiroshima, Japan
[6] Edogawa Hosp, Dept Cardiovasc Internal Med, Tokyo, Japan
关键词
contrast enhancement optimizer simulation software; transcatheter aortic valve implantation; computed tomography angiography; contrast material; contrast enhancement; TAVI - Transcatheter aortic valve implantation; AS - aortic stenosis; CTA - contrast tomography angiography; CM - contrast materials; HU - Hounsfield units; p-COP - optimizer simulation software; CT - computed tomography; CO - cardiac output; BW - body weight; CT; VOLUME; WEIGHT; TAVI;
D O I
10.1097/RCT.0000000000001603
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: This study assessed whether patient-specific contrast enhancement optimizer simulation software (p-COP) can reduce the contrast material (CM) dose compared with the conventional body weight (BW)-tailored scan protocol during transcatheter aortic valve implantation-computed tomography angiography (TAVI-CTA) in patients with aortic stenosis. Methods: We used the CM injection protocol selected by the p-COP in group A (n = 30). p-COP uses an algorithm that concerns data on an individual patient's cardiac output. Group B (n = 30) was assigned to the conventional BW-tailored CM injection protocol group. We compared the CM dose, CM amount, injection rate, and computed tomography (CT) values in the abdominal aorta between the 2 groups and classified them as acceptable (>280 Hounsfield units (HU)) or unacceptable (<279 HU) based on the optimal CT value and visualization scores for TAVI-CTA. We used the Mann-Whitney U test to compare patient characteristics and assess the interpatient variability of subjects in both groups. Results: Group A received 56.2 mL CM and 2.6 mL/s of injection, whereas group B received 76.9 mL CM and 3.4 mL/s of injection (P < 0.01). The CT value for the abdominal aorta at the celiac level was 287.0 HU in group A and 301.7HU in group B (P = 0.46). The acceptable (>280 HU) and unacceptable (<280 HU) CT value rates were 22 and 8 patients in group A and 24 and 6 patients in group B, respectively (P = 0.76). We observed no significant differences in the visualization scores between groups A and B (visualization score = 3, P = 0.71). Conclusion: The utilization of p-COP may decrease the CM dosage and injection rate by approximately 30% in individuals with aortic stenosis compared with the body-weight-tailored scan protocol during TAVI-CTA.
引用
收藏
页码:759 / 762
页数:4
相关论文
共 50 条
  • [31] Diagnostic performance of quantitative coronary artery disease assessment using computed tomography in patients with aortic stenosis undergoing transcatheter aortic-valve implantation
    Malebranche, Daniel
    Hoffner, Maximilian K. M.
    Huber, Adrian T.
    Cicovic, Aleksandar
    Spano, Giancarlo
    Bernhard, Benedikt
    Bartkowiak, Joanna
    Okuno, Taishi
    Lanz, Jonas
    Raber, Lorenz
    Praz, Fabien
    Stortecky, Stefan
    Windecker, Stephan
    Pilgrim, Thomas
    Grani, Christoph
    BMC CARDIOVASCULAR DISORDERS, 2022, 22 (01)
  • [32] Computed Tomography Score of Aortic Valve Tissue May Predict Cerebral Embolism During Transcatheter Aortic Valve Implantation
    Tada, Norio
    Haga, Yoshihiro
    Suzuki, Shinichi
    Enta, Yusuke
    Miyasaka, Masaki
    Inoue, Hiroshi
    Taguri, Masataka
    Ishii, Kiyoshi
    Hata, Masaki
    Sakuma, Masashi
    Toyoda, Shigeru
    Inoue, Teruo
    Ootomo, Tatsushi
    JACC-CARDIOVASCULAR IMAGING, 2017, 10 (08) : 960 - 962
  • [33] Patient-specific finite element analysis of transcatheter aortic valve implantation: a clinical case
    Finotello, A.
    Morganti, S.
    Brambilla, N.
    Bedogni, F.
    Auricchio, F.
    EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, 2017, 47 : 110 - 110
  • [34] Simulated Prosthesis Overlay for Patient-Specific Planning of Transcatheter Aortic Valve Implantation Procedures
    Suendermann, Simon H.
    Gessat, Michael
    Maier, Willibald
    Kempfert, Joerg
    Frauenfelder, Thomas
    Nguyen, Thi D. L.
    Maisano, Francesco
    Falk, Volkmar
    INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2015, 10 (05) : 314 - 322
  • [35] Patient-specific computer modelling – its role in the planning of transcatheter aortic valve implantation
    N. El Faquir
    B. Ren
    N. M. Van Mieghem
    J. Bosmans
    P. P. de Jaegere
    Netherlands Heart Journal, 2017, 25 : 100 - 105
  • [36] Patient-specific computer modelling - its role in the planning of transcatheter aortic valve implantation
    El Faquir, N.
    Ren, B.
    Van Mieghem, N. M.
    Bosmans, J.
    de Jaegere, P. P.
    NETHERLANDS HEART JOURNAL, 2017, 25 (02) : 100 - 105
  • [37] Computed tomography for the prediction of structural valve deterioration in patients undergoing transcatheter aortic valve implantation
    Guglielmo, Marco
    Fusini, Laura
    Muratori, Manuela
    Mantegazza, Valentina
    Muscogiuri, Giuseppe
    Baggiano, Andrea
    Scafuri, Stefano
    Babbaro, Mario
    Mollace, Rocco
    Collevecchio, Ada
    Mushtaq, Saima
    Conte, Edoardo
    Guaricci, AndreaIgoren
    Pepi, Mauro
    Pontone, Gianluca
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2020, 22 (0N) : N37 - N37
  • [38] Simulation of transcatheter aortic valve implantation through patient-specific finite element analysis: Two clinical cases
    Morganti, S.
    Conti, M.
    Aiello, M.
    Valentini, A.
    Mazzola, A.
    Reali, A.
    Auricchio, F.
    JOURNAL OF BIOMECHANICS, 2014, 47 (11) : 2547 - 2555
  • [39] Patient-Specific Computer Simulation to Predict Transcatheter Heart Valve Eccentricity in Bicuspid Aortic Valve
    Dargan, James
    Fyyaz, Saad
    Rocatello, Giorgia
    Weng, Yu
    Khan, Faisal
    Dowling, Cameron
    De Backer, Ole
    Esteban, Maite Tome
    Brecker, Stephen
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 84 (18) : B22 - B22
  • [40] Transcatheter aortic valve implantation using the Lotus valve system in severe aortic stenosis in an orthotopic heart transplant patient
    Kyranis, Stephen
    Markham, Ryan
    Platts, David
    Murdoch, Dale
    Walters, Darren
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2016, 207 : 192 - 193