Using Patient-Specific Contrast Enhancement Optimizer Simulation Software During the Transcatheter Aortic Valve Implantation-Computed Tomography Angiography in Patients With Aortic Stenosis

被引:0
|
作者
Masuda, Takanori [1 ]
Nakaura, Takeshi [2 ]
Higaki, Toru [3 ]
Funama, Yoshinori [4 ]
Matsumoto, Yoriaki [3 ]
Sato, Tomoyasu [5 ]
Okimoto, Tomokazu [6 ]
Arao, Keiko [1 ]
Imaizumi, Hiromasa [1 ]
Arao, Shinichi [1 ]
Ono, Atsushi [1 ]
Hiratsuka, Junichi [1 ]
Awai, Kazuo [3 ]
机构
[1] Kawasaki Univ Med Welf, Fac Hlth Sci & Technol, Dept Radiol Technol, 288 Matsushima, Kurashiki, Okayama 7010193, Japan
[2] Kumamoto Univ, Grad Sch Med Sci, Dept Diagnost Radiol, Kumamoto, Japan
[3] Hiroshima Univ, Grad Sch Biomed Sci, Dept Diagnost Radiol, Hiroshima, Japan
[4] Kumamoto Univ, Fac Life Sci, Dept Med Phys, Kumamoto, Japan
[5] Tsuchiya Gen Hosp, Dept Diagnost Radiol, Naka Ku, Hiroshima, Japan
[6] Edogawa Hosp, Dept Cardiovasc Internal Med, Tokyo, Japan
关键词
contrast enhancement optimizer simulation software; transcatheter aortic valve implantation; computed tomography angiography; contrast material; contrast enhancement; TAVI - Transcatheter aortic valve implantation; AS - aortic stenosis; CTA - contrast tomography angiography; CM - contrast materials; HU - Hounsfield units; p-COP - optimizer simulation software; CT - computed tomography; CO - cardiac output; BW - body weight; CT; VOLUME; WEIGHT; TAVI;
D O I
10.1097/RCT.0000000000001603
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: This study assessed whether patient-specific contrast enhancement optimizer simulation software (p-COP) can reduce the contrast material (CM) dose compared with the conventional body weight (BW)-tailored scan protocol during transcatheter aortic valve implantation-computed tomography angiography (TAVI-CTA) in patients with aortic stenosis. Methods: We used the CM injection protocol selected by the p-COP in group A (n = 30). p-COP uses an algorithm that concerns data on an individual patient's cardiac output. Group B (n = 30) was assigned to the conventional BW-tailored CM injection protocol group. We compared the CM dose, CM amount, injection rate, and computed tomography (CT) values in the abdominal aorta between the 2 groups and classified them as acceptable (>280 Hounsfield units (HU)) or unacceptable (<279 HU) based on the optimal CT value and visualization scores for TAVI-CTA. We used the Mann-Whitney U test to compare patient characteristics and assess the interpatient variability of subjects in both groups. Results: Group A received 56.2 mL CM and 2.6 mL/s of injection, whereas group B received 76.9 mL CM and 3.4 mL/s of injection (P < 0.01). The CT value for the abdominal aorta at the celiac level was 287.0 HU in group A and 301.7HU in group B (P = 0.46). The acceptable (>280 HU) and unacceptable (<280 HU) CT value rates were 22 and 8 patients in group A and 24 and 6 patients in group B, respectively (P = 0.76). We observed no significant differences in the visualization scores between groups A and B (visualization score = 3, P = 0.71). Conclusion: The utilization of p-COP may decrease the CM dosage and injection rate by approximately 30% in individuals with aortic stenosis compared with the body-weight-tailored scan protocol during TAVI-CTA.
引用
收藏
页码:759 / 762
页数:4
相关论文
共 50 条
  • [11] Utility of computed tomography in cases of aortic valve stenosis before and after transcatheter aortic valve implantation
    Takaoka, Hiroyuki
    Kitahara, Hideki
    Ota, Joji
    Suzuki-Eguchi, Noriko
    Sasaki, Haruka
    Mori, Naoto
    Takahashi, Manami
    Iida, Yasunori
    Matsuura, Kaoru
    Nakayama, Takashi
    Matsumiya, Goro
    Kobayashi, Yoshio
    CARDIOVASCULAR INTERVENTION AND THERAPEUTICS, 2020, 35 (01) : 72 - 84
  • [12] Utility of computed tomography in cases of aortic valve stenosis before and after transcatheter aortic valve implantation
    Hiroyuki Takaoka
    Hideki Kitahara
    Joji Ota
    Noriko Suzuki-Eguchi
    Haruka Sasaki
    Naoto Mori
    Manami Takahashi
    Yasunori Iida
    Kaoru Matsuura
    Takashi Nakayama
    Goro Matsumiya
    Yoshio Kobayashi
    Cardiovascular Intervention and Therapeutics, 2020, 35 : 72 - 84
  • [13] Fluid Simulation of a Transcatheter Aortic Valve Deployment into a Patient-Specific Aortic Root
    Sirois E.
    Wang Q.
    Sun W.
    Cardiovascular Engineering and Technology, 2011, 2 (3) : 186 - 195
  • [14] Transapical Angiography in a Patient With Severe Aortic Stenosis Undergoing Transapical Transcatheter Aortic Valve Implantation
    Franz, Norbert
    Hofmann, Steffen
    Billion, Michael
    Ferdosi, Abbas
    Kowalski, Marek
    Bramlage, Peter
    Warnecke, Henning
    ANNALS OF THORACIC SURGERY, 2013, 96 (06): : E151 - E153
  • [15] A patient-specific mass-spring model for biomechanical simulation of aortic root tissue during transcatheter aortic valve implantation
    Cristoforetti, Alessandro
    Mase, Michela
    Bonmassari, Roberto
    Dallago, Michele
    Nollo, Giandomenico
    Ravelli, Flavia
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (08):
  • [16] Fluid Structure Interaction on Paravalvular Leakage of Transcatheter Aortic Valve Implantation Related to Aortic Stenosis: A Patient-Specific Case
    Basri, Adi A.
    Zuber, Mohammad
    Basri, Ernnie, I
    Zakaria, Muhammad S.
    Aziz, Ahmad F. A.
    Tamagawa, Masaaki
    Ahmad, Kamarul A.
    COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2020, 2020
  • [17] Patient-Specific Computer Simulation of Transcatheter Aortic Valve Replacement in Bicuspid Aortic Valve Morphology
    Dowling, Cameron
    Bavo, Alessandra M.
    El Faquir, Nahid
    Mortier, Peter
    de Jaegere, Peter
    De Backer, Ole
    Sondergaard, Lars
    Ruile, Philipp
    Mylotte, Darren
    McConkey, Hannah
    Rajani, Ronak
    Laborde, Jean-Claude
    Brecker, Stephen J.
    CIRCULATION-CARDIOVASCULAR IMAGING, 2019, 12 (10)
  • [18] PATIENT-SPECIFIC COMPUTATIONAL SIMULATIONS OF TRANSCATHETER AORTIC VALVE IMPLANTATION (TAVI)
    Bosi, Giorgia M.
    Capelli, Claudio
    Chung, Robin
    Mullen, Michael
    Taylor, Andrew M.
    Schievano, Silvia
    ASME 2013 CONFERENCE ON FRONTIERS IN MEDICAL DEVICES: APPLICATIONS OF COMPUTER MODELING AND SIMULATION, 2013,
  • [19] Objective quantification of aortic valvular structures by cardiac computed tomography angiography in patients considered for transcatheter aortic valve implantation
    Korosoglou, Grigorios
    Gitsioudis, Gitsios
    Waechter-Stehle, Irina
    Weese, Juergen
    Krumsdorf, Ulrike
    Chorianopoulos, Emmanuel
    Hosch, Waldemar
    Kauczor, Hans-Ulrich
    Katus, Hugo A.
    Bekeredjian, Raffi
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 81 (01) : 148 - 159
  • [20] Effect of aortic valve calcification as measured by computed tomography in patients undergoing transcatheter aortic valve implantation
    Stathogiannis, K.
    Toutouzas, K.
    Drakopoulou, M.
    Latsios, G.
    Synetos, A.
    Oikonomou, G.
    Xanthopoulou, M.
    Trantalis, G.
    Papanikolaou, A.
    Peskesis, G.
    Tsiamis, E.
    Tousoulis, D.
    EUROPEAN HEART JOURNAL, 2018, 39 : 1081 - 1081