Using Patient-Specific Contrast Enhancement Optimizer Simulation Software During the Transcatheter Aortic Valve Implantation-Computed Tomography Angiography in Patients With Aortic Stenosis

被引:0
|
作者
Masuda, Takanori [1 ]
Nakaura, Takeshi [2 ]
Higaki, Toru [3 ]
Funama, Yoshinori [4 ]
Matsumoto, Yoriaki [3 ]
Sato, Tomoyasu [5 ]
Okimoto, Tomokazu [6 ]
Arao, Keiko [1 ]
Imaizumi, Hiromasa [1 ]
Arao, Shinichi [1 ]
Ono, Atsushi [1 ]
Hiratsuka, Junichi [1 ]
Awai, Kazuo [3 ]
机构
[1] Kawasaki Univ Med Welf, Fac Hlth Sci & Technol, Dept Radiol Technol, 288 Matsushima, Kurashiki, Okayama 7010193, Japan
[2] Kumamoto Univ, Grad Sch Med Sci, Dept Diagnost Radiol, Kumamoto, Japan
[3] Hiroshima Univ, Grad Sch Biomed Sci, Dept Diagnost Radiol, Hiroshima, Japan
[4] Kumamoto Univ, Fac Life Sci, Dept Med Phys, Kumamoto, Japan
[5] Tsuchiya Gen Hosp, Dept Diagnost Radiol, Naka Ku, Hiroshima, Japan
[6] Edogawa Hosp, Dept Cardiovasc Internal Med, Tokyo, Japan
关键词
contrast enhancement optimizer simulation software; transcatheter aortic valve implantation; computed tomography angiography; contrast material; contrast enhancement; TAVI - Transcatheter aortic valve implantation; AS - aortic stenosis; CTA - contrast tomography angiography; CM - contrast materials; HU - Hounsfield units; p-COP - optimizer simulation software; CT - computed tomography; CO - cardiac output; BW - body weight; CT; VOLUME; WEIGHT; TAVI;
D O I
10.1097/RCT.0000000000001603
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: This study assessed whether patient-specific contrast enhancement optimizer simulation software (p-COP) can reduce the contrast material (CM) dose compared with the conventional body weight (BW)-tailored scan protocol during transcatheter aortic valve implantation-computed tomography angiography (TAVI-CTA) in patients with aortic stenosis. Methods: We used the CM injection protocol selected by the p-COP in group A (n = 30). p-COP uses an algorithm that concerns data on an individual patient's cardiac output. Group B (n = 30) was assigned to the conventional BW-tailored CM injection protocol group. We compared the CM dose, CM amount, injection rate, and computed tomography (CT) values in the abdominal aorta between the 2 groups and classified them as acceptable (>280 Hounsfield units (HU)) or unacceptable (<279 HU) based on the optimal CT value and visualization scores for TAVI-CTA. We used the Mann-Whitney U test to compare patient characteristics and assess the interpatient variability of subjects in both groups. Results: Group A received 56.2 mL CM and 2.6 mL/s of injection, whereas group B received 76.9 mL CM and 3.4 mL/s of injection (P < 0.01). The CT value for the abdominal aorta at the celiac level was 287.0 HU in group A and 301.7HU in group B (P = 0.46). The acceptable (>280 HU) and unacceptable (<280 HU) CT value rates were 22 and 8 patients in group A and 24 and 6 patients in group B, respectively (P = 0.76). We observed no significant differences in the visualization scores between groups A and B (visualization score = 3, P = 0.71). Conclusion: The utilization of p-COP may decrease the CM dosage and injection rate by approximately 30% in individuals with aortic stenosis compared with the body-weight-tailored scan protocol during TAVI-CTA.
引用
收藏
页码:759 / 762
页数:4
相关论文
共 50 条
  • [21] Aortic valve stenosis: computed tomography prior to transcatheter aortic valve implantation (TAVI). How can the outcome be improved?
    Hell, M.
    Achenbach, S.
    Arnold, M.
    HERZ, 2015, 40 (04) : 576 - 582
  • [22] Ongoing Experience With Patient-Specific Computer Simulation of Transcatheter Aortic Valve Replacement in Bicuspid Aortic Valve
    Dowling, Cameron
    Gooley, Robert
    McCormick, Liam
    Firoozi, Sami
    Brecker, Stephen
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 76 (17) : B53 - B53
  • [23] Ongoing Experience With Patient-Specific Computer Simulation of Transcatheter Aortic Valve Replacement in Bicuspid Aortic Valve
    Dowling, Cameron
    Gooley, Robert
    McCormick, Liam
    Sharma, Rahul P.
    Yeung, Alan C.
    Fearon, William F.
    Dargan, James
    Khan, Faisal
    Firoozi, Sami
    Brecker, Stephen J.
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2023, 51 : 31 - 37
  • [24] Preoperative computed tomography-imaging with patient-specific computer simulation in transcatheter aortic valve implantation: Design and rationale of the GUIDE-TAVI trial
    Hegeman, Romy R. M. J. J.
    van Ginkel, Dirk-Jan
    Laengle, Severin
    Timmers, Leo
    Rensing, Benno J. W. M.
    de Kroon, Thomas L.
    Sonker, Uday
    Kelder, Johannes C.
    Mach, Markus
    Andreas, Martin
    Swaans, Martin J.
    ten Berg, Jurrien M.
    Klein, Patrick
    AMERICAN HEART JOURNAL, 2024, 269 : 158 - 166
  • [25] Lifetime Management of Patients With Symptomatic Severe Aortic Stenosis: A Computed Tomography Simulation of Serial Transcatheter Aortic Valve Replacements
    Medranda, Giorgio
    Jimenez, Cesar Soria
    Case, Brian
    Ali, Syed
    Shea, Corey
    Zhang, Cheng
    Asch, Federico
    Weissman, Gaby
    Shults, Christian
    Garcia-Garcia, Hector
    Ben-Dor, Itsik
    Satler, Lowell
    Waksman, Ron
    Rogers, Toby
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 78 (19) : B22 - B23
  • [26] Screening For Pulmonary Hypertension With Multidetector Computed Tomography Among Patients With Severe Aortic Stenosis Undergoing Transcatheter Aortic Valve Implantation
    O'Sullivan, Crochan J.
    Montalbetti, Matteo
    Zbinden, Rainer
    Kurz, David J.
    Bernheim, Alain M.
    Liew, Aaron
    Meyer, Matthias R.
    Tuller, David
    Eberli, Franz R.
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2018, 5
  • [27] Prevalence of coronary artery disease among patients with bicuspid aortic valve stenosis undergoing computed tomography before transcatheter aortic valve implantation
    Wiessman, M.
    Aviv, Y.
    Shafir, G.
    Kornowski, R.
    Hamdan, A.
    EUROPEAN HEART JOURNAL, 2021, 42 : 202 - 202
  • [28] Computed Tomography Angiography for the Diagnosis of Coronary Artery Disease Among Patients Undergoing Transcatheter Aortic Valve Implantation
    Meier, David
    Depierre, Arnaud
    Topolsky, Antoine
    Roguelov, Christan
    Dupre, Marion
    Rubimbura, Vladimir
    Eeckhout, Eric
    Qanadli, Salah Dine
    Muller, Olivier
    Mahendiran, Thabo
    Rotzinger, David
    Fournier, Stephane
    JOURNAL OF CARDIOVASCULAR TRANSLATIONAL RESEARCH, 2021, 14 (05) : 894 - 901
  • [29] Computed Tomography Angiography for the Diagnosis of Coronary Artery Disease Among Patients Undergoing Transcatheter Aortic Valve Implantation
    David Meier
    Arnaud Depierre
    Antoine Topolsky
    Christan Roguelov
    Marion Dupré
    Vladimir Rubimbura
    Eric Eeckhout
    Salah Dine Qanadli
    Olivier Muller
    Thabo Mahendiran
    David Rotzinger
    Stephane Fournier
    Journal of Cardiovascular Translational Research, 2021, 14 : 894 - 901
  • [30] Diagnostic performance of quantitative coronary artery disease assessment using computed tomography in patients with aortic stenosis undergoing transcatheter aortic-valve implantation
    Daniel Malebranche
    Maximilian K. M. Hoffner
    Adrian T. Huber
    Aleksandar Cicovic
    Giancarlo Spano
    Benedikt Bernhard
    Joanna Bartkowiak
    Taishi Okuno
    Jonas Lanz
    Lorenz Räber
    Fabien Praz
    Stefan Stortecky
    Stephan Windecker
    Thomas Pilgrim
    Christoph Gräni
    BMC Cardiovascular Disorders, 22