Stitching interferometry for long X-ray mirrors with lateral multi-shift-based absolute calibration

被引:2
|
作者
Zhou, Guang [1 ,2 ]
Wang, Jiezhuo [1 ,2 ]
Lei, Weizheng [3 ]
Dong, Xiaohao [1 ,3 ]
Wang, Jie [1 ,3 ]
机构
[1] Chinese Acad Sci, Shanghai Inst Appl Phys, Shanghai 201800, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[3] Chinese Acad Sci, Shanghai Adv Res Inst, Shanghai 201210, Peoples R China
关键词
ACCURACY;
D O I
10.1364/AO.516190
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
To eliminate the reference mirror (REF) error of the Fizeau interferometer for measuring X-ray mirrors, the reference calibration method of lateral multi-shift measurements at the hundreds-micrometer pixel level is presented. Because of the high aspect ratio of long X-ray mirrors, by shifting the surface under test (SUT) along the tangential direction with integer multiple pixels, we extend the calibration method by using the difference between multiple shifted measurements to build an augmented multi-matrix for extracting the two-dimensional (2D) absolute surface. The method can be applied to arbitrary measurement regions of the test optics, and the measurement for both the benchmark sub-aperture and calibration of the REF is accomplished in a single measuring process. Furthermore, by adjusting the shift to the millimeter scale, reference-subtracted sub-apertures can be stitched to obtain the absolute 2D map of the X-ray mirror. Experimental results show that all the 2D discrepancies reach subnanometer repeatability, and comparison results between the long trace profiler (LTP) and the proposed method have been performed. Therefore, the results demonstrated that the proposed method meets the requirements of X-ray mirror measurements. (c) 2024 Optica Publishing Group
引用
收藏
页码:2086 / 2094
页数:9
相关论文
共 50 条
  • [31] Fabrication and absolute calibration of X-ray streak camera cathode
    Li, Jin
    Hu, Xin
    Fan, Long
    Chen, Tao
    Yang, Zhiwen
    Deng, Bo
    Li, Yukun
    Cao, Zhurong
    Liu, Shenye
    Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams, 2015, 27 (08):
  • [32] Use of scattered radiation for absolute x-ray energy calibration
    Cross, Julie O.
    Frenkel, Anatoly I.
    Review of Scientific Instruments, 1999, 70 (1 pt 1):
  • [33] ABSOLUTE KVP CALIBRATION USING CHARACTERISTIC X-RAY YIELDS
    ANDERSON, DW
    MOORE, GJ
    LESTER, PD
    MEDICAL PHYSICS, 1986, 13 (05) : 663 - 666
  • [34] X-ray absolute calibration of the time response of a silicon photodiode
    Seely, JF
    Boyer, CN
    Holland, GE
    Weaver, JL
    APPLIED OPTICS, 2002, 41 (25) : 5209 - 5217
  • [35] Coherence-contrast x-ray imaging based on x-ray interferometry
    Yoneyama, A
    Takeda, T
    Tsuchiya, Y
    Wu, J
    Lwin, TT
    Hyodo, K
    APPLIED OPTICS, 2005, 44 (16) : 3258 - 3261
  • [36] Absolute calibration of a soft X-ray spectrograph for X-ray laser research using white beam
    Fujikawa, C
    Kawachi, T
    Ando, K
    Yamaguchi, N
    Hara, T
    JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 : 756 - 758
  • [37] Absolute X-ray energy calibration and monitoring using a diffraction-based method
    Hong, Xinguo
    Duffy, Thomas S.
    Ehm, Lars
    Weidner, Donald J.
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI2015), 2016, 1741
  • [38] Parallax-Free Long Bone X-ray Image Stitching
    Wang, Lejing
    Traub, Joerg
    Weidert, Simon
    Heining, Sandro Michael
    Euler, Ekkehard
    Navab, Nassir
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2009, PT I, PROCEEDINGS, 2009, 5761 : 173 - +
  • [39] SUB-NANOMETER DISPLACEMENTS CALIBRATION USING X-RAY INTERFEROMETRY
    BOWEN, DK
    CHETWYND, DG
    SCHWARZENBERGER, DR
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1990, 1 (02) : 107 - 119
  • [40] ABSOLUTE CALIBRATION OF X-RAY-FILMS OF THE SPACED X-RAY EMULSION CAMERA METHOD
    AKHMETOV, AK
    IZVESTIYA AKADEMII NAUK SSSR SERIYA FIZICHESKAYA, 1982, 46 (09): : 1797 - 1798