Absolute X-ray energy calibration and monitoring using a diffraction-based method

被引:0
|
作者
Hong, Xinguo [1 ]
Duffy, Thomas S. [2 ]
Ehm, Lars [1 ,3 ]
Weidner, Donald J. [1 ]
机构
[1] SUNY Stony Brook, Inst Mineral Phys, Stony Brook, NY 11794 USA
[2] Princeton Univ, Dept Geosci, Princeton, NJ 08544 USA
[3] Brookhaven Natl Lab, Natl Synchrotron Light Source 2, Upton, NY 11973 USA
关键词
X-Ray energy calibration; X-Ray energy monitoring; X-Ray diffraction;
D O I
10.1063/1.4952932
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this paper, we report some recent developments of the diffraction-based absolute X-ray energy calibration method. In this calibration method, high spatial resolution of the measured detector offset is essential. To this end, a remotely controlled long-translation motorized stage was employed instead of the less convenient gauge blocks. It is found that the precision of absolute X-ray energy calibration (Delta E/E) is readily achieved down to the level of 10(-4) for high -energy monochromatic X-rays (e.g. 80 keV). Examples of applications to pair distribution function (PDF) measurements and energy monitoring for high-energy X-rays are presented.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Absolute x-ray energy calibration over a wide energy range using a diffraction-based iterative method
    Hong, Xinguo
    Chen, Zhiqiang
    Duffy, Thomas S.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (06):
  • [2] Application of machine learning to X-ray diffraction-based classification
    Zhao, Bi
    Wolter, Scott
    Greenberg, Joel A.
    ANOMALY DETECTION AND IMAGING WITH X-RAYS (ADIX) III, 2018, 10632
  • [3] Impact of fat and muscle in energy dispersive X-ray diffraction-based identification of heroin using multivariate data analysis
    Li, Wei
    Zhang, Fang
    Yu, Daoyang
    Sun, Bai
    Li, Minqiang
    Liu, Jinhuai
    JOURNAL OF CHEMOMETRICS, 2011, 25 (12) : 631 - 635
  • [4] Determination of absolute configuration using X-ray diffraction
    Parsons, Simon
    TETRAHEDRON-ASYMMETRY, 2017, 28 (10) : 1304 - 1313
  • [5] Use of scattered radiation for absolute x-ray energy calibration
    Cross, JO
    Frenkel, AI
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (01): : 38 - 40
  • [6] Angular calibration in energy dispersive X-Ray diffraction by using genetic algorithms
    Brunetti, A.
    Albertini, V. Rossi
    Bailo, D.
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2009, 17 (03) : 253 - 264
  • [7] Use of scattered radiation for absolute x-ray energy calibration
    Cross, Julie O.
    Frenkel, Anatoly I.
    Review of Scientific Instruments, 1999, 70 (1 pt 1):
  • [8] X-ray beam monitoring and wavelength calibration using four-beam diffraction
    Huang, XianRong
    Shi, Xianbo
    Assoufid, Lahsen
    JOURNAL OF SYNCHROTRON RADIATION, 2022, 29 : 159 - 166
  • [9] ABSOLUTE KVP CALIBRATION USING CHARACTERISTIC X-RAY YIELDS
    ANDERSON, DW
    MOORE, GJ
    MEDICAL PHYSICS, 1986, 13 (04) : 593 - 593
  • [10] ABSOLUTE KVP CALIBRATION USING CHARACTERISTIC X-RAY YIELDS
    ANDERSON, DW
    MOORE, GJ
    LESTER, PD
    MEDICAL PHYSICS, 1986, 13 (05) : 663 - 666