Absolute X-ray energy calibration and monitoring using a diffraction-based method

被引:0
|
作者
Hong, Xinguo [1 ]
Duffy, Thomas S. [2 ]
Ehm, Lars [1 ,3 ]
Weidner, Donald J. [1 ]
机构
[1] SUNY Stony Brook, Inst Mineral Phys, Stony Brook, NY 11794 USA
[2] Princeton Univ, Dept Geosci, Princeton, NJ 08544 USA
[3] Brookhaven Natl Lab, Natl Synchrotron Light Source 2, Upton, NY 11973 USA
关键词
X-Ray energy calibration; X-Ray energy monitoring; X-Ray diffraction;
D O I
10.1063/1.4952932
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this paper, we report some recent developments of the diffraction-based absolute X-ray energy calibration method. In this calibration method, high spatial resolution of the measured detector offset is essential. To this end, a remotely controlled long-translation motorized stage was employed instead of the less convenient gauge blocks. It is found that the precision of absolute X-ray energy calibration (Delta E/E) is readily achieved down to the level of 10(-4) for high -energy monochromatic X-rays (e.g. 80 keV). Examples of applications to pair distribution function (PDF) measurements and energy monitoring for high-energy X-rays are presented.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Determination of the Absolute Orientation of Langatate Crystals Using X-ray Diffraction
    Sturtevant, B. T.
    da Cunha, M. Pereira
    Lad, R. J.
    2008 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4 AND APPENDIX, 2008, : 741 - +
  • [22] X-ray powder diffraction-based method for the determination of the glass content and mineralogy of coal (co)-combustion fly ashes
    Font, O.
    Moreno, N.
    Querol, X.
    Izquierdo, M.
    Alvarez, E.
    Diez, S.
    Elvira, J.
    Antenucci, D.
    Nugteren, H.
    Plana, F.
    Lopez, A.
    Coca, P.
    Pena, F. G.
    FUEL, 2010, 89 (10) : 2971 - 2976
  • [23] Diffraction-based self-calibration method for defocused speckle imaging
    Heikkinen, Juuso
    Schajer, Gary S.
    OPTICS AND LASERS IN ENGINEERING, 2022, 158
  • [24] Multilayer X-ray mirror calibration by an energy dispersive method using an X-ray tube and a Si(Li) detector. Absolute reflectivity, energy band pass, and overlapping order determination
    Dhez, P.
    Duval, H.
    Malaurent, J.C.
    Journal of X-Ray Science and Technology, 1992, 3 (03)
  • [25] METHOD OF CALIBRATION FOR LOW-ENERGY X-RAY BEAMS
    NUNNALLY, JE
    PHYSICS IN MEDICINE AND BIOLOGY, 1973, 18 (06): : 878 - 880
  • [26] X-ray diffraction-based characterization of magnetite nanoparticles in presence of goethite and correlation with magnetic properties
    Mahadevan, S.
    Gnanaprakash, G.
    Philip, J.
    Rao, B. P. C.
    Jayakumar, T.
    PHYSICA E-LOW-DIMENSIONAL SYSTEMS & NANOSTRUCTURES, 2007, 39 (01): : 20 - 25
  • [27] Calibration of the x-ray instruments for x-ray laser energy measurement
    Sakaya, N
    Tohyama, Y
    Sebban, S
    Daido, H
    Nishimura, H
    Kato, Y
    Murai, K
    Wang, S
    Gu, Y
    Huang, G
    Tang, H
    X-RAY LASERS 1998, 1999, 159 : 479 - 482
  • [28] Energy -: Dispersive X-ray diffraction
    Kämpfe, B
    Arnhold, R
    Michel, B
    APPLIED CRYSTALLIGRAPHY, 2004, : 27 - 30
  • [29] Energy dispersive X-ray diffraction
    Kaempfe, Bernd
    Luczak, Falk
    Michel, Bernd
    PARTICLE & PARTICLE SYSTEMS CHARACTERIZATION, 2006, 22 (06) : 391 - 396
  • [30] Spectrum-Based Calibration Method for Energy Discriminating CZT Detectors Using Commercial X-Ray Generators
    Xing, Xiaoman
    Xu, Pin
    Chen, Shi
    Yuan, Gang
    Mo, Jingqing
    Sun, Mingshan
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2017, 64 (05) : 1128 - 1132