Stitching interferometry for long X-ray mirrors with lateral multi-shift-based absolute calibration

被引:2
|
作者
Zhou, Guang [1 ,2 ]
Wang, Jiezhuo [1 ,2 ]
Lei, Weizheng [3 ]
Dong, Xiaohao [1 ,3 ]
Wang, Jie [1 ,3 ]
机构
[1] Chinese Acad Sci, Shanghai Inst Appl Phys, Shanghai 201800, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[3] Chinese Acad Sci, Shanghai Adv Res Inst, Shanghai 201210, Peoples R China
关键词
ACCURACY;
D O I
10.1364/AO.516190
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
To eliminate the reference mirror (REF) error of the Fizeau interferometer for measuring X-ray mirrors, the reference calibration method of lateral multi-shift measurements at the hundreds-micrometer pixel level is presented. Because of the high aspect ratio of long X-ray mirrors, by shifting the surface under test (SUT) along the tangential direction with integer multiple pixels, we extend the calibration method by using the difference between multiple shifted measurements to build an augmented multi-matrix for extracting the two-dimensional (2D) absolute surface. The method can be applied to arbitrary measurement regions of the test optics, and the measurement for both the benchmark sub-aperture and calibration of the REF is accomplished in a single measuring process. Furthermore, by adjusting the shift to the millimeter scale, reference-subtracted sub-apertures can be stitched to obtain the absolute 2D map of the X-ray mirror. Experimental results show that all the 2D discrepancies reach subnanometer repeatability, and comparison results between the long trace profiler (LTP) and the proposed method have been performed. Therefore, the results demonstrated that the proposed method meets the requirements of X-ray mirror measurements. (c) 2024 Optica Publishing Group
引用
收藏
页码:2086 / 2094
页数:9
相关论文
共 50 条
  • [41] A stitching figure profiler of large X-ray mirrors using RADSI for subaperture data acquisition
    Kimura, Takashi
    Ohashi, Haruhiko
    Mimura, Hidekazu
    Yamakawa, Daisuke
    Yumoto, Hirokatsu
    Matsuyama, Satoshi
    Tsumura, Takashi
    Okada, Hiromi
    Masunaga, Tatsuhiko
    Senba, Yasunori
    Goto, Shunji
    Ishikawa, Tetsuya
    Yamauchi, Kazuto
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 616 (2-3): : 229 - 232
  • [42] Clinical Application of CAMC - Long Bone X-Ray Image Stitching
    Heining, S. M.
    Wang, L.
    Navab, N.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 4: IMAGE PROCESSING, BIOSIGNAL PROCESSING, MODELLING AND SIMULATION, BIOMECHANICS, 2010, 25 : 2323 - 2325
  • [43] On controlling gravitational distortions in long synchrotron x-ray mirrors
    Ice, GE
    OPTICS FOR HIGH-BRIGHTNESS SYNCHROTRON RADIATION BEAMLINES II, 1996, 2856 : 157 - 162
  • [44] A SIMPLE MONOCHROMATOR BASED ON X-RAY MULTILAYER MIRRORS
    SMITH, A
    RIEDEL, C
    EDWARDS, B
    SAVAGE, D
    LAI, B
    RAYCHAUDHURI, A
    CERRINA, F
    LAGALLY, MG
    UNDERWOOD, J
    FALCO, C
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07): : 2003 - 2005
  • [45] Absolute calibration of the soft X-ray streak camera static characteristic
    Yi, RQ
    Zheng, ZJ
    Hu, X
    Cui, MQ
    Zhao, YD
    Zhu, PP
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2003, 27 (05): : 452 - 454
  • [46] Device for absolute calibration of spectral sensitivity of semiconductor X-ray detectors
    Kropotov, A.Yu.
    Morgun, O.N.
    Chernyi, V.V.
    Instruments and experimental techniques New York, 1988, 31 (3 pt 1): : 572 - 575
  • [47] Design and calibration of the measuring system for soft X-ray absolute intensity
    Cui, CW
    Cui, MQ
    Yi, RQ
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 1998, 22 (02): : 180 - 185
  • [48] Spherical grating based x-ray Talbot interferometry
    Cong, Wenxiang
    Xi, Yan
    Wang, Ge
    MEDICAL PHYSICS, 2015, 42 (11) : 6514 - 6519
  • [49] A novel multi-view X-ray digital imaging stitching algorithm
    Kang, Yang
    Wu, Rui
    Wu, Sen
    Li, Peizheng
    Li, Qingpei
    Cao, Kun
    Tan, Tingting
    Li, Yingrui
    Zha, Gangqiang
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2023, 31 (01) : 153 - 166
  • [50] ABSOLUTE REFLECTIVITY MEASUREMENTS AT 44.79-A OF SPUTTER DEPOSITED MULTILAYER X-RAY MIRRORS
    ARBAOUI, M
    BARCHEWITZ, R
    SELLA, C
    YOUN, KB
    APPLIED OPTICS, 1990, 29 (04): : 477 - 482