Dosimetry studies for an optimized reloading of a panoramic Cobalt-60 source using FLUKA Monte Carlo code

被引:0
|
作者
Hammami, Imen [1 ,2 ]
Bouabidi, Ammar [1 ,2 ,3 ]
Ayadi, Asma [1 ,2 ]
Ounalli, Leila [1 ,2 ]
机构
[1] Tunisian Ctr Nucl Sci & Technol, Technopark Sidi Thabet, Sidi Thabet, Tunisia
[2] Minist Higher Educ & Res, Res Lab Energy & Matter Nucl Sci Dev LR16CNSTN02, Tunis, Tunisia
[3] Univ Tunis Manar, Fac Sci Tunis, Tunis 2092, Tunisia
关键词
Reload; Cobalt-60; Monte Carlo; FLUKA; Dose rate; Uniformity; PREDICTIVE TOOL;
D O I
10.1016/j.nima.2024.169417
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Cobalt-60 source used at the Tunisian Gamma Irradiation Facility is nearing the end of its useful life. Due to the current low dose rates, the irradiation process takes a long time. To address exposure time and cost issues, source racks need to be reloaded to improve the quality of the exposure process. This work aims to find the optimal new configuration for future reloading of the Cobalt-60 source rack and to evaluate the dose rate distribution in the vicinity of the Irradiator and the Dose Uniformity Ratio (DUR) in a dummy product. When keeping old pencils, the optimal configuration will need to be adjusted to accommodate the new Cobalt-60 pencils. The replenishment method developed using FLUKA-based Monte Carlo code involved the addition of six new pencils: three in the upper top (outer) holder of the source rack and three in the lower bottom (inner) source holder. The spatial distribution of dose rates in the vicinity of the source rack before and after reloading was evaluated. For the radiation processing, the maximum and minimum absorbed dose in the dummy product were estimated to calculate the DUR value. The DUR value for a single-use medical product is about 2.5. The results obtained before and after reloading show that the spatial distribution of the dose rate is uniform for the proposed configurations, and has a value of approximately 0.4 kGy/h after reloading at the conveyor belt location.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Study of exposure buildup factors with detailed physics for cobalt-60 gamma source in water, iron, and lead using the MCNPX code
    Mustafa Mohammad Rafiei
    Hossein Tavakoli-Anbaran
    The European Physical Journal Plus, 133
  • [42] Monte Carlo Dosimetry of the 60Co Bebig High Dose Rate Source for Brachytherapy
    Campos, L. T.
    de Almeida, C. E. V.
    MEDICAL PHYSICS, 2016, 43 (06) : 3464 - 3464
  • [43] Investigation of an efficient source design for Cobalt-60-based tomotherapy using EGSnrc Monte Carlo simulations
    Joshi, Chandra P.
    Darko, Johnson
    Vidyasagar, P. B.
    Schreiner, L. John
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (03): : 575 - 592
  • [44] Dosimetric comparison between microSelectron iridium-192 and flexi cobalt-60 sources in high-dose-rate brachytherapy using Geant4 Monte Carlo code
    Gebremariam, Tsige Yhidego
    Geraily, Ghazale
    Jassim, Hussam Hameed
    Gholami, Somayeh
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2023, 15 (02) : 141 - 147
  • [45] Cellular dosimetry calculations for Strontium-90 using Monte Carlo code PENELOPE
    Hocine, Nora
    Farlay, Delphine
    Boivin, Georges
    Franck, Didier
    Agarande, Michelle
    INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 2014, 90 (11) : 953 - 958
  • [46] Dose Determination in a CT Control Room Using TLD and Monte-Carlo-Method-Based FLUKA Code
    Yesil, A. H.
    Aksu, M. G.
    Cecen, Y.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S772 - S772
  • [47] Investigation of mass attenuation coefficients of water, concrete and bakelite at different energies using the FLUKA Monte Carlo code
    Nilgun Demir
    Urkiye Akar Tarim
    Maria-Ana Popovici
    Zehra Nur Demirci
    Orhan Gurler
    Iskender Akkurt
    Journal of Radioanalytical and Nuclear Chemistry, 2013, 298 : 1303 - 1307
  • [48] Investigation of mass attenuation coefficients of water, concrete and bakelite at different energies using the FLUKA Monte Carlo code
    Demir, Nilgun
    Tarim, Urkiye Akar
    Popovici, Maria-Ana
    Demirci, Zehra Nur
    Gurler, Orhan
    Akkurt, Iskender
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2013, 298 (02) : 1303 - 1307
  • [49] A new method to calculate the response of the WENDI-II rem counter using the FLUKA Monte Carlo Code
    Jaegerhofer, Lukas
    Feldbaumer, Eduard
    Theis, Christian
    Roesler, Stefan
    Vincke, Helmut
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 691 : 81 - 85
  • [50] Combining Monte Carlo simulations and dosimetry measurements for process control in the Tunisian Cobalt-60irradiator after three half lives of the source
    Leila Ounalli
    Maroua Bhar
    Arbi Mejri
    Kais Manai
    Ammar Bouabidi
    Shayma Mohamed Abdallah
    Nafaa Reguigui
    Nuclear Science and Techniques, 2017, 28 (09) : 117 - 126