Dosimetry studies for an optimized reloading of a panoramic Cobalt-60 source using FLUKA Monte Carlo code

被引:0
|
作者
Hammami, Imen [1 ,2 ]
Bouabidi, Ammar [1 ,2 ,3 ]
Ayadi, Asma [1 ,2 ]
Ounalli, Leila [1 ,2 ]
机构
[1] Tunisian Ctr Nucl Sci & Technol, Technopark Sidi Thabet, Sidi Thabet, Tunisia
[2] Minist Higher Educ & Res, Res Lab Energy & Matter Nucl Sci Dev LR16CNSTN02, Tunis, Tunisia
[3] Univ Tunis Manar, Fac Sci Tunis, Tunis 2092, Tunisia
关键词
Reload; Cobalt-60; Monte Carlo; FLUKA; Dose rate; Uniformity; PREDICTIVE TOOL;
D O I
10.1016/j.nima.2024.169417
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Cobalt-60 source used at the Tunisian Gamma Irradiation Facility is nearing the end of its useful life. Due to the current low dose rates, the irradiation process takes a long time. To address exposure time and cost issues, source racks need to be reloaded to improve the quality of the exposure process. This work aims to find the optimal new configuration for future reloading of the Cobalt-60 source rack and to evaluate the dose rate distribution in the vicinity of the Irradiator and the Dose Uniformity Ratio (DUR) in a dummy product. When keeping old pencils, the optimal configuration will need to be adjusted to accommodate the new Cobalt-60 pencils. The replenishment method developed using FLUKA-based Monte Carlo code involved the addition of six new pencils: three in the upper top (outer) holder of the source rack and three in the lower bottom (inner) source holder. The spatial distribution of dose rates in the vicinity of the source rack before and after reloading was evaluated. For the radiation processing, the maximum and minimum absorbed dose in the dummy product were estimated to calculate the DUR value. The DUR value for a single-use medical product is about 2.5. The results obtained before and after reloading show that the spatial distribution of the dose rate is uniform for the proposed configurations, and has a value of approximately 0.4 kGy/h after reloading at the conveyor belt location.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Monte Carlo simulation of radiation beam of cobalt 60 source in reference conditions
    Vargas-Segura, Walter
    Cordero-Ramirez, Anthony
    TECNOLOGIA EN MARCHA, 2023, 36 (03):
  • [32] Commissioning dosimetry and in situ dose mapping of a semi-industrial Cobalt-60 gamma-irradiation facility using Fricke and Ceric-cerous dosimetry system and comparison with Monte Carlo simulation data
    Mortuza, Md Firoz
    Lepore, Luigi
    Khedkar, Kalpana
    Thangam, Saravanan
    Nahar, Arifatun
    Jamil, Hossen Mohammad
    Bandi, Laxminarayan
    Alam, Md Khorshed
    RADIATION PHYSICS AND CHEMISTRY, 2018, 144 : 256 - 264
  • [33] Assessment of MIRD data for internal dosimetry using the GATE Monte Carlo code
    Ali Asghar Parach
    Hossein Rajabi
    Mohammad Ali Askari
    Radiation and Environmental Biophysics, 2011, 50 : 441 - 450
  • [34] Assessment of MIRD data for internal dosimetry using the GATE Monte Carlo code
    Parach, Ali Asghar
    Rajabi, Hossein
    Askari, Mohammad Ali
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2011, 50 (03) : 441 - 450
  • [35] Assessment of the production of medical isotopes using the Monte Carlo code FLUKA: Simulations against experimental measurements
    Infantino, Angelo
    Oehlke, Elisabeth
    Mostacci, Domiziano
    Schaffer, Paul
    Trinczek, Michael
    Hoehr, Cornelia
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2016, 366 : 117 - 123
  • [36] Analysis of concrete labyrinth shielding and radiation dose for APF plasma focus neutron source by FLUKA Monte Carlo code
    M. J. Nemati
    M. Habibi
    R. Amrollahi
    Journal of Radioanalytical and Nuclear Chemistry, 2013, 295 : 221 - 226
  • [37] Shielding analysis of the SPES targets handling system and storage area using the Monte Carlo code FLUKA
    Donzella, A.
    Zenoni, A.
    Ferrari, M.
    Andrighetto, A.
    Ballan, M.
    Borgna, F.
    Corradetti, S.
    D'Agostini, F.
    Manzolaro, M.
    Monetti, A.
    Rossignoli, M.
    Scarpa, D.
    Turcato, D.
    Zanettin, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2020, 463 : 169 - 172
  • [38] Analysis of concrete labyrinth shielding and radiation dose for APF plasma focus neutron source by FLUKA Monte Carlo code
    Nemati, M. J.
    Habibi, M.
    Amrollahi, R.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2013, 295 (01) : 221 - 226
  • [39] Monte Carlo characterization of 169Yb as a high-dose-rate source for brachytherapy application by FLUKA code
    Anjomrouz, Marzieh
    Sadeghi, Mahdi
    Haddadi, Asghar
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (04): : 196 - 205
  • [40] Study of exposure buildup factors with detailed physics for cobalt-60 gamma source in water, iron, and lead using the MCNPX code
    Rafiei, Mustafa Mohammad
    Tavakoli-Anbaran, Hossein
    EUROPEAN PHYSICAL JOURNAL PLUS, 2018, 133 (12):