Assessment of MIRD data for internal dosimetry using the GATE Monte Carlo code

被引:0
|
作者
Ali Asghar Parach
Hossein Rajabi
Mohammad Ali Askari
机构
[1] Tarbiat Modares University,Department of Medical Physics, Faculty of Medical Sciences
来源
关键词
Photon Energy; Relative Difference; Altman Plot; Source Organ; Monte Carlo Code;
D O I
暂无
中图分类号
学科分类号
摘要
GATE/GEANT is a Monte Carlo code dedicated to nuclear medicine that allows calculation of the dose to organs of voxel phantoms. On the other hand, MIRD is a well-developed system for estimation of the dose to human organs. In this study, results obtained from GATE/GEANT using Snyder phantom are compared to published MIRD data. For this, the mathematical Snyder phantom was discretized and converted to a digital phantom of 100 × 200 × 360 voxels. The activity was considered uniformly distributed within kidneys, liver, lungs, pancreas, spleen, and adrenals. The GATE/GEANT Monte Carlo code was used to calculate the dose to the organs of the phantom from mono-energetic photons of 10, 15, 20, 30, 50, 100, 200, 500, and 1000 keV. The dose was converted into specific absorbed fraction (SAF) and the results were compared to the corresponding published MIRD data. On average, there was a good correlation (r2>0.99) between the two series of data. However, the GATE/GEANT data were on average −0.16 ± 6.22% lower than the corresponding MIRD data for self-absorption. Self-absorption in the lungs was considerably higher in the MIRD compared to the GATE/GEANT data, for photon energies of 10–20 keV. As for cross-irradiation to other organs, the GATE/GEANT data were on average +1.5 ± 8.1% higher than the MIRD data, for photon energies of 50–1000 keV. For photon energies of 10–30 keV, the relative difference was +7.5 ± 67%. It turned out that the agreement between the GATE/GEANT and the MIRD data depended upon absolute SAF values and photon energy. For 10–30 keV photons, where the absolute SAF values were small, the uncertainty was high and the effect of cross-section prominent, and there was no agreement between the GATE/GEANT results and the MIRD data. However, for photons of 50–1,000 keV, the bias was negligible and the agreement was acceptable.
引用
收藏
页码:441 / 450
页数:9
相关论文
共 50 条
  • [1] Assessment of MIRD data for internal dosimetry using the GATE Monte Carlo code
    Parach, Ali Asghar
    Rajabi, Hossein
    Askari, Mohammad Ali
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2011, 50 (03) : 441 - 450
  • [2] Geant4/GATE Monte Carlo Code for Internal Dosimetry Using Voxelized Phantom
    Kaddouch, S.
    El Khayati, N.
    MOSCOW UNIVERSITY PHYSICS BULLETIN, 2017, 72 (06) : 658 - 662
  • [3] Geant4/GATE Monte Carlo Code for Internal Dosimetry Using Voxelized Phantom
    S. Kaddouch
    N. El Khayati
    Moscow University Physics Bulletin, 2017, 72 : 658 - 662
  • [4] Patient dose comparison between GATE Monte Carlo voxelized dosimetry and MIRD method
    Kim, J.
    Lee, M.
    Kim, K.
    Lee, J.
    Yi, C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S398 - S398
  • [5] Internal dosimetry with the Monte Carlo code GATE: validation using the ICRP/ICRU female reference computational model
    Villoing, Daphnee
    Marcatili, Sara
    Garcia, Marie-Paule
    Bardies, Manuel
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (05): : 1885 - 1904
  • [6] Preclinical radiation internal dosimetry in the development of new radiopharmaceuticals using GATE Monte Carlo simulation
    Silva, Catherine C. O.
    Berdeguez, Mirta B. T.
    Barboza, Thiago
    Souza, Sergio A. L.
    Braz, Delson
    Silva, Ademir X.
    Sa, Lidia, V
    RADIATION PHYSICS AND CHEMISTRY, 2020, 173
  • [7] Validation of Monte Carlo code GATE on the ICRP/ICRU female reference computational phantom for internal dosimetry aspects.
    Villoing, D.
    Mauxion, T.
    Marcatili, S.
    Poirot, M.
    Bardies, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S161 - S161
  • [8] Dosimetry applications in GATE Monte Carlo toolkit
    Papadimitroulas, Panagiotis
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 41 : 136 - 140
  • [9] Monte Carlo simulation of NovalisTx linear accelerator using GATE/Geant4 code for dosimetry analysis
    Fathi, Ahmed
    Khobbaizi, Youness
    Nabil, Sanaa
    Ardouz, Anas
    Hasnaoui, Abdellatif
    Sbiaai, Khalid
    MATERIALS TODAY-PROCEEDINGS, 2022, 66 : 466 - 472
  • [10] A review of radiation dosimetry applications using the MCNP Monte Carlo code
    Solberg, TD
    DeMarco, JJ
    Chetty, IJ
    Mesa, AV
    Cagnon, CH
    Li, AN
    Mather, KK
    Medin, PM
    Arellano, AR
    Smathers, JB
    RADIOCHIMICA ACTA, 2001, 89 (4-5) : 337 - 355