Assessment of MIRD data for internal dosimetry using the GATE Monte Carlo code

被引:0
|
作者
Ali Asghar Parach
Hossein Rajabi
Mohammad Ali Askari
机构
[1] Tarbiat Modares University,Department of Medical Physics, Faculty of Medical Sciences
来源
关键词
Photon Energy; Relative Difference; Altman Plot; Source Organ; Monte Carlo Code;
D O I
暂无
中图分类号
学科分类号
摘要
GATE/GEANT is a Monte Carlo code dedicated to nuclear medicine that allows calculation of the dose to organs of voxel phantoms. On the other hand, MIRD is a well-developed system for estimation of the dose to human organs. In this study, results obtained from GATE/GEANT using Snyder phantom are compared to published MIRD data. For this, the mathematical Snyder phantom was discretized and converted to a digital phantom of 100 × 200 × 360 voxels. The activity was considered uniformly distributed within kidneys, liver, lungs, pancreas, spleen, and adrenals. The GATE/GEANT Monte Carlo code was used to calculate the dose to the organs of the phantom from mono-energetic photons of 10, 15, 20, 30, 50, 100, 200, 500, and 1000 keV. The dose was converted into specific absorbed fraction (SAF) and the results were compared to the corresponding published MIRD data. On average, there was a good correlation (r2>0.99) between the two series of data. However, the GATE/GEANT data were on average −0.16 ± 6.22% lower than the corresponding MIRD data for self-absorption. Self-absorption in the lungs was considerably higher in the MIRD compared to the GATE/GEANT data, for photon energies of 10–20 keV. As for cross-irradiation to other organs, the GATE/GEANT data were on average +1.5 ± 8.1% higher than the MIRD data, for photon energies of 50–1000 keV. For photon energies of 10–30 keV, the relative difference was +7.5 ± 67%. It turned out that the agreement between the GATE/GEANT and the MIRD data depended upon absolute SAF values and photon energy. For 10–30 keV photons, where the absolute SAF values were small, the uncertainty was high and the effect of cross-section prominent, and there was no agreement between the GATE/GEANT results and the MIRD data. However, for photons of 50–1,000 keV, the bias was negligible and the agreement was acceptable.
引用
收藏
页码:441 / 450
页数:9
相关论文
共 50 条
  • [21] Cellular dosimetry calculations for Strontium-90 using Monte Carlo code PENELOPE
    Hocine, Nora
    Farlay, Delphine
    Boivin, Georges
    Franck, Didier
    Agarande, Michelle
    INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 2014, 90 (11) : 953 - 958
  • [22] Visual Monte Carlo and its application to internal and external dosimetry
    Hunt, JG
    da Silva, FC
    de Souza-Santos, D
    Malatova, I
    Foltanova, S
    Dantas, BM
    Azeredo, A
    Isakson, M
    ADVANCED MONTE CARLO FOR RADIATION PHYSICS, PARTICLE TRANSPORT SIMULATION AND APPLICATIONS, 2001, : 345 - 350
  • [23] Monte Carlo based voxel phantoms for in vivo internal dosimetry
    Gomez Ros, J. M.
    Moraleda, M.
    Lopez, M. A.
    Navarro, T.
    Navarro, J. F.
    RADIATION PROTECTION DOSIMETRY, 2007, 125 (1-4) : 161 - 165
  • [24] A Monte Carlo method for calculating Bayesian uncertainties in internal dosimetry
    Puncher, M.
    Birchall, A.
    RADIATION PROTECTION DOSIMETRY, 2008, 132 (01) : 1 - 12
  • [25] Monte Carlo studies in the field of internal dosimetry of incorporated radionuclides
    Gualdrini, G
    COMPUTING RADIATION DOSIMETRY - CRD 2002, WORKSHOP PROCEEDINGS, 2004, : 125 - 146
  • [26] Measurements of dose point kernels using GATE Monte Carlo toolkit for personalized convolution dosimetry
    Tiwari, Ashok
    Graves, Stephen
    Sunderland, John
    JOURNAL OF NUCLEAR MEDICINE, 2019, 60
  • [27] Photon Dose Kernels Dataset for Nuclear Medicine Dosimetry, using the GATE Monte Carlo Toolkit
    Papadimitroulas, Panagiotis
    Loudos, George
    Georgoulias, Panagiotis
    Kagadis, George C.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 1390 - 1394
  • [28] Development of GATE Monte Carlo Code for Simulation and Dosimetry of New I-125 Seeds in Eye Plaque Brachytherapy
    Taherparvar, Payvand
    Fardi, Zeinab
    NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 55 (02) : 86 - 95
  • [29] PATIENT-SPECIFIC DOSIMETRY FOR PEDIATRIC IMAGING OF 99mTc-DIMERCAPTOSUCCINIC ACID WITH GATE MONTE CARLO CODE
    Bagheri, Mahmoud
    Parach, Ali Asghar
    Razavi-Ratki, Seid Kazem
    Nafisi-Moghadam, Reza
    Jelodari, Mohammad Ali
    RADIATION PROTECTION DOSIMETRY, 2018, 178 (02) : 213 - 222
  • [30] Development of GATE Monte Carlo Code for Simulation and Dosimetry of New I-125 Seeds in Eye Plaque Brachytherapy
    Payvand Taherparvar
    Zeinab Fardi
    Nuclear Medicine and Molecular Imaging, 2021, 55 : 86 - 95