Cellular dosimetry calculations for Strontium-90 using Monte Carlo code PENELOPE

被引:3
|
作者
Hocine, Nora [1 ]
Farlay, Delphine [2 ,3 ]
Boivin, Georges [2 ,3 ]
Franck, Didier [1 ]
Agarande, Michelle [1 ]
机构
[1] Inst Radioprotect & Surete Nucl, Lyon, France
[2] INSERM UMR 1033, Lyon, France
[3] Univ Lyon, Lyon, France
关键词
PENELOPE; MCNPX; MIRD; Sr-90; validation; cellular dosimetry; TRANSPORT; PHOTON;
D O I
10.3109/09553002.2014.955144
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose: To improve risk assessments associated with chronic exposure to Strontium-90 (Sr-90), for both the environment and human health, it is necessary to know the energy distribution in specific cells or tissue. Monte Carlo (MC) simulation codes are extremely useful tools for calculating deposition energy. The present work was focused on the validation of the MC code PENetration and Energy LOss of Positrons and Electrons (PENELOPE) and the assessment of dose distribution to bone marrow cells from punctual Sr-90 source localized within the cortical bone part. Materials and methods: S-values (absorbed dose per unit cumulated activity) calculations using Monte Carlo simulations were performed by using PENELOPE and Monte Carlo N-Particle eXtended (MCNPX). Cytoplasm, nucleus, cell surface, mouse femur bone and Sr-90 radiation source were simulated. Cells are assumed to be spherical with the radii of the cell and cell nucleus ranging from 2-10 mm. The Sr-90 source is assumed to be uniformly distributed in cell nucleus, cytoplasm and cell surface. Results: The comparison of S-values calculated with PENELOPE to MCNPX results and the Medical Internal Radiation Dose (MIRD) values agreed very well since the relative deviations were less than 4.5%. The dose distribution to mouse bone marrow cells showed that the cells localized near the cortical part received the maximum dose. Conclusion: The MC code PENELOPE may prove useful for cellular dosimetry involving radiation transport through materials other than water, or for complex distributions of radionuclides and geometries.
引用
收藏
页码:953 / 958
页数:6
相关论文
共 50 条
  • [1] Cellular dosimetry of strontium-90 using the Monte Carlo code MCNPX, detection and X-ray microanalysis
    Hocine, N.
    Farlay, D.
    Bertho, J. -M.
    Boivin, G.
    Desbree, A.
    Franck, D.
    Agarande, M.
    RADIOPROTECTION, 2014, 49 (02) : 101 - 105
  • [2] Calculations of electron fluence correction factors using the Monte Carlo code PENELOPE
    Siegbahn, EA
    Nilsson, B
    Fernández-Varea, JM
    Andreo, P
    PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (10): : 1263 - 1275
  • [3] A code for the automatic Monte Carlo simulation of linacs using PENELOPE
    Brualla, L.
    Sauerwein, W.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2009, 185 : 50 - 50
  • [4] Experimental benchmarks of the Monte Carlo code PENELOPE
    Sempau, J
    Fernández-Varea, JM
    Acosta, E
    Salvat, F
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2003, 207 (02): : 107 - 123
  • [5] A COMPUTATIONAL MODEL FOR STRONTIUM-90 DOSIMETRY IN CHRONICALLY EXPOSED BEAGLE
    POWELL, TJ
    GOLDMAN, M
    HEALTH PHYSICS, 1965, 11 (08): : 816 - +
  • [6] The measuring and modelling of strontium-90: An integrated retrospective dosimetry issue
    Degteva, MO
    Kozheurov, VP
    Tolstykh, EI
    Kovtun, AN
    IRPA9 - 1996 INTERNATIONAL CONGRESS ON RADIATION PROTECTION / NINTH INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, PROCEEDINGS, VOL 1, 1996, : A417 - A424
  • [7] Implementation of Detailed Monte Carlo Simulation for Semiconductor Detectors Using the PENELOPE Code
    Mendes, H.
    Tomal, A.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [8] Dosimetric Modeling of Mammography Using the Monte Carlo Code PENELOPE and Its Validation
    Tse, Jason
    Fulton, Roger
    McLean, Donald
    BREAST IMAGING, IWDM 2016, 2016, 9699 : 160 - 166
  • [9] Modeling energy deposition in trabecular spongiosa using the Monte Carlo code Penelope
    Gersh, Jacob A.
    Dingfelder, Michael
    Toburen, Larry H.
    HEALTH PHYSICS, 2007, 93 (01): : 47 - 59
  • [10] Dosimetry of Strontium eye applicator: Comparison of Monte Carlo calculations and radiochromic film measurements
    Laoues, M.
    Khelifi, R.
    Moussa, A. S.
    8TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2015, 573