Cellular dosimetry calculations for Strontium-90 using Monte Carlo code PENELOPE

被引:3
|
作者
Hocine, Nora [1 ]
Farlay, Delphine [2 ,3 ]
Boivin, Georges [2 ,3 ]
Franck, Didier [1 ]
Agarande, Michelle [1 ]
机构
[1] Inst Radioprotect & Surete Nucl, Lyon, France
[2] INSERM UMR 1033, Lyon, France
[3] Univ Lyon, Lyon, France
关键词
PENELOPE; MCNPX; MIRD; Sr-90; validation; cellular dosimetry; TRANSPORT; PHOTON;
D O I
10.3109/09553002.2014.955144
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose: To improve risk assessments associated with chronic exposure to Strontium-90 (Sr-90), for both the environment and human health, it is necessary to know the energy distribution in specific cells or tissue. Monte Carlo (MC) simulation codes are extremely useful tools for calculating deposition energy. The present work was focused on the validation of the MC code PENetration and Energy LOss of Positrons and Electrons (PENELOPE) and the assessment of dose distribution to bone marrow cells from punctual Sr-90 source localized within the cortical bone part. Materials and methods: S-values (absorbed dose per unit cumulated activity) calculations using Monte Carlo simulations were performed by using PENELOPE and Monte Carlo N-Particle eXtended (MCNPX). Cytoplasm, nucleus, cell surface, mouse femur bone and Sr-90 radiation source were simulated. Cells are assumed to be spherical with the radii of the cell and cell nucleus ranging from 2-10 mm. The Sr-90 source is assumed to be uniformly distributed in cell nucleus, cytoplasm and cell surface. Results: The comparison of S-values calculated with PENELOPE to MCNPX results and the Medical Internal Radiation Dose (MIRD) values agreed very well since the relative deviations were less than 4.5%. The dose distribution to mouse bone marrow cells showed that the cells localized near the cortical part received the maximum dose. Conclusion: The MC code PENELOPE may prove useful for cellular dosimetry involving radiation transport through materials other than water, or for complex distributions of radionuclides and geometries.
引用
收藏
页码:953 / 958
页数:6
相关论文
共 50 条
  • [31] Case studies - Internal dosimetry calculations using Markov chain Monte Carlo
    Miller, G
    PRACTICAL APPLICATIONS OF INTERNAL DOSIMETRY, 2002, : 353 - 388
  • [32] Technological developments for strontium-90 determination using AMS
    Satou, Yukihiko
    Sueki, Keisuke
    Sasa, Kimikazu
    Matsunaka, Tetsuya
    Takahashi, Tsutomu
    Shibayama, Nao
    Izumi, Daiki
    Kinoshita, Norikazu
    Matsuzaki, Hiroyuki
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2015, 361 : 233 - 236
  • [33] PENLINAC:: extending the capabilities of the Monte Carlo code PENELOPE for the simulation of therapeutic beams
    Rodriguez, M. L.
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (17): : 4573 - 4593
  • [34] Monte Carlo simulation of MOSFET detectors for high-energy photon beams using the PENELOPE code
    Panettieri, Vanessa
    Duch, Maria Amor
    Jornet, Nuria
    Ginjaume, Merce
    Carrasco, Pablo
    Badal, Andreu
    Ortega, Xavier
    Ribas, Montserrat
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (01): : 303 - 316
  • [35] Monte Carlo simulation of X-ray emission using the general-purpose code PENELOPE
    Llovet, X
    Fernández-Varea, JM
    Sempau, J
    Salvat, F
    SURFACE AND INTERFACE ANALYSIS, 2005, 37 (11) : 1054 - 1058
  • [36] Cellular Dosimetry Using the Geant4 Monte Carlo Toolkit REPLY
    Cai, Zhongli
    Pignol, Jean-Philippe
    Chan, Conrad
    Reilly, Raymond M.
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (09) : 1489 - 1489
  • [37] Coincidence summing corrections using PENELOPE/PENNUC Monte Carlo code for volume sources of different densities
    Salpadimos, N.
    Karfopoulos, K.
    Potiriadis, C.
    Seimenis, I.
    APPLIED RADIATION AND ISOTOPES, 2023, 192
  • [38] Dosimetry of small radiation field in inhomogeneous medium using alanine/EPR minidosimeters and PENELOPE Monte Carlo simulation
    Vega Ramirez, J. L.
    Chen, F.
    Nicolucci, P.
    Baffa, O.
    RADIATION MEASUREMENTS, 2011, 46 (09) : 941 - 944
  • [39] Calibration of strontium-90 eye applicator using a strontium external beam standard
    Siddle, D
    Langmack, K
    PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (07): : 1597 - 1608
  • [40] A NEW MONTE CARLO CODE FOR NUCLEAR CRITICALITY CALCULATIONS
    Huayun, Shen
    Kan, Wang
    ICONE16: PROCEEDING OF THE 16TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2008, VOL 2, 2008, : 497 - 500